*1. Please contact your OMRON representative for DC 2-wire models.
*2. Stainless steel models are also available. Please contact your OMRON representative.
Note:M30 non-shielded models with double sensing distance and short barrels cannot be mounted due to the necessary separation distance from the surrounding
metal. Standard sensing models are thus available.
D-9E2AX
Connectivity
The E2A sensors are available with the following connectors:
Connector models
Standard connectors: M12-M1
Model Number Legend
E2A@-@@@@@-@-@@-@@
2 3 4 5 6 7 8 9 10 11112
Example: E2A-M12LS04-M1-B1Standard, M12, long barrel, shielded, Sn=4 mm, M12 connector, PNP-NO
1. Basic name
2. Sensing technology
3. Housing shape and material
4. Housing size
5. Barrel length
6. Shield
7. Sensing distance
E2A-S08KN04-WP-B1 5MStandard, M8 stainless steel, short barrel, non-shielded, Sn=4 mm, pre-wired PVC cable, PNP-NO,
Note: *In case of DC 2-wire models the M12 connector identifier is '-M1G'
D-10Inductive Sensors
Specifications
DC 3-wire Models / DC 4-wire (NO+NC)
SizeM12
Typ eShieldedNon-shielded
E2AX-M12@S04-@@-B
E2AX-M12@S04-@@-C
Item
Sensing distance4 mm ± 10%8 mm ± 10%
Setting distance0 to 3.2 mm0 to 6.4 mm
Differential travel10% max. of sensing distance
TargetFerrous metal (The sensing distance decreases with non-ferrous metal.)
Standard target (mild steel ST37)12×12×1 mm24×24×1 mm
Response frequency (See note 1.)1,000 Hz800 Hz
Power supply voltage
(operating voltage range)
Current consumption (DC 3-wire)10 mA max.
Output type
Control
output
IndicatorOperation indicator (Yellow LED)
Operation mode
(with sensing object approaching)
Protection circuit
Ambient air temperatureOperating: −40°C to 70°C, Storage: −40°C to 85°C (with no icing or condensation)
Temperature influence (See note 2.)
Ambient humidityOperating: 35% to 95%, Storage: 35% to 95%
Voltage influence±1% max. of sensing distance in rated voltage range ±15%
Insulation resistance50 MΩ min. (at 500 VDC) between current carry parts and case
Dielectric strength1,000 VAC at 50/60 Hz for 1 min between current carry parts and case
Vibration resistance10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance
Standard and listings (See note 3.)
Connection methodPlease see chapter ’Connectivity’ for details on M12 connectors.
Weight
(packaged)
Material
Note 1. The response frequency is an average value. Measurement conditions are as follows: standard target, a distance of twice the standard
target distance between targets, and a setting distance of half the sensing distance.
2. When using any model at an ambient temperature between −40°C and −25°C and a power voltage between 30 and 32 VDC, use a load
current of 100 mA max.,
3. For USA and Canada: Use class 2 circuit only.
Load current
(See note 2.)
Residual voltage2 V max. (under load current of 200 mA with cable length of 2 m)
Connector modelApprox. 35 g
CaseBrass-nickel plated or stainless steel
Sensing surfacePBT
Clamping nutBrass-nickel plated for brass models stainless steel for steel models
12 to 24 VDC. Ripple (p-p): 10% max.
(10 to 32 VDC)
-B models: PNP open collector
-C models: NPN open collector
200 mA max. (32 VDC max.)
-B1/-C1 models: NO
-B2/-C2 models: NC
-B3/ -C3 models: NO+NC
For details, refer to the timing charts.
±10% max. of sensing distance at 23°C within temperature range of −25°C to 70°C
±15% max. of sensing distance at 23°C within temperature range of −40°C to 70°C
Typ eShieldedNon-shieldedShieldedNon-shieldedNon-shielded
E2AX-M18@S08-M1-B@
E2AX-M18@S08-M1-C@
Item
E2AX-S18@S08-M1-B@
E2AX-S18@S08-M1-C@
Sensing distance8 mm±10%16 mm±10%15 mm±10%20 mm±10%30 mm±10%
Setting distance0 to 6.4 mm0 to 12.8 mm0 to 12 mm0 to 16 mm0 to 24 mm
Differential travel10% max. of sensing distance
TargetFerrous metal (The sensing distance decreases with non-ferrous metal.)
Standard target
(mild steel ST37)
Response frequency
(See note 1.)
Power supply voltage
(operating voltage range)
Current consumption
(DC 3-wire)
Output type
Control
output
Load current
(See note 2.)
Residual voltage2 V max. (under load current of 200 mA with cable length of 2 m)
24×24×1 mm48×48×1 mm45×45×1 mm60×60×1 mm90×90×1 mm
500 Hz400 Hz250 Hz100 Hz100 Hz
12 to 24 VDC. Ripple (p-p): 10% max.
(10 to 32 VDC)
10 mA max.
-B models: PNP open collector
-C models: NPN open collector
200 mA max. (32 VDC max.)
IndicatorOperation indicator (Yellow LED)
Operation mode
(with sensing object
approaching)
Protection circuit
-B1/-C1 models: NO
-B2/-C2 models: NC
-B3/ -C3 models: NO+NC
For details, refer to the timing charts.
Short-circuit protection
Ambient air temperatureOperating: −40°C to 70°C, Storage: −40°C to 85°C (with no icing or condensation)
Temperature influence
(See note 2.)
±10% max. of sensing distance at 23°C within temperature range of −25°C to 70°C
±15% max. of sensing distance at 23°C within temperature range of −40
Ambient humidityOperating: 35% to 95%, Storage: 35% to 95%
Voltage influence±1% max. of sensing distance in rated voltage range ±15%
Insulation resistance50 MΩ min. (at 500 VDC) between current carry parts and case
Dielectric strength1,000 VAC at 50/60 Hz for 1 min between current carry parts and case
Vibration resistance10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance
Standard and listings
(See note 3.)
1,000 m/s
IP65
EMC after EN60947-5-2
ATEX after EN50014
2
, 10 times each in X, Y and Z directions
EN50281-1-1/2
Connection methodPlease see chapter 'Connectivity' for details on M12 connectors.
Weight
(pak-
Connector modelApprox. 70 gApprox. 200 gApprox. 200 gApprox. 260 g
kaged)
CaseBrass-nickel plated or stainless steel
Material
Sensing surfacePBT
Clamping nutbrass-nickel plated for brass models stainless steel for steel models
Note 1. The response frequency is an average value. Measurement conditions are as follows: standard target, a distance of twice the standard
target distance between targets, and a setting distance of half the sensing distance.
2. When using any model at an ambient temperature between −40°C and −25°C and a power voltage between 30 and 32 VDC, use a load
current of 100 mA max.
Sensing distance4 mm ± 10%8 mm ± 10%
Setting distance0 to 3.2 mm0 to 6.4 mm
Differential travel10% max. of sensing distance
TargetFerrous metal (The sensing distance decreases with non-ferrous metal.)
Standard target12×12×1 mm24×24×1 mm
Response frequency (See note 1.)1,000 Hz800 Hz
Power supply voltage
(operating voltage range)
Leakage current0.8 mA max.
Output typeDC 2 wire type
Control
output
Indicator (see timing chart)
Operation mode
Protection circuitSurget suppressor, Short circuit protection
Ambient temperatureOperating: −40°C to 70°C, Storage: −40°C to 85°C (with no icing or condensation)
Temperature influence
Ambient humidityOperating: 35% to 95%, Storage: 35% to 95%
Voltage influence±1% max. of sensing distance in rated voltage range ±15%
Insulation resistance50 MΩ min. (at 500 VDC) between current carry parts and case
Dielectric strength1,000 VAC at 50/60 Hz for 1 min between current carry parts and case
Vibration resistance10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance
Standard and listings (See note 3.)
Connection method
Weight
(packaged)
Material
Note 1. The response frequency is an average value. Measurement conditions are as follows: standard target, a distance of twice the standard
target distance between targets, and a setting distance of half the sensing distance.
2. When using any model at an ambient temperature between −40°C and −25°C and a power voltage between 30 and 32 VDC, use a load
current of 50 mA max.
3. For USA and Canada: Use class 2 circuit only.
Load current
(See note 2.)
Residual voltage3 V max. (under load current of 100 mA with cable length of 2 m)
Pre-wired modelApprox. 85 g
Connector modelApprox. 35 g
CaseBrass-nickel plated or stainless steel
Sensing surfacePBT
Clamping nutBrass-nickel plated for brass models stainless steel for steel models
12 to 24 VDC. Ripple (p-p): 10% max.
(10 to 32 VDC)
±10% max. of sensing distance at 23°C within temperature range of −25°C to 70°C
±15% max. of sensing distance at 23°C within temperature range of −40°C to 70°C
1,000 m/s
IP65
EMC after EN60947-5-2
ATEX after EN50014
Please see chapter 'Connectivity' for details on different cable materials and lenghts and M8 or M12
connectors.
E2AX-M12@S04-D
E2AX-S12@S04-D
2
, 10 times each in X, Y and Z directions
EN50281-1-1/2
@
@
E2AX-M12@N08-D
E2AX-S12@N08-D
@
@
E2AX
D-13E2AX
Loading...
+ 9 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.