Cylindrical M18 photoelectric sensor for AC power supply
E3F2-@Z
• 24 to 240 VAC power supply
• UL and CSA approved
Selection Guide
Housing material: Plastic
Sensing method
Throughbeam
Retroreflective
Diffuse
reflective
Note: Standard cable length is 2 m. Models provided with a 5 m long cable are available. When ordering, specify the cable length by adding the length of the cable
(e.g. E3F2-R2Z1 2M or E3F2-R2Z1 5M). For other cable length please contact your OMRON sales representative.
Non-polarizing
(without MSR function)
Fixed sensing distance
Wide-beam characteristics
Appearance Connection Sensing Model
method distance Light-ON Dark-ON
axial
axial
axial
pre-wired 3 m E3F2-3Z1 E3F2-3Z2
pre-wired
pre-wired 0.1 m E3F2-DS10Z1-N E3F2-DS10Z2-N
0.1 - 2 m
(with
reflector
E39-R1)
E3F2-R2Z1-E E3F2-R2Z2-E
Ordering Information: type list
Model
E3F2-3LZ 2M Through-beam, 3 m axial Pre-wired (2 m)* N.A. Emitter only
E3F2-3DZ1 2M Through-beam, 3 m axial Pre-wired (2 m)* Light-ON Receiver only
E3F2-3DZ2 2M Through-beam, 3 m axial Pre-wired (2 m)* Dark-ON Receiver only
E3F2-3Z1 2M Through-beam, 3 m axial Pre-wired (2 m)* Light-ON Receiver and Emitter
E3F2-3Z2 2M Through-beam, 3 m axial Pre-wired (2 m)* Dark-ON Receiver and Emitter
E3F2-R2Z1 2M Retroreflective, 2 m axial Pre-wired (2 m)* Light-ON Non-polarizing, incl. E39-R1
E3F2-R2Z2 2M Retroreflective, 2 m axial Pre-wired (2 m)* Dark-ON Non-polarizing, incl. E39-R1
E3F2-R2Z1-E 2M Retroreflective, 2 m axial Pre-wired (2 m)* Light-ON Non-polarizing, including reflector
E3F2-R2Z2-E 2M Retroreflective, 2 m axial Pre-wired (2 m)* Dark-ON Non-polarizing, including reflector
E3F2-DS10Z1-N 2M Diffuse reflective, 0.1 m axial Pre-wired (2 m)* Light-ON Wide-beam characteristic
E3F2-DS10Z2-N 2M Diffuse reflective, 0.1 m axial Pre-wired (2 m)* Dark-ON Wide-beam characteristic
Sensing method,
sensing range
Appearance
Connection
(cable-length)
Control
output
Comments
* Standard cable length is 2 m. Models provided with a 5 m long cable are available. When ordering, specify the cable length by adding the length of the cable
(e.g. E3F2-R2Z1 2M or E3F2-R2Z1 5M). For other cable length please contact your OMRON sales representative.
1E3F2-@Z
Specifications
Ratings / Characteristics of AC Switching Models
Item
E3F2-3Z1
E3F2-3Z2
Sensing method Through-beam Non-polarizing Retroreflective
E3F2-R2Z1
E3F2-R2Z2
E3F2-DS10Z1
E3F2-DS10Z2
Diffuse reflective
(wide-beam characteristic)
Power supply voltage 24 to 240 VAC ±10 %, 50 / 60 Hz
Current consumption 10 mA max. 5 mA max.
Rated sensing distance
Typical sensing distance for different reflector types
*1
*2
3 m
0.1 - 2 m
(with reflector E39-R1)
(5 x 5 cm white mat paper)
E39-R1: 3,4 m
–
E39-R7: 3,9 m
E39-R8: 5,2 m
0.1 m
–
Detectable object Opaque object: 11 mm min. Opaque object: 56 mm min. Opaque objects
Directional angle 3° to 20° –
Differential travel – 20 % max.
Response time 30 ms max.
Control output AC solid state (SCR) 200 mA max.; residual voltage: 5 V max. at 200 mA
Power reset time 100 ms
Ambient illumination Incandescent lamp: 3000 lx max. Sunlight: 10000 lx max.
Ambient temperature
*3
Operating: -25 to 55 °C / Storage: -30 to 70 °C (with no icing or condensation)
Ambient humidity Operating: 35% to 85% / Storage: 35% to 95% (without condensation)
Insulation resistance 20 M min. at 500 V DC between energized parts and case
Dielectric strength 1500 VAC, 50 / 60 Hz for 1 min between energized parts and case
Vibration resistance 10 to 55 Hz, 1.5 mm double amplitude for 2 hrs each direction (X, Y, Z)
Shock resistance 500 m/sqr (approx. 50 g) for each direction (X, Y, Z)
Enclosure rating
*4
; NEMA 1, 2, 4; IP69k after DIN 40050 part 9
IP67
Light source Infrared LED (880 nm)
Indicators Light incident/power indicator for light source (red)
Sensitivity adjustment Fixed
Connection method
2 m, 5 m pre-wired cable (PVC dia. 4 mm (14 / 0.15)
*5
)
Operation mode Light-ON or Dark-ON (fixed)
Circuit protection None
Weight (approx.) 110 g (pre-wired 2 m cable)
Housing materials Plastic (case: ABS; lens: PMMA)
*1
For stable sensing distance in detail, please refer to ”Engineering Data”
*2
Typical sensing distance corresponds to 80 % of the max. sensing distance.
*3
*4
The enclosure rating IP67 of OMRON internal standards correspond to stricter test requirements than the standard IEC 60529 (refer to chapter “Precautions”)
*5
For other cable materials (e.g. PUR) please contact your OMRON sales representative.
2 Standard Photoelectric Sensors