Omron BP761, BP761CAN Instruction Manual

Page 1
English
Español
Page 2
Monitor
Battery Set
ComFit™ Cuff
El producto incluye:
Monitor
Juego de Pilas
Brazalete ComFit™
Product includes:
Page 3
Contents
Thank you for purchasing the OMRON® BP761 Blood Pressure Monitor.
Your new blood pressure monitor uses the oscillometric method of blood pressure measurement. This means the monitor detects your blood movement through your brachial artery and converts the movements into a digital reading. An oscillometric monitor does not need a stethoscope so the monitor is simple to use.
Intended Use
This device is a digital monitor intended for use in measuring blood pressure and pulse rate in adult patient population. The device detects the appearance of irregular heartbeats during measurement and gives a warning signal with the measurement result.
Important Safety Information........................1
1. Know Your Device....................................4
1.1 Display Symbols.....................................5
1.2 Before Taking a Measurement...............6
2. Preparation ...............................................7
2.1 Battery Installation..................................7
2.2 Setting the Date and Time .....................8
4. Error Messages and Troubleshooting... 20
4.1 Error Messages ................................... 20
4.2 Troubleshooting................................... 22
5. Maintenance and Storage......................23
5.1 Maintenance ........................................ 23
5.2 Storage................................................ 24
5.3 Optional Medical Accessories ............. 25
Page 4
EN
Important Safety Information
Warning: Indicates a potentially hazardous situation which, if not avoided, could result in death or
serious injury.
(General Usage)
DO NOT adjust medication based on measurement results from this blood pressure monitor. Take medication as prescribed by your physician. Only a physician is qualified to diagnose and treat High Blood Pressure. The monitor is not intended to be a diagnostic device. Consult your physician before using the device for any of the following conditions: common arrhythmias such as atrial or ventricular premature beats or atrial fibrillation, arterial sclerosis, poor perfusion, diabetes, age, pregnancy, pre-eclampsia, renal diseases. Note that PATIENT motion, trembling, shivering may affect the measurement reading. Do not use the device on the injured arm or the arm under medical treatment. Do not apply the arm cuff on the arm while on an intravenous drip or blood transfusion. Consult your physician before using the device on the arm with an arterio-venous (A-V) shunt. Do not use the device with other medical electrical (ME) equipment simultaneously. Do not use the device in the area of HF surgical equipment, MRI, or CT scanner, or in an oxygen rich environment. The air tube or the AC adapter cable may cause accidental strangulation in infants. Contains small parts that may cause a choking hazard if swallowed by infants.
(Data Transmission)
Do not use this product on aircraft or in hospitals. Please remove the battery and AC adapter from the unit. This
Page 5
Important Safety Information
Caution: Indicates a potentially hazardous situation which, if not avoided, may result in minor or
moderate injury to the user or patient or damage to the equipment or other property.
(General Usage)
Always consult your physician. Self-diagnosis of measurement results and self-treatment are dangerous. Consult your physician before using the device for any of the following conditions:
• If you have had a mastectomy.
• Do not take measurements more than necessary. It may cause bruising due to blood flow interference.
• People with severe blood flow problems or blood disorders as cuff inflation can cause bruising. Remove the arm cuff if it does not start deflating during the measurement.
Do not use this device on infants or persons who cannot express their intentions. Do not use the device for any purpose other than measuring blood pressure. Use only the approved arm cuff for this device. Use of other arm cuffs may result in incorrect measurement results. Do not use a mobile phone or other devices that emit electromagnetic fields near the device except when in use for wireless communications. This may result in incorrect operation of the device. Do not disassemble the monitor or arm cuff. This may cause an inaccurate reading. Do not use in a location with moisture, or a location where water may splash on the device. This may damage the device. Do not use the device in a moving vehicle (car, airplane). Read "If your systolic pressure is more than 210 mmHg" (page11) of this instruction manual, if your systolic pressure is known to be more than 210 mmHg. Inflating to a higher pressure than necessary may result in bruising
Page 6
Important Safety Information
EN
Unplug monitor when not in use. Disconnect the power plug before cleaning. Use only an OMRON AC adapter designed for this device. Use of unsupported adapters may damage and/or may
be hazardous to the device.
(Battery Usage)
Do not insert the batteries with their polarities incorrectly aligned. Use only 4 “AA” alkaline or manganese batteries with this device. Do not use other types of batteries. Do not use
new and used batteries together. Remove the batteries if the device will not be used for three months or more.
General Precautions
• Do not forcibly crease the arm cuff or the air tube excessively.
• Do not press the air tube while taking a measurement.
• To unplug the air plug, pull on the air plug at the connection with the monitor, not the tube itself.
• Do not drop the monitor or subject device to strong shocks or vibrations.
• Do not inflate the arm cuff when it is not wrapped around your arm.
• Do not use the device outside the specified environment. It may cause an inaccurate reading.
Page 7
1.Know Your Device
Monitor
Air jack Blood pressure color indicator Date/Time setting button USER ID selection switch Display Memory button START/STOP button Up/Down buttons Battery compartment AC adapter jack (for optional AC adapter)
Display
Memory symbol USER ID symbol Average value symbol Systolic blood pressure Diastolic blood pressure
Transfer indicator Memory full symbol OK symbol
Heartbeat symbol
(Flashes during measurement)
Open the rear cover page to read the following:
The letter identifiers on the rear cover page correspond to those in the body of this page.
ABCDEFGHIJNOP
Q
R
STU
V
Page 8
1. Know Your Device
EN
1.1
Display Symbols
Irregular Heartbeat Symbol ( )
When the monitor detects an irregular rhythm two or more times during the measurement, the irregular heartbeat symbol will appear on the display with the measurement values.
An irregular heartbeat rhythm is defined as a rhythm that is 25% less or 25% more than the average rhythm detected while the monitor is measuring the systolic and diastolic blood pressure.
If the irregular heartbeat symbol displays with your measurement results, we recommend you consult your physician. Follow the directions of your physician.
Movement Error Symbol ( )
The movement error symbol is displayed if you move your body during the measurement. Please remove the arm cuff, and wait 2-3 minutes. Take another measurement, remain still during measurement.
Normal Heartbeat
Irregular Heartbeat
Pulse
Blood pressure
Blood pressure
Short
Long
Pulse
Page 9
1. Know Your Device
Blood Pressure Color Indicator
If your Systolic Blood Pressure is 135 mmHg or above and/or the Diastolic Blood Pressure is 85 mmHg or above, the blood pressure color indicator will light in “orange” when the measurement result is displayed. If the measurements are within the standard range, the blood pressure color indicator will light in “green”.
2013 ESH/ESC Guidelines for the management of arterial hypertension
Definitions of hypertension by office and home blood pressure levels
These are from statistical values for blood pressure
.
1.2
Before Taking a Measurement
To help ensure an accurate reading, follow these directions:
1. Avoid bathing, drinking alcohol or caffeine, smoking, exercising and eating for 30 minutes before taking a
Office Home
Systolic Blood Pressure 140 mmHg 135 mmHg
Diastolic Blood Pressure 90 mmHg 85 mmHg
Page 10
EN
2.Preparation
2.1
Battery Installation
1. Remove the battery cover.
2. Insert 4 “AA” batteries as
indicated in the battery compartment.
3. Replace the battery cover.
Notes:
• When the low battery symbol ( ) appears on the display, turn the monitor off, then replace all batteries
Page 11
2. Preparation
2.2
Setting the Date and Time
Set the monitor to the correct date and time before taking a measurement for the first time.
1. Press the Date/Time setting ( ) button twice.
The year flashes on the Date/Time display.
2. Push or button to change the year.
Push button to confirm the year and then the month flashes. Repeat the same steps to change the month, day, hour, and minute.
Open the rear cover page to read the following:
The letter identifiers on the rear cover page correspond to those in the body of this page.
C
W
Year
Month
Day
Page 12
EN
3.Using the Device
3.1
Applying the Arm Cuff
Remove tight-fitting clothing or tight rolled up sleeve from your left upper arm. Do not place the arm cuff over thick clothes.
1. Insert the air plug into the air jack securely.
2. Apply the arm cuff to your left upper arm.
The bottom edge of the arm cuff should be 1/2 inch (1 to 2 cm) above the elbow.
Air tube
is on the inside of your arm and aligned with your middle finger.
3. Secure closed with the fabric fastener.
Open both the front and rear covers to read the following:
The letter identifiers on the cover page correspond to those in the body of this page.
L
AaM
Page 13
3. Using the Device
3.2
How to Sit Correctly
To take a measurement, you need to be relaxed and comfortably seated, under comfortable room temperature. Avoid bathing, drinking alcohol or caffeine, smoking,
exercising or eating 30 minutes before taking a measurement.
• Sit on a chair with your feet flat on the floor.
• Sit upright with your back straight. ---
• Sit with your back and arm being supported.
• The arm cuff should be placed on your arm at the same level as your heart. ---
c
d
Page 14
3. Using the Device
EN
3.3
Taking a Measurement
Notes:
• To stop a measurement, press the START/STOP button once to deflate the arm cuff.
• Remain still and quiet while taking a measurement.
The monitor is designed to take measurements and store the measurement values in the memory for 2 people using USER ID 1 and USER ID 2.
1. Select your USER ID (1 or 2).
2. Press the START/STOP button.
The arm cuff starts to inflate automatically.
If your systolic pressure is
START
INFLATE
DEFLATE
COMPLETE
Page 15
3. Using the Device
3. Remove the arm cuff.
4. Press the START/STOP button to turn the monitor off.
The monitor automatically stores the measurement result in its memory. It will automatically turn off after 2 minutes.
Note: Wait 2-3 minutes before taking another measurement. Waiting between measurements allows the
arteries to return to the condition prior to taking a measurement.
Using the Guest Mode
The monitor stores measurement values for 2 users in the memory. The guest mode can be used to take a single measurement for another user. No measurement values are stored in the memory when the guest mode is selected.
1. Press and hold the START/STOP
Page 16
3. Using the Device
EN
DO NOT adjust medication based on measurement results from this blood pressure monitor. Take
medication as prescribed by your physician. Only a physician is qualified to diagnose and treat High
Blood Pressure. This monitor is not intended to be a diagnostic device. Always consult your physician. Self-diagnosis of measurement results and self-treatment are dangerous. Read "If your systolic pressure is more than 210 mmHg" (page11) of this instruction manual, if your
systolic pressure is known to be more than 210 mmHg. Inflating to a higher pressure than necessary
may result in bruising where the cuff is applied.
Page 17
3. Using the Device
3.4
Using the Memory Function
The monitor automatically stores the results up to 60 sets for each user (1 and 2). It can also calculate an average value based on the last 3 measurement values taken within 10 minutes.
Notes:
• If there are only 2 measurement values in the memory for that period, the average will be based on these 2 values.
• If there is 1 measurement value in the memory for that period, this is displayed as the average.
• If the memory is full, the monitor will delete the oldest value.
• When viewing the measurement value taken without setting the date and time, “-/ - -:--” is displayed instead of the date and time.
To View the Measurement Values Stored in Memory
1. Select your USER ID (1 or 2).
Page 18
3. Using the Device
EN
3. Press the or button to view the values stored in the
memory.
: To view the older values
: To view the more recent values
To View the Average Value
1. Select your USER ID (1 or 2).
2. Press and hold the button for more
than 3 seconds.
Notes:
• If the previous measurement was taken without setting the date and time,
Page 19
3. Using the Device
To Pair This Device With a Smartphone
To begin using the OMRON Wellness software for the first time, please visit www.omronwellness.com for the initial set-up instructions.
1. Download and install onto your smartphone, the free
"Omron Wellness" APP.
2. Open the App on your smartphone and follow set-up and
pairing instructions.
Page 20
3. Using the Device
EN
4. Open the App on your smartphone and follow the
device pairing instructions shown on your smartphone, while the transfer indicator is flashing on the display.
The OK symbol and will flash when pairing is completed. Any readings currently saved in the blood pressure monitor's memory will automatically be transfered to the Omron Wellness App after successful completion of the pairing process.
Notes:
• If pairing has failed, the screen to the right is displayed.
Page 21
3. Using the Device
To Unpair Your Device
1. Press the Date/Time setting ( ) button.
The transfer indicator ( ) will appear on the display.
2. While holding the button down,
press the START/STOP button for more than 2 seconds.
The OK symbol and will flash if your device has been unpaired.
Notes:
• Unpairing your device will not delete the information in the phone app.
• The monitor will automatically turn off after 10 seconds.
Page 22
3. Using the Device
EN
To Delete All the Values Stored in Memory
The values stored in the memory are deleted by USER ID.
1. Select your USER ID (1 or 2).
2. Press the Memory button, while the memory symbol ( )
appears.
3. While holding the button down,
press the START/STOP button for more than 3 seconds.
Page 23
4.
Error Messages and Troubleshooting
4.1
Error Messages
Display Cause Solution
Irregular heartbeats are detected.
Remove the arm cuff. Wait 2-3 minutes and then take another measurement.
Repeat the steps in section 3.3. If this error continues to appear, contact your physician.
Movement during measurement.
Carefully read and repeat the steps in section
3.3.
The batteries are low.
You should replace the batteries with new ones ahead of time.
Refer to section 2.1.
The batteries are exhausted.
You should replace the batteries with new ones at once.
Refer to section 2.1.
Page 24
4. Error Messages and Troubleshooting
EN
Air plug disconnected.
Insert the air plug securely. Refer to section 3.1.
Arm cuff is applied too loosely.
Apply the arm cuff tighter. Refer to section 3.1.
Air is leaking from the arm cuff.
Replace the arm cuff with a new one. Refer to section 5.3.
Movement during measurement and the arm cuff has not been inflated sufficiently.
Repeat measurement. Remain still and do not talk during measurement.
Refer to section 3.3.
If “E2” appears repeatedly, inflate the arm cuff manually until it is 30 to 40 mmHg above your previous measurement result.
Refer to section 3.3.
The arm cuff was inflated exceeding the maximum allowable pressure, and then deflated automatically when inflating the arm
Do not touch the arm cuff and/or bend the air tube while taking a measurement. Do not inflate the arm cuff more than necessary.
Display Cause Solution
Page 25
4. Error Messages and Troubleshooting
4.2
Troubleshooting
Problem Cause and Solution
No power. No display appears on the monitor.
Replace all batteries with new ones. Check the battery installation for proper placement of
the battery polarities. Refer to
section 2.1.
Measurement values appear too high or too low.
Blood pressure varies constantly. Many factors including stress, time of day, and how you wrap the cuff, may affect your blood pressure. Review the section 1.2 and section 3.3.
The destination device is too far away from the monitor. After checking that there are no sources of interference nearby, move the device to a distance within 16 ft. (5 m) of the monitor.
The Bluetooth function on the destination device is turned off. Turn the on the Bluetooth function and try sending the data again.
Page 26
EN
5.
Maintenance and Storage
5.1
Maintenance
To protect your device from damage, please observe the following:
• Store the device and the components in a clean, safe location.
• Do not use any abrasive or volatile cleaners.
• Do not wash the device and any components or immerse them in water.
• Do not use gasoline, thinners or similar solvents to clean the device.
• Use a soft and dry cloth, or a soft and moistened cloth and neutral soap to clean on the monitor and the arm cuff.
• Changes or modification not approved by the manufacturer will void the user warranty. Do not disassemble or attempt to repair the device or components. Consult Customer Service.
Page 27
5. Maintenance and Storage
5.2
Storage
1. Unplug the air plug from the air jack.
2. Gently fold the air tube into the
arm cuff.
Note: Do not bend or crease the air tube excessively.
Do not store the device in the following situations:
• If the device is wet.
• Locations exposed to extreme temperatures, humidity, direct sunlight, dust or corrosive vapors such as bleach.
Page 28
5. Maintenance and Storage
EN
5.3
Optional Medical Accessories
Arm Cuff
Arm circumference
9” - 17” (22 - 42 cm)
AC Adapter
ComFitTM Cuff (CFX-WR17)
(Model: HEM-FL31)
HEM-ADPTW5
Page 29
5. Maintenance and Storage
Using the Optional AC Adapter
1. Insert the AC adapter plug
into the AC adapter jack on the rear side of the monitor.
2. Plug the AC adapter into an
electrical outlet.
To disconnect the AC adapter, unplug the AC adapter from the electrical outlet first and then remove the AC adapter plug from the monitor.
Page 30
EN
6.Specifications
Model
BP761 HEM-7320T-Z
Display LCD digital display Measurement range Pressure: 0 to 299 mmHg
Pulse: 40 to 180 beats / min.
Accuracy Pressure: ±3 mmHg or 2% of reading
Pulse: ± 5% of display reading
Inflation Fuzzy-logic controlled by electric pump Deflation Automatic pressure release valve Measurement method Oscillometric method IP classification IP 20 Power source
4 “AA” batteries 1.5V or optional AC adapter (INPUT AC100-240V 50/60Hz 0.12A)
Battery life Approximately 1000 measurements (using new alkaline batteries) Operating temperature / humidity 50°F to 104°F (10°C to 40°C) / 15 to 90% RH Storage temperature / humidity / air pressure
-4°F to 140°F (-20°C to 60°C) / 10 to 95% RH / 700 to 1060 hPa
Weight Monitor : Approximately 13 5/8 oz. (385 g) not including batteries
Arm cuff : Approximately 5 3/4 oz. (163 g)
Dimensions Monitor : Approximately 4 7/8” (w) × 3 1/2” (h) × 6 3/8” (l)
(124 mm × 90 mm × 161 mm)
Arm cuff : Approximately 5 3/4” × 21” (air tube: 29 1/2”)
(145 mm × 532 mm (air tube: 750 mm))
Page 31
7.
FCC/IC Statement and Trademarks
FCC CAUTION Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Page 32
7. FCC/IC Statement and Trademarks
EN
This Product operates in the unlicensed ISM band at 2.4GHz. In case this Product is used around the other wireless devices including microwave and wireless LAN, which operate same frequency band of this Product, there is a possibility that interference occurs between this Product and such other devices. If such interference occurs, please stop the operation of other devices or relocate this Product before using this Product or do not use this Product around the other wireless devices.
The Bluetooth
®
Smart word mark and logos are registered trademarks owned by Bluetooth SIG,
Inc. and any use of such marks by OMRON HEALTHCARE Co.,Ltd. is under license. Other trademarks and trade names are those of their respective owners.
Apple, the Apple logo, iPad, and iPhone are trademarks of Apple Inc., registered in the U.S. and other countries. App Store is a service mark of Apple Inc.
Android and Google Play are both trademarks of Google Inc.
Samsung and Galaxy S are both registered trademarks of Samsung Electronics Co., Ltd.
Page 33
8.Limited Warranty
Your BP761 Automatic Blood Pressure Monitor, excluding the arm cuff and battery, is warranted to be free from defects in materials and workmanship appearing within 5 years from the date of purchase, when used in accordance with the instructions provided with the monitor. The arm cuff is warranted to be free from defects in materials and workmanship appearing within 1 year from the date of purchase when the monitor is used in accordance with the instructions provided with the monitor. The above warranty extends only to the original retail purchaser. We will, at our option, replace without charge any monitor or arm cuff covered by the above warranty. Replacement is our only responsibility and your only remedy under the above warranty.
To obtain warranty service contact Customer Service by calling 1-800-634-4350 for the address of the inspection
center and the return shipping and handling fee.
Enclose the original printed receipt. Include a letter, with your name, address, phone number, and description of the specific problem. Pack the product carefully to prevent damage in transit. Because of possible loss in transit, we recommend insuring the product with return receipt requested.
THE FOREGOING IS THE SOLE WARRANTY PROVIDED BY OMRON IN CONNECTION WITH THIS PRODUCT, AND OMRON HEREBY DISCLAIMS ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IMPLIED WARRANTIES AND OTHER TERMS THAT MAY BE IMPOSED BY LAW, IF ANY, ARE LIMITED IN DURATION TO THE PERIOD OF THE ABOVE EXPRESS WARRANTY.
Page 34
EN
9.
Guidance and Manufacturer’s Declaration
OMRON Automatic Blood Pressure Monitor Information for accompanying documents in the scope of IEC60601-1-2:2007 Model: BP761 including AC-adapter
Important information regarding Electro Magnetic Compatibility (EMC)
With the increased number of electronic devices such as PC’s and mobile (cellular) telephones, medical devices in use may be susceptible to electromagnetic interference from other devices. Electromagnetic interference may result in incorrect operation of the medical device and create a potentially unsafe situation. Medical devices should also not interfere with other devices.
In order to regulate the requirements for EMC (Electro Magnetic Compatibility) with the aim to prevent unsafe product situations, the IEC60601­1-2 standard has been implemented. This standard defines the levels of immunity to electromagnetic interferences as well as maximum levels of electromagnetic emissions for medical devices.
Medical devices manufactured by OMRON Healthcare conform to this IEC60601-1-2:2007 standard for both immunity and emissions. Nevertheless, special precautions need to be observed:
• The use of accessories and cables other than those specified by OMRON, with the exception of cables sold by OMRON as replacement parts for internal components, may result in increased emission or decreased immunity of the device.
• The medical devices should not be used adjacent to or stacked with other equipment. In case adjacent or stacked use is necessary, the medical device should be observed to verify normal operation in the configuration in which it will be used.
• Refer to further guidance below regarding the EMC environment in which the device should be used.
• The MEDICAL ELECTRICAL EQUIPMENT BP761 including AC-adapter needs special precautions regarding EMC and needs to be installed and put into service according to the EMC information provided in this documentations.
• The Essential Performance of the BP761 including AC-adapter is to measure a blood pressure and a pulse rate and using the memory function.
The BP761 including AC-adapter may be interfered with by other equipment, even if that other equipment complies with CISPR EMISSION requirements.
Page 35
9. Guidance and Manufacturer’s Declaration
Guidance and manufacturer’s declaration - electromagnetic immunity
OMRON BP761 including AC-adapter is intended for use in the electromagnetic environment specified below. The customer or the user of this OMRON BP761 including AC-adapter should assure that it is used in such environment.
Immunity test IEC 60601 test level Compliance level Electromagnetic environment - guidance
Electrostatic discharge (ESD) IEC 61000-4-2
±6 kV contact ±8 kV air
±6 kV contact ±8 kV air
Floor should be wood, concrete, or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30 %.
Electrical fast transient/burst IEC 61000-4-4
±2 kV for power supply lines ±1 kV for input/output lines
±2 kV for power supply lines ±1 kV for input/output lines
Mains power quality should be that of a typical commercial and/or hospital environment.
Surge IEC 61000-4-5
±1 kV line(s) to line(s) ±2 kV line(s) to earth
±1 kV line(s) to line(s) ±2 kV line(s) to earth
Mains power quality should be that of a typical commercial and/or hospital environment.
Voltage dips, short interruptions and voltage variations on power supply inputlines IEC 61000-4-11
<5 % UT (>95 % dip in UT)
for 0.5 cycle
<5 % UT (>95 % dip in UT)
for 0.5 cycle
Mains power quality should be that of a typical commercial and/or hospital environment. If the user of the OMRON BP761 including AC­adapter requires continued operation during power mains interruption, it is recommended that the OMRON BP761 including AC-adapter be powered from an uninterruptible power supply.
40 % UT (60 % dip in UT)
for 5 cycles
40 % UT (60 % dip in UT)
for 5 cycles
70 % UT (30 % dip in UT)
for 25 cycles
70 % UT (30 % dip in UT)
for 25 cycles
<5 % UT (95 % dip in UT)
for 5 sec.
<5 % UT (95 % dip in UT)
for 5 sec.
Power frequency (50/60 Hz)
Power frequency magnetic fields should be at
Page 36
9. Guidance and Manufacturer’s Declaration
EN
Guidance and manufacturer’s declaration - electromagnetic immunity
OMRON BP761 including AC-adapter is intended for use in the electromagnetic environment specified below. The customer or the user of this OMRON BP761 including AC-adapter should assure that it is used in such environment.
Immunity test IEC 60601 test level
Compliance
level
Electromagnetic environment - guidance
Conducted RF IEC 61000-4-6
Radiated RF IEC 61000-4-3
3 V rms 150 kHz to 80 MHz
3 V/m 80 MHz to 2.5 GHz
3 V rms
3 V/m
Portable and mobile RF communications equipment should be used no closer to any part of the OMRON BP761 including AC-adapter including cables, than the recommended separation distance calculated from the equation appropriate to the frequency of the transmitter.
Recommend separation distance
d = 1.2
d = 1.2
80 MHz to 800 MHz
d = 2.3
800 MHz to 2.5 GHz
where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in meters (m). Field strengths from fixed RF transmitters as determined by an electromagnetic
site survey,
a
should be less than the compliance level in each frequency range.
b
Interference may occur in the vicinity of equipment marked with the following
P
P
P
Page 37
9. Guidance and Manufacturer’s Declaration
Recommended separation distance between portable and mobile RF communications equipment
and the OMRON BP761 including AC-adapter
OMRON BP761 including AC-adapter is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of this OMRON BP761 including AC-adapter can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the OMRON BP761 including AC-adapter as recommended below, according to the maximum output power of the communications equipment.
Output Power of Transmitter in Watt
Separation distance according to frequency of transmitter in meter
150 kHz to 80 MHz
d = 1.2
80 MHz to 800 MHz
d = 1.2
800 MHz to 2.5GHz
d = 2.3
0.01 0.12 0.12 0.23
0.1 0.38 0.38 0.73
1 1.2 1.2 2.3
10 3.8 3.8 7.3
100 12 12 23
For transmitters rated at a maximum output power not listed above, the recommended separation distance d in meters (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W)
according to the transmitter manufacturer. Note: At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies. Note: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures,
objects, and people.
PPP
Page 38
N
Q
P
O
W
E
K
L
H
G
A
GI
HJ
C
D
B
F
X
Page 39
1 2
b
c
d
b
a
A
L
Page 40
Manufactured for/Fabricado para :
Loading...