Omron CX-POSITIO DATASHEET

WS02-NCTC1-E
CX-Position
Set, transfer, store, and print position control unit data and monitor operation online
Increase productivity in all position control tasks, from design and startup to system maintenance.
Key Features
The CX-Position software simplifies every aspect of position control, from creating/editing the data used in Position Control Units (NC Units) to communicating online and monitoring operation. The software is equipped with functions that can improve productivity, such as automatically generating project data and reusing existing data.
Creating and managing data
Data can be created for various applications
The CX-Position enables data for multiple NC Units on up to 1,000 PLCs to be handled as 1 project. Data is displayed in tree format and the data for an NC Unit can be moved or copied (overwritten) between PLCs in the project tree. This feature allows data to be edited and re-used in other PLCs or NC
Units.
The CX-Position can read information from NC Units connected online and automatically generate project data.
Data created for a C200HW-NC@@@ using the SYSMAC-NCT can be imported and used as data for the CS1W-NC@@@ or CJS1W-NC@@@.
NC Monitor
Display the NC units’ present positions, error codes, sequence numbers, and I/O status.
The sequence numbers and present positions can be dis-played for up to 4 Units. In addition, the contents of the operating memory area and operating data area can be monitored and the error log can be displayed.
System Configuration with CS1W-NC413/433
CX-Programmer
Creation and transfer of ladder programs, monitoring, file
NC Unit (CS1W-NC413/433)
External inputs
CCW limit input CW limit input Origin input
Emergency stop input
Interrupt input
Interface power supply (24 V)
Stepping motor
drivers
Stepping motorsorServo motors
CPU Unit (CS1 Series)
Servomotor drivers
management, etc.
Power Supply Unit
Peripheral bus/Host Link
External inputs
Stepping motors Servo motors
CCW limit input CW limit input Origin input
Emergency stop input
Interrupt input
Interface power supply (24 V)
or
Stepping motor
drivers
CX-Position
Creation and transfer of data, NC Unit monitoring, file management, etc.
Servomotor drivers
Software
Communications
Communicate with NC units through the network.
It is possible to communicate with NC Units through the Fins-Gateway. Depending on the FinsGateway driver version, HostLink or Ethernet. can be used to perform online operations (monitoring operation or transferring/verifying parameters,sequences, etc.) with the NC Unit.
Specifications
Compatible Position Control Units:
Basic Functions
Created files
CS Series:CS1W-NC113/NC133/NC213/NC413/NC433 CJ Series: CJ1W-NC113/NC133/NC213/NC413/NC433
Create, edit, and print the Position Control Unit’s parameter data,sequence data, speed data, acceleration/deceleration data, dwell times, and zone data. Monitor the Position Control Unit’s operating status.
CX-Position project files (*.nci) Contents: Parameter data, sequence data, speed data, acceleration/deceleration data, dwell times, and zone data
Operating Environment
CPU:
OS:
Pentium 100 MHz or faster CPU
Windows 95, 98, NT4.0, W2000 or XP
Compatible PLCs:
CS Series and CJ Series
289CX-Position
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. I26E-EN-01
In the interest of product improvement, specifications are subject to change without notice.
290 Software