2 Inductive Sensors
Rating/Performance
Item Model E2FQ-X2@ E2FQ-X5@ E2FQ-X10@
Sensing distance 2 mm ±10% 5 mm ±10% 10 mm ±10%
Setting distance 0 to 1.6 mm 0 to 4 mm 0 to 8 mm
Differential distance E1, F1 models: 10% max. of sensing distance
Sensing object Ferrous metal (Sensitivity lowers with non-ferrous metals)
Standard sensing object
(mild steel)
12 x 12 x 1 mm 18 x 18 x 1 mm 30 x 30 x 1 mm
Response frequency*1
*1. The response frequencies are average values measured on condition that the distance between each sensing object is twice as large as the size of the sensing
object and the sensing distance set is half of the maximum sensing distance.
E1, F1 models: 1.5 kHz
D1 models: 800 Hz
E1, F1 models: 600 Hz,
D1 models: 500 Hz
E1, F1 models: 400 Hz,
D1 models: 300 Hz
Power supply
(Operating voltage
range)
E1, F1 models: 12 to 24 VDC, ripple (p-p) : 10% max., (10 to 30 VDC)
D1 models: 12 to 24 VDC, ripple (p-p) : 20% max., (10 to 36 VDC)
Current consumption E1, F1 models: 17 mA max.
Leakage current D1 models: 0.8 mA max.
Control
output
Switching
capacity
E1, F1 models: 200 mA max., D1 models: 5 to 100 mA DC
Residual
voltage
E1, F1 models: 2 V max. (load current: 200 mA with cable length: 2 m)
D1 models: 4.0 V max. (under load current of 100 mA with cable length of 2 m)
Indicator lamp E,D models: detection indicator (red)
Operating status
(with sensing object
approaching)
Normally open (NO)
Protective circuits E1, F1 models: Protection for reverse polarity, load short circuit, surge voltage
Ambient temperature Operating/Storage: -25°C to 70°C (with no icing or condensation)
Ambient humidity Operating/Storage: 35% to 95%RH (with no condensation)
Temperature influence 10% max. of sensing distance at 23°C within temperature range of -25°C to 70°C
Voltage influence E1, F1 models: ±2.5% max. of sensing distance within rated voltage range ±15%
Insulation resistance 50 MW min. (at 500 VDC) between energized parts and case
Dielectric strength E1, F1, D1 models: 1,000 VAC 50/60 Hz for 1 min between energized parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
Destruction: 500 m/s
2
for 10 times
each in X, Y, and Z directions
Destruction: 1,000 m/s
2
for 10 times each in X, Y, and Z directions
Protective structure IEC60529 IP67
Connection method Pre-wired models (standard length: 2 m)
Weight (Packed state) Approx. 70 g Approx. 130 g Approx. 170 g
Material
Case
Fluoro plastic
Sensing
surface
Accessories Instruction manual