Omron E2K-L13MC1, E2K-L26MC1 Applications

D-203E2K-L
E2K-L
Liquid Level Sensor
E2K-L
• Installation on pipes.
• Sensing by means electrostatic capacity and is not influenced by the color of the pipe or liquid.
• Built-in amplifier for space-saving.
Applications
Ordering Information
Liquid surface level detection
Sensor type Applicable pipe diameters Shape Output form Model
Electrostatic
capacity method
8 to 11 mm dia.
NPN open-collector out­put
NO
E2K-L13MC1
12 to 26 mm dia.
E2K-L26MC1
D-204 Capacitive Sensors
Rating/Performance
Note: In the following cases, stable detection may not be possible and ensure to confirm correct operation in the actual installation before use.
1 .If the dielectric constant or conductivity of the liquid is low. 2 .If the capacity of the liquid is small, or if the pipe diameter is so small or the pipe walls are so thick that the amount by which the capacity changes relating to
the liquid level is small.
3 .In case of an increased gassing or a highly viscous liquid firm residue on the inside walls of the pipe, or a dirt clogging on the inner or outer walls of the pipe.
Item Model E2K-L13MC1 E2K-L26MC1
Applicable pipes
Material
Non-metal
Size
External diameter
8 to 11 mm dia. 12 to 26 mm dia.
Wall thickness
1 mm max. 1.5 mm max.
Sensing object Liquid (see note) Repetition precision
±0.2 mm max.
Response difference
0.6 to 5 mm 0.3 to 3 mm
(reference value only; varies with pipe size and solution)
Supply voltage (operating voltage range)
12 to 24 VDC, 10% max. ripple (10.8 to 30 VDC)
Current consumption 12 mA max.
Control output
Switching capacity
100 mA max.
Residual voltage
1 V max. (under load current of 100 mA with cable length of 2 m)
Detection position of liquid surface
Notch position (For details, refer to Sensitivity Adjustment on next page.) Indicator lamp Operation indicator (orange) Ambient temperature Operating: 0 to 55°C; Storage: -10 to 65°C (with no icing or condensation) Ambient humidity Operating/storage: 25% to 85% (with no condensation)
Temperature influence
In the range 0 to 55°C: Detection level at 23°C 4 mm (with distilled water or 20 % salt water con­centration)
(±6 mm with E2K-L13MC1 for distilled water in pipe of 8 mm diameter) Voltage influence At the rated power supply voltage ±10%: Detection level at rated supply voltage ±0.5 mm Insulation resistance 50 M min. (at 500 VDC) between energized parts and case Dielectric strength 500 VAC 50/60 Hz for 1 min between energized part and case Vibration resistance 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions Shock resistance 500 m/s2 for 3 times each in X, Y, and Z directions Protective structure IEC 60529 IP66 Connection method Pre-wired models (standard length: 2 m) Weight (Packed state) Approx. 70 g
Material
Case, cover
Heat-resistant ABS resin
Cable clamp
NBR
Accessories 2 binding bands, 4 nonskid tubes, instruction manual