A3C
8
Approved Standard Ratings
UL (File No. E41515), CSA (File No. LR45258)
Standard Load: 0.5 A at 250 VAC
1 A at 125 VAC
1 A at 30 VDC
Microload: 0.1 A at 125 VAC
0.1 A at 30 VDC
Note: Certification has been obtained for the Switch Unit.
For detailed information on individual products that have received
certification, consult your supplier.
CCC (GB14048.5)
Standard Load: 0.5 A at 250 VAC
Microload: 0.1 A at 250 VAC
Ratings
Note: The above ratings are for testing under the following conditions:
1) Load: Resistive load
2) Mounting conditions: No vibrations or shock
3) Temperature: 20°C ± 2°C
4) Operation frequency: 20 operations/minute
* The minimum permissible load is 1 mA, 5 VDC.
LED Lamp
Incandescent Lamp
Characteristics
*1. With alternate-operation models, one operation cycle consists of set and
reset operations.
*2. The figure given above for the dielectric strength between lamp terminals is
for when there is no LED lamp or incandescent lamp mounted.
*3. No malfunction for more than 1s.
Operating Characteristics
* Alternate operation models only.
Contact Form
Model Item AC resistive load DC resistive load
Standard load
0.5 A at 250 VAC
1 A at 125 VAC
1 A at 30 VDC
Microload * 0.1 A at 125 VAC 0.1 A at 30 VDC
Rated voltage Rated current
Operating
voltage
Internal limiting
resistance
5 VDC 30 mA 5 VDC ± 5% 33 Ω
12 VDC 15 mA 12 VDC ± 5% 270 Ω
24 VDC 10 mA 24 VDC ± 5% 1,600 Ω
Rated voltage Rated current Operating voltage
6 VAC/DC 60 mA 5 VAC/DC
14 VAC/DC 40 mA 12 VAC/DC
28 VAC/DC 24 mA 24 VAC/DC
Operating frequency
Mechanical
Momentary-action models: 120 operations/minute max.
Alternate-action models: 60 operations/minute max. *1
Electrical 20 operations/minute max.
Contact
Resistance
Standard load 50mΩ max.
Microload 100mΩ max.
Insulation resistance 100 MΩ min. (at 500 VDC)
Dielectric
strength
Between terminals
of same polarity
1,000 VAC, 50/60 Hz for 1 min
Between terminals
of different polarity
2,000 VAC, 50/60 Hz for 1 min
Between each
terminal and ground
2,000 VAC, 50/60 Hz for 1 min
Between lamp
terminals
1,000 VAC, 50/60 Hz for 1 min *2
Vibration
resistance
Malfunction 10 to 55 Hz, 1.5-mm double amplitude *3
Shock
resistance
Destruction 500 m/s
2
Malfunction 150 m/s2 *3
Durability
Mechanical
Momentary-operation models: 1,000,000 operations min.
Alternate-operation models: 100,000 operations min. *1
Electrical 100,000 operations min.
Weight
Approx. 5 g <The weight indicated here applies
to the lighted models (SPST-NO+SPST-NC).>
Ambient operating temperature−10°C to +55
°C
(with no icing or condensation)
Ambient operating humidity
35% to 85%RH
Ambient storage temperature−25°C to +65°C (with no icing or condensation)
Degree of protection IP40
Electric shock protection class
Class II
PTI (proof tracking index) 175
Pollution degree 3 (IEC60947-5-1)
Operating force OF max. 2.45 N {250 gf}
Releasing force RF min. 0.29 N {30 gf}
Total travel TT Approx. 3.5 mm
Lock travel alternate LTA min. * 0.5 mm
Pretravel PT max. 2.5 mm
Contact name Contact form
SPDT