Inductive Proximity Sensor
E2KQ-X
Proximity Sensor with Easy Sensing
Distance Adjustment and Teflon* Coating
Effective Oil and Chemical Resistance
• Oil and chemical-resistant Teflon case.
• Sensitivity adjuster ensures easy sensing distance
adjustment according to the sensing object.
• Incorporates a cord connector with an indicator providing high visibility.
* Teflon is a registered trademark of Dupont Company and Mitsui Du-
pont Chemical Company for their fluoride resin.
Ordering Information
Shape Sensing distance Output
Unshielded
M18
* NC models available (E2KQ-X10ME2)
6 to
10 mm
Characteristic data (typical)
Sensing Distance vs. Sensing Object
15
#d
t
mm
=3
X
10
Sensing distance X (mm)
5
0
0 1020304050607080
Side length of sensing object d (mm)
Grounded metal
Ungrounded metal
Glass
Phenol resin
DC 3-wire
NPN
Operating
status
NO *
Model
E2KQ-X10ME1
Sensing Object Thickness and Material vs. Sensing Distance
15
#
50
t
X
10
Sensing distance X (mm)
5
0
0 5 10 15 20 25 30
Grounded metal
Ungrounded metal
Glass
Phenol resin
Wooden plate
Acrylic resin
Sensing object width t (mm)
E2KQ-X
D-179E2KQ-X

Output Circuit Diagram
DC 3-wire Models
Operating
status
NO
Model Timing chart Output circuit
E2KQ-X10ME1
Rating/Performance
Sensing object
Load
(between brown
and black)
Output voltage
(between black
and blue)
Operation indicator
(red)
Operates
Releases
OFF
Yes
ON
Brown
No
Main
H
L
circuit
* 1. 100 mA max. (load current)
* 2. When a transistor is connected
4.7kW
Black * 1
Output
Blue
+V
Load
* 2
Tr
0V
Item
Sensing distance *
Model
10 mm
E2KQ-X
Sensing distance adjustable range 6 to 10 mm
Differential distance 4% to 20% of sensing distance
Sensing object Conductors and dielectrics
Standard sensing object with grounded metal: 50 x 50 x 1t mm
Response frequency
Rated supply voltage
(operating voltage)
35 Hz
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
Current consumption 15 mA max.
Control output
Switching capacity
Residual voltage 1.5 V max. (under load current of 100 mA with cable length of 2 m)
100 mA
Indicator lamp Detection indicator (red LED)
Operating status
(with sensing object approaching)
Refer to previous pages for details of operating chart of output circuits.
Protective circuits Reverse connection protection, surge absorber
Ambient temperature Operating: -10°C to 55°C, Storage: -25°C to 55°C (with no icing or condensation)
Ambient humidity Operating/Storage: 35% to 85%RH (with no condensation)
Temperature influence ±15% max. of sensing distance at 23°C in the temperature range of -10°C and 55°C
Voltage influence 2% max. sensing distance within a range of 80% to 120% of the rated supply voltage.
Insulation resistance 50 M min. (at 500 VDC) between energized parts and case
Dielectric strength 500 VAC 50/60 Hz for 1 min between energized part and case
Vibration resistance 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance Destruction: 500 m/s2 for 3 times each in X, Y, and Z directions
Protective structure IEC IP66
Connection method Pre-wired models (standard length: 2 m)
Weight (Packed state) Approx. 150 g
Case, Sensing
Material
surface
Fluororesin
Clamping nut
Accessories Instruction sheet and screwdriver for adjustment
* This sensing distance is possible with a standard sensing object. Refer to Engineering Data for sensing distances of other materials.
D-180 Capacitive Sensors