Before Using the Monitor
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Operating the Device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Risk of Electrical Shock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Care and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Before Taking a Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Operating Instructions
Know Your Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Unit Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Display Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Irregular Heartbeat Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Movement Error Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Morning Hypertension Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Heartbeat Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Average Value Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Morning Average Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Evening Average Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Cuff Wrap Guide Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Using the AC Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Battery Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Setting the Date and Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Applying the Arm Cuff . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23

TABLE OF CO NT ENT S

Taking a Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
Cuff Wrap Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
Special Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
Using the Memory Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
Averaging Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
To Display the Measurement Values . . . . . . . . . . . . . . . . . . . . . . .32
Morning and Evening Averages . . . . . . . . . . . . . . . . . . . . . . . . . .33
Morning Averages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
Evening Averages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
To D ispla y Morn in g an d Ev en in g Aver ag es . . . . . . . . . . . . . . . . . 34
Display Combinations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35
To D elete A ll Val ue s St or ed i n th e Me mo ry . . . . . . . . . . . . . . . . .3 6
Care and Maintenance
Care and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37
Error Indicators and Troubleshooting Tips . . . . . . . . . . . . . . . . . . . . . . . .39
FCC Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41
Limited Warranties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43
TABLE OF CO NT ENT S
3
4
Thank you for purchasing the Omron®BP760 IntelliSense®Automatic Blood Pressure Monitor with ComFit
TM
Cuff.

INTRODUCTION

Fill in for future reference.
DATE PURCHASED: __________________
SERIAL NUMBER: ____________________
Yo u r n e w d i g i ta l b lo o d p re s s u re m o ni t o r us e s th e o s ci l l om e t r ic m e t ho d of blood pressure measurement. This means the monitor detects your blood’s movement through your brachial artery and converts the movements into a digital reading. An oscillometric monitor does not need a stethoscope so the monitor is simple to use.
The BP760 comes with the following components:
• Monitor • ComFitTMCuff • AC Adapter
• Storage Case
• Instruction Manual printed in English and Spanish
• Quick Start Guide
The BP760 IntelliSense®Automatic Blood Pressure Monitor is intended for home use.
SAVE THESE INSTRUCTIONS
Before Using the Monitor
• Staple your purchase receipt here
• Register your product on-line at www.register-omron.com
5
To a ssu re t h e cor re ct us e o f t he p ro duc t b as ic sa fe t y mea su re s s ho uld always be followed including the warnings and cautions listed in this instruction manual.
WAR NIN G
Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
SAFETY SYMBOLS USED IN THIS INSTRUCTION MANUAL
CAUTION
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury to the user or patient or damage to the equipment or other property.
OPERATING THE DEVICE
Contact your physician for specific information about your blood pressure. Self-diagnosis and treatment using measured results may be dangerous. Follow the instructions of your physician or licensed healthcare provider.
DO NOT adjust medication based on measurement results from this blood pressure monitor. Take medication as prescribed by your physician. Only a physician is qualified to diagnose and treat High Blood Pressure.
The monitor is not intended to be a diagnostic device.
If battery fluid should get in your eyes, immediately rinse with plenty of clean water. Contact a physician immediately.
Read all of the information in the instruction manual and any other literature in the box before operating the unit.

SAFETY INFORMATION

OPERATING THE DEVICE (continued)
This device is intended for use in measuring blood pressure and pulse rate in the adult population. Do not use this device on infants or persons who cannot express their intentions.
Read the Special Conditions section (page 30) of the instruction manual if your systolic pressure is known to be more than 220 mmHg. Inflating to a higher pressure than necessary may result in bruising where the cuff is applied.
Operate the device only as intended. Do not use the device for any other purpose.
Dispose of the device, components and optional accessories according to applicable local regulations. Unlawful disposal may cause environmental pollution.
Do not use a cellular phone near the device. It may result in an operational failure.
Use only Omron authorized parts and accessories. Parts and accessories not approved for use with the device may damage the unit.
Use only 1.5V alkaline batteries with this device. Do not use other types of batteries. This may damage the unit.
SAFETY INFORMATION
6
RISK OF ELECTRICAL SHOCK
Do not plug or unplug the power cord into the electrical outlet with wet hands.
Do not overload power outlets. Plug the device into the appropriate voltage outlet.
CARE AND MAINTENANCE
Do not subject the monitor to strong shocks, such as dropping the unit on the floor.
Do not submerge the device or any of the components in water.
Store the device and the components in a clean, safe location.
Changes or modification not approved by Omron Healthcare will void the user warranty. Do not disassemble or attempt to repair the unit or components.
SAFETY INFORMATION
7
8

BEFORE TAKING A MEASUREMENT

To e ns ur e a re li ab le r ea di ng f ol low th ese re co mm enda tion s:
1. Avoid eating, drinking alcohol, smoking, exercising, and bathing for 30 minutes prior to taking a measurement. Rest for at least 15 minutes prior to taking the measurement.
2. Stress raises blood pressure. Avoid taking measurements during stressful times.
3. Measurements should be taken in a quiet place.
4. Remove tight-fitting clothing from your arm.
5. Sit on a chair with your feet flat on the floor. Rest your arm on a table so that the cuff is at the same level as your heart.
6. Remain still and do not talk during the measurement.
7. Wait 2-3 minutes between measurements. The wait time allows the arteries to return to the condition prior to taking the blood pressure measurement. You may need to increase the wait time depending on your individual physiological characteristics.
8. Keep a record of your blood pressure and pulse readings for your physician. A single measurement may not provide an accurate indication of your true blood pressure. You need to take and record several readings over a period of time. Try to measure your blood pressure at about the same time each day for consistency.
9

KNOW YOUR UNIT

Main Unit:
Air Jack
Battery Compartment
Start/Stop Button
Morning/Evening Average () Button
Memory ( ) Button
Display
AC Adapter Jack
Operating Instructions
Up/Down (
/
) Buttons
SET Button
KNOW YOUR UNIT
10
Components:
Arm Cuff
Air Tube
Air Plug (Connects to Air Jack)
AC Adapter
Storage Case
Housing
Cord
7 series
Blood Pressure Monitor
with ComFitTMCuff
ModelBP760
INSTRUCTION MANUAL
ESPAÑOL
ENGLISH
Quick Start Guide
Instruction Manual
11

UNIT DISPLAY

Diastolic Blood Pressure
Systolic Blood Pressure
Movement Symbol
Pulse Display / Memory Number
Date/Time Display
Low Batt ery Indicator
Deflation Symbol
Morning Average Symbol
Heartbeat Symbol
Irregular Heartbeat Symbol
Evening Average Symbol
Avera ge Val ue Sy mbol
Memory Symbol
Morning Hypertension Symbol
Week Disp lay
Blood Pressure Level Indicator
Cuff Wrap Guide
12
IRREGULAR HEARTBEAT SYMBOL ( )
When the monitor detects an irregular rhythm two or more times during the measurement, the Irregular Heartbeat Symbol ( ) will appear on the display with the measurement values.
An irregular heartbeat rhythm is defined as a rhythm that varies by less than 25% from the average rhythm or 25% more than the average rhythm detected while the monitor is measuring the systolic and diastolic blood pressure.
If the irregular heartbeat symbol ( ) displays with your measurement results, we recommend you consult your physician. Follow the directions of your doctor.
MOVEMENT ERROR SYMBOL ( )
The Movement Error Symbol is displayed if you move your body during the measurement. Please remove the arm cuff, and wait 2-3 minutes. Take a no th er m ea su re ment , re ma in s ti ll d ur in g in fl atio n.
Normal Heartbeat
Irregular Heartbeat
Pulse
Blood
pressure
Pulse
Blood
pressure
Short Long
DISPLAY SYMBOLS
The American Heart Association1recommends the following guideline for upper limit of normal for home blood pressure readings:
AHA Home Guideline for Upper Limit of Normal BP
Systolic Blood Pressure 135 mmHg
Diastolic Blood Pressure 85 mmHg
This is a general guideline because blood pressure depends on age and morbidity. The AHA recommends a lower home blood pressure goal for certain patients, including diabetic patients, pregnant women, and patients with renal failure
1
.
The monitor is not intended to be a diagnostic device.
MORNING HYPERTENSION SYMBOL ( )
The Morning Hypertension Symbol is displayed if the morning average reading for a week is above 135 for the Systolic Blood Pressure value and/or 85 for the Diastolic Blood Pressure value when viewing the Morning Averages and the Evening Averages in the memory.
Omron Healthcare recommends you contact your physician if the MORNING HYPERTENSION SYMBOL and/or the HEARTBEAT SYMBOL appear on the display with your measurement values.
DISPLAY SYMBOLS
13
1
American Heart Association Scientific Statement 2004
HEARTBEAT SYMBOL ( )
TA KI NG A M E AS UR EM E NT
The Heartbeat Symbol flashes on the display during the measurement. The Heartbeat Symbol flashes at every heartbeat.
AV E R A G E V A L U E S Y M B O L ( )
The Average Value Symbol is displayed when you press the memory button. The most recent average reading appears on the display screen.
MORNING AVERAGE SYMBOL ( )
The Morning Average symbol is displayed when viewing Morning Ave ra ges using the Memory F unction.
EVENING AVERAGE SYMBOL ( )
The Evening Average symbol is displayed when viewing Evening Ave ra ges using the Memory F unction.
CUFF WRAP GUIDE SYMBOL( / )
When the cuff is applied correctly, ( ) is displayed while taking a measurement or using the memory function. If the cuff is not applied correctly, ( ) is displayed.
DISPLAY SYMBOLS