Long-distance Capacitive Proximity Sensor
E2K-C
Capacitive Proximity Sensor
with Adjustable Sensitivity
• Detects both metallic and non-metallic objects (glass,
lumber, water, oil, plastic, etc.) without direct contact.
• DC models acquire CE marking
Ordering Information
Sensors
Shape Sensing distance
Unshielded
34 dia.
3 to 25mm
Output specifications
DC 3-wire NPN
DC 3-wire PNP
Model
Operating status
NO NC
E2K-C25ME1
E2-KC25MF1
E2K-C25ME2
E2K-C25MF2
Accessories (Order Separately)
Mounting Brackets
Shape Model Quantity Remarks
Y92E-A34 1 Supplied with the product.
E2K-C
D-183E2K-C
Rating/Performance
Item Model E2K-C25M#1 E2K-C25M#2
Sensing distance * 25 mm
Sensing distance
adjustable range
Sensing object Conductors and dielectrics
Standard sensing object with grounded metal: 50 x 50 x 1t mm
Differential distance 15% max. of sensing distance (when adjusted to 25 mm ±10% with standard object)
Response frequency
Power supply(Operating
voltage range)
Current consumption E models: 10 mA max. at 12 VDC, 16 mA max. at 24 VDC
Leakage current
Switching
Control
output
Indicator lamp Detection indicator (red LED)
Operating status
(with sensing object
approaching)
Protective circuits Reverse connection protection, surge absorber
Ambient temperature Operating/Storage: -25°C to 70°C (with no icing or condensation)
Ambient humidity Operating/Storage: 35% to 95%RH (with no condensation)
Temperature influence ±15%max. of sensing distance at 23° within temperature range -10°C to 55°C
Voltage influence ±2% max. of sensing distance at a voltage between 85% and 115% of the rated power supply voltage
Insulation resistance 50 M min. (at 500 VDC) between current carry parts and case
Dielectric strength
Vibration resistance 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance Destruction: 500 m/s2 for 10 times each in X, Y, and Z directions
Protective structure IEC 60529 IP66
Connection method Pre-wired models (standard length: 2 m)
Weight (Packed state) Approx. 200 g
Material
Accessories Mounting bracket, instruction manual
* The set distances are sensing distances applicable to standard sensing objects. Refer to Engineering Data for sensing distances applicable to other types of objects.
capacity
Residual
voltage
Case
Sensing
surface
3 to 25 mm
70 Hz
12 to 24 VDC, ripple (p-p): 10% max.,(10 to 40 VDC)
Y models: 1 mA max. at 100 VAC (50/60 Hz) with output turned OFF., 2 mA max. at 200 VAC (50/60 Hz)
with output turned OFF.
200 mA max.
2 V max. (under load current of 200 mA with cable length of 2 m)
E1, Y1 models: NO
E2, Y2 models: NC
1000 VAC 50/60 Hz for 1 min
between energized part and case
Heat-resistant ABS resin
D-184 Capacitive Sensors