OMRON A22NZ-S-P1AN Datasheet

Page 1
New Product
A22E Common NoteA22NE-P
Common Accessories and Tools
For the most recent information on models that have been certified for safety standards, refer to your OMRON website.
Be sure to read the "Safety Precautions" on pages 15, 28, and 37.
Emergency Stop Pushbutton Switches (22-dia. or 25-dia.)
A22E/A22NE-P
Install in 22-dia. or 25-dia. Panel Cutout (When Using a Ring)
• Direct opening mechanism to open the circuit when the contact welds.
• Safety lock mechanism prevents operating errors.
• Lever for easily mounting and removing the Switch Blocks.
• Finger protection mechanism on Switch Unit provided as a standard feature.
• Use 25-dia. ring to install in 25-dia. panel cutouts.
Types of Emergency Stop Pushbutton Switches
A22E Screw Terminal Block Types ...................................from page 2
A22NE-P Push-in Plus Terminal Block Types........................ from page 16
Common Items
Common Accessories / Tools................................................... from page 32
Safety Precautions.....................................................................from page 37
1
Page 2
A22E A22NE-P
Common Note
Common Accessories and Tools
Emergency Stop Pushbutton Switches (22-dia. or 25-dia.) Screw Terminal Block types
For the most recent information on models that have been certified for safety standards, refer to your OMRON website.
1. Lighted/Non-lighted 4. Contacts
5. Configuration
3. LED Lamp voltage
Lighting unit (Direct lighting)
Lighting unit (Voltage-reduction lighting)
2. Operation Unit size (diameter)/Reset function
Code Description
None Non-lighted
L Lighted *
Code
None
B
Configuration
Switch only
Note 1. NO: 1a-contact NC: 1b-contact
2. For details on the unit position, refer to the figure below.
Switch with Integrated Control Box
Code Size Description
MP 40
dia. Pull-reset
S 30
dia.
Turn-reset
M40 dia.
L60 dia.
Code Description Operating Voltage
Lighted
(LED) *
None Non-lighted
---
6 A
12 A
12 VAC/DC
6 VAC/DC
24 A 24 VAC/DC
* Equipped with 24-VAC/DC LED.
Code Operating Voltage
T2 200 VAC
T1 100 VAC
* Lighted Emergency
Stop Switches are available only for the medium (M). turn-reset models.
6. Configuration
Code
Configuration
Neither “EMO” nor “EMS” printed, arrows engraved in red.
“EMO” printed in white, arrows engraved in red.
“EMO” and arrows printed in white.
None
EMO-RD
EMO
“EMS” and arrows printed in white.
EMS
EMS-RD
“EMS” printed in white, arrows engraved in red.
Lighted
(LED) *
Description
(Example: A22EL-M-24A-01)
Number of
Switch Blocks
Unit position
Non-lightedCode Lighted
NO NC 1 2 3 1 2 3
0 1 --- ---
NC --- Lighting unit NC
11
NC NO Lighting unit NC
02
NC --- NC NC Lighting unit NC
01
11
02
12
NCNO NC
03
NC NC NC
12
03
---
NO ---
A22E
Install in 22-dia. or 25-dia. Panel Cutout
(When Using a Ring)
• Increase wiring efficiency with three-row mounting of Switch (with non-lighted Switch Blocks, three Units can be
Units. mounted for multiple contacts).
• Mounted using either open-type (fork-type) or closed-type
(round-type) crimp terminals.
• Oil-resistant to IP65 (non-lighted models) / IP65 (lighted models).
• A lock plate is provided as a standard feature to ensure that the
control box and switch are not easily separated.
Be sure to read the "Safety Precautions" on pages 15 and 37.
Model Number Structure
Model Number Legend (Completely Assembled)........Shipped as a set which includes the Operation Unit, LED
Lamp (lighted model only), Mounting Latches, Switch Block, and Lock Plate
2
Page 3
A22E A22NE-P
Common Note
Common Accessories and Tools
Ordering Information
40-dia. head Medium Pull-reset A22E-MP
30-dia. head Small Turn-reset A22E-S
40-dia. head Medium Turn-reset A22E-M
60-dia. Large Turn-reset A22E-L
40-dia. head Medium Turn-reset With EMO Indication
40-dia. head Medium Turn-reset With EMS Indication
List of Models (Completely Assembled)
Non-lighted Models (Without EMO/EMS Indication)
* Models with Korean S-mark certification
Note: Yellow cap models are also available (not for emergency stop use). Contact your OMRON representative.
Appearance
Operation
Contact configuration
(Number of switch blocks)
1NC (1) A22E-MP-01
1NC, 1NO (2) A22E-MP-11
2NC (2) A22E-MP-02 1NC (1) A22E-S-01 *
1NC, 1NO (2) A22E-S-11 *
2NC (2) A22E-S-02 *
2NC, 1NO (3) A22E-S-12 *
3NC (3) A22E-S-03 * 1NC (1) A22E-M-01 *
1NC, 1NO (2) A22E-M-11 *
2NC (2) A22E-M-02 *
2NC, 1NO (3) A22E-M-12 *
3NC (3) A22E-M-03 * 1NC (1) A22E-L-01 *
1NC, 1NO (2) A22E-L-11 *
2NC (2) A22E-L-02 *
A22E
Set Model Color of cap
Red
Non-lighted Models (With EMO/EMS Indication)
Operation
Appearance
* Models with Korean S-mark certification
Note: The colors of switch blocks are as follows:
NO (a-contact): Black NC (b-contact): Red The above illustration shows the 2NC (2b-contact) configuration.
Contact configuration
(Number of switch blocks)
1NC (1)
1NC, 1NO (2)
2NC (2)
2NC, 1NO (3)
3NC (3)
1NC (1)
1NC, 1NO (2)
2NC (2)
2NC, 1NO (3)
3NC (3)
Set Model Color of cap
A22E-M-01-EMO *
A22E-M-01-EMO-RD A22E-M-11-EMO *
A22E-M-11-EMO-RD A22E-M-02-EMO *
A22E-M-02-EMO-RD A22E-M-12-EMO *
A22E-M-12-EMO-RD A22E-M-03-EMO *
A22E-M-03-EMO-RD A22E-M-01-EMS *
A22E-M-01-EMS-RD A22E-M-11-EMS *
A22E-M-11-EMS-RD A22E-M-02-EMS *
A22E-M-02-EMS-RD A22E-M-12-EMS *
A22E-M-12-EMS-RD A22E-M-03-EMS *
A22E-M-03-EMS-RD
Red
3
Page 4
A22E
A22E A22NE-P
Common Note
Common Accessories and Tools
Lighted Models
Appearance
40-dia. head Push-lock Turn-reset Lighting unit (Direct lighting) A22E
40-dia. head Push-lock Turn-reset Lighting unit (Voltage­reduction lighting) A22E
* Models with Korean S-mark certification
Operation Push-lock turn-reset system
Contacts
(Number of
switch blocks)
1NC (1)
1NC, 1NO (2)
2NC (2)
1NC (1)
1NC, 1NO (2)
2NC (2)
LED Lamp voltage
6 VAC/VDC A22EL-M-6A-01 * 12 VAC/VDC A22EL-M-12A-01 * 24 VAC/VDC A22EL-M-24A-01 *
6 VAC/VDC A22EL-M-6A-11 * 12 VAC/VDC A22EL-M-12A-11 * 24 VAC/VDC A22EL-M-24A-11 *
6 VAC/VDC A22EL-M-6A-02 * 12 VAC/VDC A22EL-M-12A-02 * 24 VAC/VDC A22EL-M-24A-02 *
100 VAC A22EL-M-T1-01 200 VAC A22EL-M-T2-01 100 VAC A22EL-M-T1-11 200 VAC A22EL-M-T2-11 100 VAC A22EL-M-T1-02 200 VAC A22EL-M-T2-02
Set Model
Color of cap
Red
Switch with Integrated Control Box
Appearance Contact configuration (Number of switch blocks) Model
1NC (1) A22E-M-01B *
1NC, 1NO (2) A22E-M-11B *
2NC (2) A22E-M-02B *
Note: The A22Z-B101Y Control Box is used. * Models with Korean S-mark certification
4
Page 5
A22E
A22E A22NE-P
Common Note
Common Accessories and Tools
Operation Unit
Mounting Latches
Non-lighted
Switch Blocks *
Lock Plate
Operation Unit
Lighted
LED Lamp
LED
Lock Plate
Switch Blocks + Lighting unit
Screw Terminal BlockScrew Terminal Block
Subassembled.... The Operation Unit, LED Lamp, Mounting Latches, and Switch Blocks can be ordered separately. Use them in
combination for models that are not available as assembled Units. These can also be used as inventory for maintenance parts.
* Up to three Switch Blocks can be mounted for multiple contacts.
5
Page 6
A22E
A22E A22NE-P
Common Note
Common Accessories and Tools
Operation Unit Non-lighted
Sealing capability IP65 oil-resistant models
Function Size Small (30 dia.) Medium (40 dia.) Large (60 dia.)
A22E-MP
Pull-reset ---
A22E-S
Turn-reset
Lighted
Sealing capability IP65
Function Size Medium (40 dia.)
A22EL-M
A22E-M
A22E-M-EMO A22E-M-EMO-RD
A22E-M-EMS A22E-M-EMS-RD
---
A22E-L
Turn-reset
LED lamp
Appearance LED light Rated voltage Model
6 VAC/VDC A22-6AR
Red Standard
Note: For a model with a Lighting unit (Voltage-reduction lighting), use the A22-24AR.
12 VAC/VDC A22-12AR
24 VAC/VDC A22-24AR
6
Page 7
A22E A22NE-P
Common Note
Common Accessories and Tools
Switch Non-lighted / Direct lighting
A22E
Contact specifications/ Configuration (Number of switch blocks)
For Standard loads
Voltage-reduction lighting (100 VAC, 200 VAC)
Contact specifications/ Configuration (Number of switch blocks)
For Standard loads
Note: For a model with a Lighting unit (Voltage-reduction lighting), use the A22-24AR.
Classification
Appearance
1NC (1) A22-01M A22L-01M
1NC, 1NO (2) A22-11M A22L-11M
2NC (2) A22-02M A22L-02M
Classification
Appearance
1NC (1) A22L-01M-T1 A22L-01M-T2
1NC, 1NO (2) A22L-11M-T1 A22L-11M-T2
2NC (2) A22L-02M-T1 A22L-02M-T2
Non-lighted Direct lighting
Model Model
100 VAC, Lighted 200 VAC, Lighted
Model Model
7
Page 8
A22E
A22E A22NE-P
Common Note
Common Accessories and Tools
Accessories (Order Separately)
Item Appearance Contact specifications Model Remarks
1NO (Black)
Switch Blocks (one contact)
1NC (Red)
Switch Blocks (two contacts)
Lighting unit
Mounting Latches --- A22-3200
2NO (Black)
2NC (Red)
1NC + 1NO Contact (Black/ Red)
Direct lighting A22-TN
Voltage-reduction lighting
Standard load
Microload
Standard load
Microload
Standard load
Microload
Standard load
Microload
Standard load
Microload
100 VAC A22-T1
200 VAC A22-T2
A22-10
A22-10S
A22-01
A22-01S
A22-20
A22-20S
A22-02
A22-02S
A22-11
A22-11S
Provided as standard. Order Switch Blocks only when adding or replacing them.
Order Switch Blocks only when adding or replacing them.
Used when changing the lighting method.
Provided as standard. Order Mounting Latches only when mounting Switch Blocks or Lighting Units that are purchased individually.
Lock Plate
Control Boxes (Enclosures)
Note: For details on the accessories common to the screw terminal block types and push-in plus terminal block types, refer to "Common
Accessories and Tools (Order Separately)" on page 32.
One hole, yellow box
--- A22Z-3380 Use to fix the lever on the Switch.
A22Z-B101Y
A22Z-B201Y
Material: Polycarbonate resin. The A22Z-B101Y does not support 2NO, 2NC, or 1NC + 1NO two­contacts Switch Blocks.
8
Page 9
A22E A22NE-P
Common Note
Common Accessories and Tools
Specifications
A22E
Certified Standard Ratings
• UL, cUL (File No. E41515) 6 A at 220 VAC, 10 A at 110 VAC
• TÜV (EN60947-5-1) (Low Voltage Directive) 3 A at 220 VAC
• CCC (GB14048.5) 3 A at 240 VAC, 1.5 A at 24 VDC
Ratings
Contacts (Standard Load)
Rated carry
current (A)
10
Rated
voltage
24 VAC 10 10 110 VAC 5 10 220 VAC 3 6 380 VAC 2 3 440 VAC 1 2 24 VDC 110 VDC 0.5 220 VDC 0.2 380 VDC 0.1
(V)
AC15
(Inductive
load)
--- ---
Note: 1. Rated current values are determined according to the
testing conditions. The above ratings were obtained by conducting tests under the following conditions. (1) Ambient temperature: 20°±2°C
(2) Ambient humidity: 65±5% (3) Operating frequency: 20 operations/minute
2. Minimum applicable load: 10 mA at 5 VDC
Characteristics
Item Non-lighted model Lighted model Non-lighted model
Allowable operating frequency
Insulation resistance 100 MΩ min. (at 500 VDC) Contact resistance 100 mΩ max. (initial value)
Dielectric strength
Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude (contact separation within 1 ms)
Shock resistance
Durability
Ambient operating temperature *1 -20 to +70°C -20 to +55°C -20 to +70°C Ambient operating humidity 35 to 85% RH Ambient storage temperature -40 to +70°C Degree of protection IP65 (oil-resistant) *2 *3 IP65 *2 IP65 (oil-resistant) *2 *3 Electric shock protection class Class II PTI (tracking characteristic) 175 Degree of contamination 3 (EN60947-5-1) Minimum direct opening stroke 11 mm Minimum direct opening force 45 N Conditional short-circuit current 100 A (EN 60947-5-1) Weight (for a 40-dia. head 1NC/1NO Operation Unit) Approx. 65 g Approx. 80 g Approx. 100 g
*1. With no icing or condensation. *2. The degree of protection from the front of the panel. *3. The degree of protection is IP65 even with an integrated control box, but the system is not oil resistant.
Mechanical 30 operations/minute (One operation consists of set and reset operations.) Electrical 30 operations/minute (One operation consists of set and reset operations.)
Between terminals of same polarity 2,500 VAC, 50/60 Hz for 1 min. Between each terminal and ground 2,500 VAC, 50/60 Hz for 1 min.
Destruction 1000 m/s Malfunction 250 m/s2 max. (contact separation within 1 ms) Mechanical 300,000 operations min. (One operation consists of set and reset operations.) Electrical 300,000 operations min. (One operation consists of set and reset operations.)
Rated current (A)
AC12
(Resistive
load)
Certified Standards
Certification
body
UL *1
TÜV SÜD
CQC (CCC) GB14048.5 2003010303070635
KOSHA *2 EN60947-5-1
Note:
Only models with NC contacts have a direct opening mechanism.
*1. UL-certification for CSA C22.2 No. 14 has been obtained.
Certification has been obtained for individual Switch Blocks and Lighting Units.
*2. Some models have been certified.
LED Lamp
Rated voltage Operating voltage Current value
DC13
(Inductive
load)
--- ---
1.5 10
DC12
(Resistive
load)
2
0.6
0.2
Type Turn-reset Pull-reset
2
6 VAC/VDC 6 VAC/VDC ± 5%
24 VAC/VDC 24 VAC/VDC ± 5%
Voltage-reduction lighting
Rated voltage Operating voltage Rated current
110 VAC
220 VAC
Standards File No.
UL508, C22.2 No.14
EN60947-5-1
(Certified direct opening),
EN60947-5-5
100 VAC
(95 to 115 V)
200 VAC
(190 to 230 V)
Consult your OMRON representative for details.
Consult your OMRON representative for details.
Approx. 8 mA
E41515
Approx. 8 mA12 VAC/VDC 12 VAC/VDC ± 5%
Applicable lamp (BA9S/Base: 13)
LED lamp
A22-24A@
9
Page 10
A22E
A22E A22NE-P
Common Note
Common Accessories and Tools
1
2
1
2
NC NC
1
2
X2
X1
X
(-)
(+)
3
4
1
2
1
2
X2
X1
X
(-)
(+)
X1
X2
1
2
X
3
4
X1
X2
X
1
2
1
2
AB
Type
Terminal Connection (BOTTOM VIEW)
2NC (two contacts) 2NO (two contacts)
1NC, 1NO (two contacts)
A
B
21
22
24
23
24
23
1211141312
11
Operating Characteristics
Item Turn-reset Pull-reset Total travel force (TTF) 44.1 N max. 58.8 N max. Return force (RF) 0.25 N·m * max. 58.8 N max. Total travel (TT) 10 ±1 mm 5.5 ±1 mm
* Rotation torque value.
Terminal Arrangement (BOTTOM VIEW)
Non-lighted (two contacts) Non-lighted (three contacts) Lighted (two contacts)
20.7
10
OPEN
LOC
10
Switch Blocks
16.7
M3.5 screws
Switch Blocks
Switch Blocks
Terminal connection
Type
Non-lighted
Lighted with Direct lighting
1NC, 1NO (two contacts) 2NC (two contacts) 2NC, 1NO (three contacts) 3NC (three contacts)
NC NO
1
2
3
4
Lighted with Voltage-reduction lighting
16.7
Lighting unit
Terminal Connection (BOTTOM VIEW)
NC NONC
22
121
NC NCNC
3
4
2
12121
2
Note: The above terminal connection diagrams are examples of the number of contacts.
Terminal wiring drawings of two-contact Switch Units
10
Page 11
A22E A22NE-P
Common Note
Common Accessories and Tools
Structure and Nomenclature
}
Color: Red
Non-lighted LED lighting
Light source
• LED Lamp
Mounting Latches Switch Blocks Lighting unit
Contact Ratings
10 A at 100 VAC (resistive load) 10 A at 24 VDC (resistive load)
Lighting Method
Non-lighted Lighted (Direct lighting) Lighted (Voltage-reduction lighting)
Lock Plate (Attached with the Operation Unit)
(Refer to the "Mounting the Lock Plate" on page 15 for use.)
Operation Unit
Lamp
Switch
1.8
5.9
0.5
32
54.7
40 dia.
34
Medium Push-pull (40-dia.)
1.8
5.9
0.5
32
54.7
34
30 dia.
Small Turn-reset (30-dia.)
2
1.5
2
5.9
1.8
0.5
32
54.7
41.2
18.5
6.5
40 dia.
34
Note: The dimensions are the same as for EMO/EMS
indication models.
Medium Turn-reset (40-dia.)
1.8
5.9
0.5
32
54.7
60 dia.
34
Large Turn-reset (60-dia.)
A22E
Dimensions (Unit: mm)
Non-lighted Models
A22E-MP A22E-S
A22E-M A22E-L
Note: Unless otherwise specified, a tolerance of ±0.8mm applies to all dimensions.
11
Page 12
A22E
A22E A22NE-P
Common Note
Common Accessories and Tools
2
1.5
2
5.9
1.8
0.5
32
54.7
41.2
18.5
6.5
40 dia.
34
Medium Turn-reset (40-dia.)
Note: The operation unit is an example for the A22E-M.
10.6 dia.
9.5 dia.
20±1.5
BA9S/13
Model indication
4-4×38 tapping screw
22.1±
0.3
0.1
dia.
10
(10×36) 0.6 depression
75
20.5±0.1
2.8±0.1
68
36
Two, 21 dia.
(Side lead draw-out hole)
20
41
69.5
A22Z-B101Y (1-hole)
Cable Draw-out Hole (Top View)
Mounting Hole
Four, M4 Screws
22.1±
0.3
0.1
dia.
10
(10×36) 0.6 depression
68
2.8±0.1
68
36
20.5±0.1
Two, 21 dia. (Side lead draw-out hole)
30.5
60
16
A22Z-B201Y (1-hole)
Cable Draw-out Hole (Top View)
Mounting Hole
Lighted Model
A22EL-M
Note: Unless otherwise specified, a tolerance of ±0.8mm applies to all dimensions.
Accessories (Order Separately)
LED Lamp A22-6@, 12@, 24@
Switch dimensions when mounted to a 2NO (2NC) one-piece switch block
4424
57.8
72.7
Control Box
Control Box
Note: For details on the accessories common to the screw terminal block types and push-in plus terminal block types, refer to "Common
Accessories and Tools (Order Separately)" on page 32.
41
16±1 dia.
(Bottom lead draw-out hole)
Two, 19±1 dia.
(Bottom lead draw-out hole)
32
39
40
Two, mounting holes
56
Two, mounting holes
54
2-R3
4.3
6.3
2-R3
4.3
6.3
12
Page 13
A22E A22NE-P
Common Note
Common Accessories and Tools
Installation
Hold here
Mounting Ring
Lock Ring
Rubber Washer
Panel
Panel
Lock Ring
Projecting part
1. When the panel cutout dimension is
25 dia., remove the supplied rubber washer and mount the 25-dia. Ring as shown below. (Since the A22Z-R25 is not attached to the main body, order separately.) When using a Legend Plate (Order Separately), do not remove the rubber washer.
2. When the panel cutout
dimension is 30 dia., use resin attachment A22Z-A30. Since it is not attached to the main body, order separately.
Operation Unit
Rubber washer (mounted to Operation Unit)
30-dia. Resin Attachment (A22Z-A30)
Rubber washer (included)
Mounting panel
Lock Ring
Mounting Ring
Lever
Arrow mark
Operation Unit
• Move the lever in the direction indicated by the arrow in the following figure, then pull the Operation Unit or the Switch Blocks. Since the lever has a hole with an inside diameter of 6.5 mm, the lever can be moved in the specified direction by inserting a screwdriver into the hole and then moving the screwdriver.
Screwdriver
Mounting to the Panel
• The panel dimensions are shown below.
• The panel thickness must be 1 to 5 mm.
• Always use a 25-mm-dia. A22Z-R25 Lock Ring for a 25-mm-dia. hole. IP65 degree of protection will be lost if the 25-mm-dia. Lock Ring is not used because of the larger size of a 25-mm-dia. hole.
• When painting or coating the panel, make sure that the specified panel dimensions apply to the panel after painting or coating.
• Insert the Operation Unit into the Switch Unit, aligning the arrow mark inscribed on the Case with the lever on the Switch Blocks, then move the lever in the direction indicated by the arrow in the following figure.
(1) Preparing the Panel (2) Mounting the Operation Unit on the Panel
R0.8 max.
+0.2
3.2
0
+0.4
24.1
0
+0.4
22.3 dia.
0
+0.4
22.3 dia.
0
25 dia.
With Lock Ring Without Lock Ring
(3) Mounting the Switch on the Operation Unit
A22E
• Insert the Operation Unit from the front surface of the panel, insert the Lock Ring and the mounting Ring from the terminal side, then tighten the Ring. Before tightening, check that the rubber washer is present between the Operation Unit and the panel.
• Align the Lock Ring with the groove in the casing, then insert the Lock Ring so that its edge is located on the panel side.
• Tighten the mounting nut at a torque of 0.98 to 1.96 N·m.
• When using a Lock Ring, replace with the supplied Lock Ring, insert the projecting part into the lock slot, and then tighten the mounting Ring.
+0.5 0
(4) Removing the Switch
Assembling the Cap
• Insert the protrusion of the Tightening Wrench (A22Z-3905) into the Cap slot and then turn to remove the Cap.
Emergency Stop Switch
22 dia.
22.3 dia.
25 dia.
25 dia.
22.3 dia.
Operation Unit
Rubber washer (mounted to Operation Unit) When not using a Legend Plate, remove the rubber washer.
(If required) Legend Plates for Emergency Stop (order separately)
25-dia. Ring (A22Z-R25)
0.5 1.3
Panel
Lock Ring
Mounting Ring
Cap slot
Protrusion
13
Page 14
A22E
A22E A22NE-P
Common Note
Common Accessories and Tools
Snap-in Legend Plate
Mounting RIng
Rubber washer
Connector
Outside Inside
Box
Cable
Tightening cap
Cable diameter (mm)
Connector
7 to 9 dia. A22Z-3500-1 9 to 11 dia. A22Z-3500-2
Use either of the following screwdrivers.
Flat-head screwdriver
3 to 6 mm
3 to 6 mm dia.
Phillips screwdriver
Installing/Replacing the LED Lamp
Installing/Replacing on the Switch
• Grip the lamp with your fingers, then rotate the lamp while pressing it against the Switch.
Control Box (Enclosure)
(1) Mounting the Switch (2) Creating a Cable Port Hole (3) Securing the Connector Cable
The Standard-size Legend Plate Frame can be mounted. Mount the Frame as shown in the following diagram. Mount the Switch in the same way as for an ordinary panel.
Place the tip of a screwdriver on the surface where the cable port hole is to be created with the cover attached and strike the screwdriver to punch a hole. Attempts to punch a hole on the other side of the case will damage the Box.
1. Insert the connector into the cable port hole in the Box and secure with the Mounting Ring inside the box.
2. Pass the tightening cap through the cable, insert the cable into the connector, and tighten the tightening cap to secure the cable.
Installing/Removing the Switch Blocks Wiring
(1) Installing the Switch Blocks (2) Removing the Switch Blocks Wiring Round Crimp Terminals
• Hook the small protrusion on the Mounting Latch into the groove on the other side of the lever, then push up the Switch Block in the direction indicated by the arrow in the figure below.
Lever
Mounting Latches
Switch Blocks
Protrusion
Insert a screwdriver between the Mounting Latch and the Switch Block, then push down the screw­driver in the direction indicated by the arrow in the following figure.
Screwdriver
• Loosen the terminal screw from the Switch Unit until it completely comes off the groove, insert a screwdriver as shown in the following figure, then push up the washer in the direc­tion indicated by the arrow to temporarily secure it. Now, a round crimp terminal can be con­nected. After inserting the terminal, tighten the screws to complete wiring.
Washer
Screw
Screwdriver
14
Page 15
A22E A22NE-P
Common Note
Common Accessories and Tools
Safety Precautions
CAUTION
Lever
Operation Unit
Mounting Latch
Lock Plate
1
2
Naked Crimp Terminals
8 mm max.
16.0 mm max.
8 mm dia. max.
16.0 mm max.
Crimp Terminals with Insulating Sheaths
20.2 mm max.
8 mm max.
20.2 mm max.
8 mm dia. max.
X1
X2
LED lamp
R:10kΩ (1W) Bleeder resistor
(Circuit example)
In case of using 24 VAC/VDC, Direct lighting
Invalid area
0.1 1 10 100 1,000
10 mA
1 mA
5
12
24
30
0.16 mA
1.6 mA
100 mA
0
Voltage (V)
Microload area
Area of use
Standard load area
Current (mA)
Be sure to read the precautions for All PushButton Switches in the website at:http://www.ia.omron.com/.
Indication and Meaning for Safe Use
Precautions
for Safe Use
If the Operation Unit is separated from the Socket Unit, the equipment will not stop, creating a hazardous condition. Secure the lever on the Socket Unit by using the A22Z-3380 Lock Plate so that the Operation Unit cannot be easily separated from the Socket Unit. (Refer to “Mounting the Lock Plate” at the below.)
Mounting the Lock Plate
1. Confirm that the lever on the Mounting Latch is on the side where
the Operation Unit is secured and then insert the protrusion on the Lock Plate into the hole in the lever on the Mounting Latch.
2. Press the hole on the Lock Plate onto the protrusion on the Mounting Latch until it clicks into place.
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or in property damage.
Supplementary comments on what to do or avoid doing, to use the product safely.
Caution
Precautions for Correct Use
A22E
LED Lamps
• The LED current-limiting resistor is built-in, so internal resistance is not required.
• If commercially available LEDs are used, select the ones that meet the following conditions: Base: BA9S/13 Overall length: 26 mm max. Power consumption: 2.6 W max. When DC-specific LEDs are used, wire the Switch so that the X1 terminal is positive.
• Mis-lighting of the LED The LED lights with approx. 0.1 mA or less of micro-current. Take a countermeasure like adding a resistor to prevent mis-lighting in parallel to the LED. The micro-current varies with the machine (leak current or stray capacity between cables, etc.). Select resistance value and allowable power consumption that meet the actual current.
• Do not use a lamp that does not satisfy the rating.
Wiring
• Terminal screws must be Phillips or slotted M3.5 screws with a square washer.
• The tightening torque is 1.08 to 1.27 N·m.
• Single wires, stranded wires, and crimp terminals can be connected to the Switch.
• Applicable Wiring Materials: Twisted strands: 2 mm
2
max.
Solid wire: 1.6 mm dia. max.
Using the Microload
Contact failure may occur if a Switch designed for a standard load is used to switch a microload. Use Switches within the application ranges shown in the following graph. Even within the application range, insert a contact protection circuit, if necessary, to prevent the reduction of life expectancy due to extreme wear on the contacts caused by loads where inrush current occurs when the contact is opened and closed. The minimum applicable load is the N-level reference value. This value indicates the malfunction reference level for the reliability level of 60% (λ The equation, λ malfunction rate is less than 1/2,000,000 with a reliability level of 60%.
Be sure to read the "Safety Precautions" on page 37.
60) (conforming to JIS C5003). 60 = 0.5 x 10
6
/time indicates that the estimated
• After wiring the Switch, maintain an appropriate clearance and creepage distance.
15
Page 16
A22E A22NE-P
Common Accessories and Tools
Common Note
Emergency Stop Pushbutton Switches (22-dia. or 25-dia.) with Push-In Plus technology
For the most recent information on models that have been certified for safety standards, refer to your OMRON website.
2. Reset function
4. Contacts
5. LED lamp voltage
1. Operation Unit size (diameter)
Code Description
None Turn-reset
PPull-reset *
Code
Description
LED Lamp Voltage
Lighted
(LED) *
N Non-lighted
---
A
B
* Lighting color is red.
* The pull-reset type is only available on the 40 dia.
Operation Unit, non-lighted type. Not available on lighted types.
A22NE- ---
65421
6. Others
Code Configuration
None
Standard
B
* Built-in control box
* One-contact unit type.
3. Contact specification/Terminal specification
Code Description
P Standard load/Push-in plus terminal block
Code
Description
S30
dia.
M40 dia.
L 60 dia.
C
D
E
6 VAC/DC
12 VAC/DC
24 VAC/DC
200/220/230/240 VAC
100/110/120 VAC
3
Note 1. NO: 1a-contact NC: 1b-contact
2. For details on the unit position, refer to the figure below.
Code
Number of
Switch Blocks
Unit position
Non-lighted Lighted
NO NC 1 2 3 1 2 3
002 0 1 --- ---
NC --- Lighting unit NC
102 1 1
NC NO Lighting unit NC
202 0 2
NC --- NC NC Lighting unit NC
212 1 2
NC NO NC
222 0 3
NC NC NC
---
NO ---
(Example: A22NE-M-P102-N)
A22NE-P
Install in 22-dia. or 25-dia. Panel Cutout
(When Using a Ring)
• The small size of the control panel is realized by conserving space and changing the direction of the wiring.
• Since there is no looseness in the wiring, there is a reduction in the maintenance efforts.
• A lock lever mechanism that can be easily operated is adopted.
• A maximum of up to six contact points can be combined together in the contact-point configuration.
• Oil-resistant to IP65 (non-lighted models) / IP65 (lighted models).
Be sure to read the "Safety Precautions" on pages 28 and 37.
Model Number Structure
Model Number Legend (Completely Assembled)........Shipped as a set which includes the Operation Unit, LED
Lamp (lighted model only), Mounting Latches, Lighting Units (lighted model only), and Switch Block.
16
Page 17
A22E A22NE-P
Common Note
Common Accessories and Tools
Ordering Information
40-dia. head Medium Pull-reset A22NE-MP-P@@2-N
30-dia. head Small Turn-reset A22NE-S-P@@2-N
40-dia. head Medium Turn-reset A22NE-M-P@@2-N
60-dia. Large Turn-reset A22NE-L-P@@2-N
40-dia. head Medium Turn-reset A22NE-M-P@@2-A
40-dia. head Medium Turn-reset A22NE-M-P@@2-B
40-dia. head Medium Turn-reset A22NE-M-P@@2-C
40-dia. head Medium Turn-reset A22NE-M-P@@2-D
40-dia. head Medium Turn-reset A22NE-M-P@@2-E
Non-lighted Models
Appearance
Operation
Contact configuration
(Number of switch blocks)
1NC (1) A22NE-MP-P002-N
1NC, 1NO (2) A22NE-MP-P102-N
2NC (2) A22NE-MP-P202-N
2NC, 1NO (3)
3NC (3) A22NE-MP-P222-N 1NC (1) A22NE-S-P002-N
1NC, 1NO (2) A22NE-S-P102-N
2NC (2) A22NE-S-P202-N
2NC, 1NO (3)
3NC (3) A22NE-S-P222-N 1NC (1) A22NE-M-P002-N
1NC, 1NO (2) A22NE-M-P102-N
2NC (2) A22NE-M-P202-N
2NC, 1NO (3)
3NC (3) A22NE-M-P222-N 1NC (1) A22NE-L-P002-N
1NC, 1NO (2) A22NE-L-P102-N
2NC (2) A22NE-L-P202-N
2NC, 1NO (3)
3NC (3) A22NE-L-P222-N
A22NE-MP-P212-N
A22NE-S-P212-N
A22NE-M-P212-N
A22NE-L-P212-N
A22NE-P
Set Model Color of cap
Red
Lighted Model
Appearance
Operation
Contacts
(Number of switch blocks)
1NC (1)
1NC, 1NO (2) A22NE-M-P102-A
2NC (2) A22NE-M-P202-A
1NC (1)
1NC, 1NO (2) A22NE-M-P102-B
2NC (2) A22NE-M-P202-B
1NC (1)
1NC, 1NO (2) A22NE-M-P102-C
2NC (2) A22NE-M-P202-C
1NC (1)
1NC, 1NO (2) A22NE-M-P102-D
2NC (2) A22NE-M-P202-D
1NC (1)
1NC, 1NO (2) A22NE-M-P102-E
2NC (2) A22NE-M-P202-E
LED lamp voltage
6 VAC/VDC
12 VAC/VDC
24 VAC/VDC
100, 110, 120 VAC
220, 230, 240 VAC
Set Model Color of cap
A22NE-M-P002-A
A22NE-M-P002-B
A22NE-M-P002-C
Red
A22NE-M-P002-D
A22NE-M-P002-E
Switch with Integrated Control Box
Appearance
Contact configuration
(Number of switch blocks)
1NC (1) A22NE-M-P002-N-B
1NC, 1NO (2) A22NE-M-P102-N-B
2NC (2) A22NE-M-P202-N-B
Model
17
Page 18
A22NE-P
A22E A22NE-P
Common Accessories and Tools
Common Note
Operation Unit Operation Unit
Non-lighted Lighted
Switch Blocks *
LED Lamp
Mounting Latches
Push-in Plus Terminal Block Push-in Plus Terminal Block
Switch Blocks + Lighting Unit
Subassembled........The Operation Unit, LED Lamp, Mounting Latches, Switch Blocks, and Lighting Unit can be ordered separately. Use
them in combination for models that are not available as assembled Units. These can also be used as inventory for maintenance parts.
* Up to three Switch Blocks can be mounted for multiple contacts.
18
Page 19
A22NE-P
A22E A22NE-P
Common Note
Common Accessories and Tools
Operation Unit
Non-lighted
Sealing capability IP65 oil-resistant models
Function Size Small (30 dia.) Medium (40 dia.) Large (60-dia.)
A22NE-MP-N
Pull-reset ---
Turn-reset
A22NE-S-N
A22NE-M-N
A22NE-MRO-N A22NE-MRO-N-RD
A22NE-MRS-N A22NE-MRS-N-RD
---
A22NE-L-N
Lighted
Sealing capability IP65
Function Size Medium (40 dia.)
Turn-reset
LED lamp
Appearance LED light Rated voltage Model Remarks
Red
A22NE-M-L
6 VAC/VDC A22NZ-L-RA
12 VAC/VDC A22NZ-L-RB
24 VAC/VDC A22NZ-L-RC
100, 110, 120 VAC A22NZ-L-RD
200, 220, 230, 240 VAC A22NZ-L-RE
These LED lamps are for exclusive use with the A22N and the A22NE-P. These are provided with the completely assembled set of lighted models. Order LED lamps only when replacing them.
19
Page 20
A22NE-P
A22E A22NE-P
Common Accessories and Tools
Common Note
Accessories (Order Separately)
Item Appearance Contact specifications Model Remarks
Switch Blocks (one contact)
Switch Blocks (two contacts)
Lighting unit
Mounting Latches
Control Boxes (Enclosures)
1NO (Blue) Standard load A22NZ-S-P1AN
1NC (Red) Standard load A22NZ-S-P1BN
2NC (Red) Standard load A22NZ-S-P2BN
1NO/1NC (White)
6 VAC/VDC A22NZ-T-APN 12 VAC/VDC A22NZ-T-BPN 24 VAC/VDC A22NZ-T-CPN 100, 110, 120 VAC A22NZ-T-DPN 200, 220, 230, 240 VAC A22NZ-T-EPN
One hole, yellow box A22NZ-A-B01Y
Standard load A22NZ-S-P2CN
--- A22NZ-H-02
Provided as standard. Order Switch Blocks only when adding or replacing them.
Order Switch Blocks only when adding or replacing them.
These are provided with the completely assembled set of lighted models. Order Lighting Units only when replacing them.
This Mounting Latch is for exclusive use with the A22NE-P. It is provided with the completely assembled set. Order Mounting Latches only when mounting Switch Blocks or Lighting Units that are purchased individually.
Material: Polycarbonate resin. Can be used only with a one­contact Switch Block.
*
Note: For details on the accessories common to the screw terminal block types and push-in plus terminal block types, refer to "Common
Accessories and Tools (Order Separately)" on page 32.
* The A22NZ-A-B01Y Control Box cannot be used in combination with the A22Z-3476-1 90-dia. Legend Plates for Emergency Stop or the A22Z-
EG@ E-stop Shrouds.
20
Page 21
A22E A22NE-P
Common Note
Common Accessories and Tools
Specifications
A22NE-P
Certified Standard Ratings
• UL508 (File No. E76675), CSA C22.2 No.14 6 A at 240 VAC, 10 A at 120 VAC
• TÜV (EN60947-5-1) - Certified direct opening -
AC-15 3 A at 240 VAC DC-13 4 A at 24 VDC
• CCC (GB14048.5) AC-15 3 A at 240 VAC DC-13 4 A at 24 VDC
Applicable Standards
UL1059, UL486E (Push-in Plus Terminal Block Types)
Note: Use a 10 A fuse type gI or gG that conforms to IEC60269 as a
Ratings
Contacts (Standard Load)
Rated
insulation
voltage (V)
600 10
(EN60947-5-5)
short-circuit protection device. This fuse is not provided in the main unit.
Rated current (A)
(Resistive
load)
--- ---
AC12
load)
DC13
(Inductive
load)
DC12
(Resistive
load)
--- ---
48
2.2
1.1
Rated carry
current (A)
Rated
voltage
24 VAC 10 10 120 VAC 6 10 240 VAC 3 6 380 VAC 1.9 2 440 VAC 1.6 2 24 VDC 120 VDC 1.1 240 VDC 0.55
(V)
AC15
(Inductive
Certified Standards
Certification
body
UL *
TÜV SÜD
CQC (CCC) GB14048.5 2017010305959182
Note: Only models with NC contacts have a direct opening
mechanism.
* UL-certification for CSA C22.2 No. 14 has been obtained.
LED Lamp
Rated voltage Operating voltage Current value
6 VAC/VDC 6 VAC/VDC ± 10% Approx. 11 mA 12 VAC/VDC 12 VAC/VDC ± 10% Approx. 12 mA 24 VAC/VDC 24 VAC/VDC ± 10% Approx. 12 mA
100 VAC 100 VAC ± 10%
120 VAC 100 VAC to 130 VAC 200 VAC 200 VAC ± 10% 220 VAC 220 VAC ± 10% 230 VAC 230 VAC ± 10% 240 VAC 220 VAC to 250 VAC
Standards File No.
UL508, C22.2 No.14
EN60947-5-1
(Certified direct opening),
EN60947-5-5
Consult your OMRON representative for details.
E76675
Approx. 12 mA110 VAC 110 VAC ± 10%
Approx. 12 mA
Note: 1. The above ratings were obtained by conducting tests under
the following conditions. (1) Ambient temperature: 20°±2°C (2) Ambient humidity: 65±5%
(3) Operating frequency: 30 operations/minute
2. Minimum applicable load: 10 mA at 5 VDC (Resistive load) The operating range may vary depending on the usage conditions and type of load.
21
Page 22
A22NE-P
A22E A22NE-P
Common Accessories and Tools
Common Note
Lock lever
Lighting unit
Terminal (insertion) hole
(17.6°)
(20°)
10
20
31.9
4
Switch Blocks
Characteristics
Type Turn-reset Pull-reset
Item Non-lighted model Lighted Model Non-lighted model
Allowable operating frequency
Insulation resistance *1 100 MΩ min. (at 500 VDC) Contact resistance 100 mΩ max. (initial value)
Dielectric strength
Vibration resistance Malfunction 10 to 55 Hz, 1.5 mm double amplitude (contact separation within 1 ms) Shock resistance Malfunction 250 m/s2 max. (contact separation within 1 ms)
Durability
Ambient operating temperature *2 -20 to +70°C -20 to +55°C -20 to +70°C Ambient operating humidity 35 to 85% RH Ambient storage temperature *2 -40 to +70°C Degree of protection*3 IP65 (oil-resistant) *4 IP65 IP65 (oil-resistant) *4 Electric shock protection class Class II PTI (tracking characteristic) 175 Degree of contamination 3 (EN 60947-5-1) Minimum direct opening stroke 11 mm Minimum direct opening force 45 N Conditional short-circuit current 100 A (EN 60947-5-1)
Wight (for a 40-dia. head 1NC/1NO Operation Unit)
*1. State when an LED is not added between terminals of the same polarity on a lighting unit. Does not apply to lighted-type 100 to 200 V lighting
units.
*2. With no icing or condensation. *3. The degree of protection from the front of the panel. *4. The degree of protection is IP65 even with an integrated control box, but the system is not oil resistant.
Mechanical 30 operations/minute or less (One operation consists of set and reset operations.) Electrical 30 operations/minute or less (One operation consists of set and reset operations.)
Between terminals of same polarity
*1
Between each terminal and ground
2,500 VAC, 50/60 Hz 1 minute (initial value)
2,500 VAC, 50/60 Hz 1 minute (initial value)
Mechanical 300,000 operations min. (One operation consists of set and reset operations.) Electrical 300,000 operations min. (One operation consists of set and reset operations.)
Approx. 55g Approx. 60g Approx. 85 g
Operating Characteristics
Item Turn-reset Pull-reset Total travel force (TTF) 45 N max. 60 N max. Return force (RF) 0.25N·m * max. 60 N max. Total travel (TT) 10 ±1 mm 5.5 ±1 mm
* Rotation torque value.
Terminal Arrangement (BOTTOM VIEW)
Non-lighted (two contacts) Non-lighted (three contacts) Lighted (two contacts)
Terminal (insertion) hole
Switch Blocks
(17.6°)
(20°)
10
20
Lock lever
31.9
4
Terminal (insertion) hole
Switch Blocks
(17.6°)
(20°)
Lock lever
31.9
10
4
20
22
Page 23
A22E A22NE-P
Common Note
Common Accessories and Tools
Terminal connection
1
2
1
2
NC NC
3
4
121
2
NC NONC
1
2
X2
X1
X
(-)
(+)
3
4
1
2
1
2
X2
X1
X
(-)
(+)
B
A
Type
Terminal Connection (BOTTOM VIEW)
2NC (two contacts) 1NC, 1NO (two contacts)
A
B
22
21
14
13
}
Color: Red
Non-lighted LED lighting
Light source
• LED Lamp
Mounting Latches Switch Blocks Lighting unit
Contact Ratings
6 A at 240 VAC 10 A at 120 VAC
Lighting Method
Non-lighted Lighted (LED)
Operation Unit
Lamp
Switch
Type
Non-lighted
A22NE-P
Terminal Connection (BOTTOM VIEW)
1NC, 1NO (two contacts) 2NC (two contacts) 2NC, 1NO (three contacts) 3NC (three contacts)
NC NO
1
3
NC NCNC
12121
Lighted
Note: The above terminal connection diagrams are examples for 1NO, 1NC (two contacts), or 2NC (two contacts).
Terminal wiring drawings of two-contact Switch Units
2
4
21
22
11
12
2
Structure and Nomenclature
23
Page 24
A22NE-P
A22E A22NE-P
Common Accessories and Tools
Common Note
1.8
5.9
0.5
32
39.5
40 dia.
42.5
Pull-reset (40-dia.)
1.8
5.9
0.5
32
39.5
30 dia.
42.5
Small Turn-reset (30-dia.)
1.8
5.9
0.5
32
39.5
40 dia.
42.5
Note: The dimensions the same even if the Operation Unit is replaced
with the A22NE-MR@-N or the A22NE-MR@-N-RD.
Medium Turn-reset (40-dia.)
60 dia.
1.8
5.9
0.5
32
39.5
42.5
Large Turn-reset (60-dia.)
Medium Turn-reset (40-dia.)
40 dia.
0.5
1.8
5.9
55
44
32
Dimensions (Unit: mm)
Non-lighted Models
A22NE-MP-P@@2-N A22NE-S-P@@2-N
A22NE-M-P@@2-N
Lighted Model
A22NE-M-P@@2-@
40 dia.
0.5
32
A22NE-L-P@@2-N
42.5
1.8
5.9
39.5
Note: Unless otherwise specified, a tolerance of ±0.8mm applies to all dimensions.
Dimensions when a two-contact Switch Block is attached
24
Page 25
A22E A22NE-P
Common Note
Common Accessories and Tools
Accessories (Order Separately)
Switch Block (one contact)
A22NZ-S-P1@N
47.6
39.3
31.9
5
9.9
4
Switch Block (two contacts)
A22NZ-S-P2@N
Lighting unit
A22NZ-T-@PN
51.3
17.1
R29.5
30
Mounting Latches
A22NZ-H-02
LED Lamp A22NZ-L-@@
Control Box A22NZ-A-B01Y
Switch Block with Push-In Plus technology
4
47.6
12 dia.
16.4
16.4
A22NE-P
5
23.8
9.9
26.4
23.8
47.6
24.3
9.8 dia. 9 dia.
Four, M4 Phillips binding screws
24.2
24.2
3.2
80
22.3 dia.
9.9
Four, 3.7-dia.
40
10
10
40
59.9
Case (Black)
38
Two, 21.4 dia. (Side lead hole)
18.5
62
Cover (Yellow)
80
3.2
(M4-tapped holes)
Two, 14-dia. (Bottom lead hole)
Two, 4.4-dia.
(oval mounting hole)
5.4
Note: For details on the accessories common to the screw terminal block types and push-in plus terminal block types, refer to "Common
Accessories and Tools (Order Separately)" on page 32.
25
Page 26
A22NE-P
A22E A22NE-P
Common Accessories and Tools
Common Note
Panel hole dimension Panel thickness
22.3 dia. 1 to 5 mm
22.3 dia.
+0.4
0
22.3 dia.
+0.4
0
R0.8 max.
+0.2 0
3.2
24.1
+0.4 0
25 dia.
+0.5
0
Rubber Washer
22.3 dia.
Lock Ring
Mounting Ring
Panel
Tightening Wrench (order separately, A22Z-3905)
Lock Ring
Panel
Rubber washer
Mounting Ring
Hold here
When the A22Z-3360 Lock Ring (Order Separately) is used
• Take note of the direction when mounting the Lock Ring.
25-dia. Ring A22Z-R25
Operation Unit
Panel
Lock Ring
Mounting Ring
22.3 dia.
22.3 dia.
1.30.5
25 dia.
22.3 dia.
22 dia.
Rubber washer (provided with the Operation Unit)
Panel Hole of 25.5-mm Diameter
• Insert the A22Z-R25 (Order Separately) between the Operation Unit and Panel, and tighten the clamping nut to mount. Before tightening, check that the rubber washer supplied with the Operation Unit is present between the Operation Unit and the 25-dia. Ring.
Panel Hole of 30-mm Diameter
Insert the A22Z-R30 (Order Separately) between the Operation Unit and Panel, and tighten the clamping nut to mount. Before tightening, check that the supplied rubber washer is present between the Operation Unit and the panel, and between the 30-dia. Resin Attachment and the panel. Recommended panel thickness: 1 to 3 mm
Type of operation unit
Dimension A (mm)
min.
Dimension B (mm)
min.
30-dia., 40-dia. models 50 *150 60-dia. model 70 70
Dimension A
R0.8 max.
+0.4 0
+0.4 0
22.3 dia.
24.1
+0.4 0
+0.2 0
3.2
Using the Lock Ring
Standard switch
Panel Hole Dimensions for 22.3 Diameter
Dimension B
+0.4 0
22.3 dia. 22.3 dia.
Application
Mounting to the Panel
(1) Preparing the Panel (3) Mounting the Operation Unit on the Panel
Panel hole dimension and panel thickness
• If outer surface treatment such as coating is performed for the panel, the panel dimensions after outer surface treatment must meet the specified panel dimensions.
When using a A22Z-3360 (Order Separately) Lock Ring
• Do not tighten the Mounting Nut more than necessary using tools such as pointed-nose pliers.
• Doing so will damage the Mounting Nut. (The tightening torque of the Mounting Nut is 1.0 to 2.0 N·m.) Tightening Wrench: A22Z-3905
Panel Hole of 22.3-mm Diameter
• Insert the Operation Unit from the front of the panel, insert the Lock Ring and Mounting Nut from the back of the panel, and tighten the Mounting Nut. Before tightening, check that the rubber washer is present between the Operation Unit and the panel.
For 25-dia.
• Use the A22Z-R25 (Order Separately) rubber ring.
(2) Minimum mounting pitch (Dimension A, Dimension B)
Minimum mounting pitch
*1. If the Mounting Collar lock levers all face the same direction at the
minimum mounting pitch, be sure to note the order the mounting collars are attached to the Operation Unit.
*2. When using each accessory (Order Separately), set the A and B
dimensions in view of the dimensions of the accessories.
*3. Make sure the mounting pitch does not hinder the operation.
26
Panel
Projecting part
Lock Ring
Operation Unit
Rubber Washer (provided with the Operation Unit)
30-dia. Resin Attachment A22Z-A30
Rubber Washer (included)
Mounting Panel
Lock Ring
Mounting Ring
Page 27
A22NE-P
A22E A22NE-P
Common Note
Common Accessories and Tools
(1)
(3)
(2)
(1)
2
1
Switch Box
Screwdriver
Groove
Side
Strike at four diagonally opposed locations to open the hole.
Cover
Cable Hole
Cable diameter
(mm)
Connector
7 to 9 dia. A22Z-3500-1 9 to 11 dia. A22Z-3500-2
Removing the Mounting Latch
• Press the lock lever in from the back side to release the lock, and then hook the Mounting Collar with a screwdriver, move it in the direction indicated at (2), and remove it. Turn the lever all of the way until it clicks into place.
Switch Blocks and Lighting Unit
• Catch the projection on the opposite side of the Mounting Collar from the lever side and press the Switch Block in the direction indicated at (1).
When the Mounting Latch is to be Removed
(1) Installing the Switch Blocks and Lighting Unit
Attaching the LED Lamp to the Lighting Unit
When the LED Lamp is to be Installed
• Insert the protrusions on the LED Lamp into the guides on the Lighting Unit and then turn the LED Lamp in direction (2) to lock it in place.
Control Box
(1) Mounting the Switch
Mount the Switch in the same way as for a standard panel. The tightening torque of the Box screws is 1.4 to 2.0 N·m.
Legend Plate
(2) Removing the Switch Blocks and Lighting Units
• Insert a screwdriver into the gap between the Mounting Collar and Switch Block and press it inward in the direction shown at (2).
(3)
(1)
(2)
(2) Creating a Cable Hole
To open a cable hole, leave the cover attached, place the tip of a screwdriver in the grooves at four locations around the cable hole, and strike the screwdriver with a hammer to open the hole.
(3) Securing the Connector Cable
1. Insert the connector into the cable port hole in the Box and
secure with the fixing nut inside the box.
2. Open a hole in the thin rubber section of the rubber ring.
3. Pass the tightening cap through the cable, insert the cable into
the connector, and tighten the hexagonal nut to secure the cable.
Rubber washer
Mounting RIng
Panel
Connector
Tightening cap
Cable
27
Page 28
A22NE-P
A22E A22NE-P
Common Accessories and Tools
Common Note
1
2
Mounting Latches
Operation Unit
Lock lever
Mounting Latches
Switch Blocks
Safety Precautions
Be sure to read the precautions for All PushButton Switches in the website at: http://www.ia.omron.com/.
Indication and Meaning for Safe Use
Precautions
for Safe Use
Precautions
for Correct
Use
Comments on what to do or avoid doing, to use the product safely.
Supplementary comments on what to do or avoid doing to use the product safely and prevent its malfunctioning or an adverse effect on its performance or functions.
Precautions for Safe Use
• If the Operation Unit is separated from the Switch Units, the equipment will not stop, resulting in a hazardous situation. Make sure the Operation Unit, Mounting Latches, and the Switch Units are properly assembled.
<Assembling the Operation Unit and the Mounting Latches> Align the TOP indication (the mark) on the Operation Unit with the TOP indication on the Mounting Latches to fit it properly, and turn the lock lever on the Mounting Latch in the direction shown in the figure below until a clicking sound is heard.
<Assembling the Mounting Latches and Switch Blocks> Make sure the hooking part (convex part) on the Mounting Latches is perfectly latched into the hooking part (concave part) on the Switch Block.
• Do not use the Switch/Indicator in locations where explosive or flammable gases or liquid may be present or scattered. The electric ark or the heat caused by switching contacts may cause a fire or explosion.
• Do not use the Switch/Indicator in locations where toxic gases, such as H locations subject to high temperature or humidity. Doing so may damage the Switch/Indicator due to contact failure or corrosion.
• Do not use the Switch/Indicator submersed in oil or water, or in locations continuously subject to splashes of oil or water. Doing so may result in oil or water entering and damaging the Switch/ Indicator.
• Do not use or keep the Switch/Indicator under the following conditions:
Subject to severe temperature changes.
Subject to high humidity or condensation.
Subject to severe vibration or shock.
Where direct rays of the sun strike.
Where sea breeze may be present.
• Make sure that a rubber washer is present between the Operation Unit and the panel. Otherwise, the specifications of the protective structure may not be satisfied.
• Do not apply excessive force to the Switch or wirings. Damage or deformation of the Switch Block could cause an improper contact or a loss of safety.
• Use an appropriate wiring and crimp terminals (hereinafter, called ferrule terminals).
• Exercise caution to avoid wiring errors when connecting the terminals.
• To prevent wiring materials from smoking or ignition, confirm wire ratings and use the wiring materials given in the following table.
Solid wire/ Stranded Wire
Use wiring crimp terminals and ferrule terminals of the specified size.
• After storing the product for a long time exceeding 1 year, perform, at a minimum, inspections of the operating characteristics, contact resistance, insulation resistance, and dielectric strength as well as evaluate the product under the working conditions.
• This Switch/Indicator is intended for indoor use only. Using the Switch/Indicator outdoors may result in failure.
2S, SO2, NH3, HNO3, and Cl2, may be present, or in
Wire
Wire Type
material
Copper
Recommended
Wire
0.25 to 1.5 mm AWG 24 to 16
2
Wire coating peeling
amount
Ferrules used: 10 to 12 mm (Varies depending on the recommended ferrule conductor length) Ferrules not used: 8 mm
• When transition wiring is performed, make sure the switching current inside the Switch and the current based on the transition wiring is below the rated current of the Switch. If a current value higher than the rated current flows, it could result in emission of heat, or damage and deformation of the Switch, which could cause fire and locking of the contact, and thus a loss of safety.
• Do not perform wiring with power supplied to the Switch/Indicator. Do not touch the terminals or other charged parts while power is being supplied. Doing so may result in electric shock.
• Do not disassemble or modify the Switch/Indicator under any circumstances.
• Doing so may prevent the Switch/Indicator from functioning to its full capability. Do not drop the Switch/Indicator. Do not apply pressure that may deform or alter the Switch/Indicator.
• The durability of the Switch varies considerably depending on the switching conditions. Always test the Switch/Indicator under actual working conditions before application and use the Switch/Indicator
only for the number of switching operations allowed.
• Do not allow the load voltage and current to exceed the rated value. This may damage or burn out the Switch/Indicator.
28
Page 29
A22NE-P
A22E A22NE-P
Common Note
Common Accessories and Tools
Ferrule or solid wire
Approx. 6˚
Approx. 6˚
The wiring for the Lighting Unit and Switch Block (2 contacts) are the same as for the Switch Block (1 contact) shown in the above illustra­tion.
Do not wire anything to the release holes.
Do not tilt or twist a flat-blade screwdriver while it is inserted into a
release hole on the terminal block. The terminal block may be damaged.
• Insert a flat-blade screwdriver into the release holes at an angle. The terminal block may be damaged if you insert the screwdriver straight in.
Do not allow the flat-blade screwdriver to fall out while it is inserted into a release hole.
• Do not bend a wire past its natural bending radius or pull on it with excessive force. Doing so may cause the wire disconnection.
• Do not insert more than one wire into each terminal insertion hole.
• Do not mount A22N-P or A22NE-P Push-In Plus terminal switch blocks on A22N screw terminal blocks. Doing so may result in unsatisfactory performance.
Precautions for Correct Use
Wiring
1. Connecting Wires to the Push-In Plus Terminal Block
Part Names of the Terminal Block
Terminal (insertion) hole
Release hole
Terminal (insertion) hole
Connecting Wires with Ferrules and Solid Wires
• Insert the solid wire or ferrule straight into the terminal block until the end strikes the terminal block. The angle should be approximately 6°.
• If a wire is difficult to connect because it is too thin, use a flat-blade screwdriver in the same way as when connecting stranded wires.
29
Page 30
A22NE-P
A22E A22NE-P
Common Accessories and Tools
Common Note
Approx. 6˚
(2)
Approx. 6˚
(1)
(3)
Flat-blade screwdriver
Approx. 6˚
The wiring and screwdriver angles for the Lighting Unit and Switch Block (2 contacts) are the same as for the Switch Block (1 contact) shown in the above illustration.
Approx. 6˚
(2)
Approx. 6˚
(1)
(3)
Flat-blade screwdriver
Approx. 6˚
The wiring and screwdriver angles for the Lighting Unit and Switch Block (2 contacts) are the same as for the Switch Block (1 contact) shown in the above illustration.
8 to 10 mm
Max. 1.9 mm
Max. 2.6 mm
Side view
0.4 mm
2.5 mm dia.
2.5 mm
Front view
Connecting Stranded Wires
Use the following procedure to connect the wires to the terminal block.
1. Hold a flat-blade screwdriver at an angle and insert it into the release hole. The angle should be approximately 6°. If the flat-blade screwdriver is inserted correctly, you will feel the spring in the release hole.
2. With the flat-blade screwdriver still inserted into the release hole, insert the wire into the terminal hole until the end strikes the terminal block.
3. Remove the flat-blade screwdriver from the release hole.
Checking Connections
• After the insertion, pull gently on the wire to make sure that it will not come off and it is securely fastened to the terminal block.
• If you use a ferrule with a conductor length of 10 mm, part of the conductor may be visible after the ferrule is inserted into the terminal block, but the product insulation distance will still be satisfied.
2. Removing Wires from the Push-In Plus Terminal Block
Use the following procedure to remove wires from the terminal block. The same method is used to remove stranded wires, solid wires, and ferrules.
1. Hold a flat-blade screwdriver at an angle and insert it into the release hole. The angle should be approximately 6°.
2. With the flat-blade screwdriver still inserted into the release hole, remove the wire from the terminal insertion hole.
3. Remove the flat-blade screwdriver from the release hole.
3. Recommended Ferrules and Crimp Tools Coating peeling amount
Recommend Wire Type
0.25 to 1.5 mm
2
/AWG 24 to AWG 16 8 mm
Stripping length
(Ferrules not used)
Recommended ferrules
Applicable
wire
(mm2)
0.25 24
0.34 22
0.5 20
0.75 18
1/1.25
1.25/1.5
Recommended Crimp Tools
(AWG)
18/17
17/16
Ferrule
conductor
length
(mm)
Stripping
length (mm)
(Ferrules not
used)
8 10 AI 0, 25-8 H0.25/12 216-301
10 12 AI 0, 25-10 --- ---
8 10 AI 0, 34-8 H0.34/12 216-302
10 12 AI 0, 34-10 --- ---
8 10 AI 0, 5-8 H0.5/14 216-201
10 12 AI 0, 5-10 H0.5/16 216-241
8 10 AI 0, 75-8 H0.75/14 216-202
10 12 AI 0, 75-10 H0.75/16 216-242
8 10 AI 1-8 H1.0/14 216-203
10 12 AI 1-10 H1.0/16 216-243
8 10 AI 1, 5-8 H1.5/14 216-204
10 12 AI 1, 5-10 H1.5/16 216-244
Note: 1. Make sure that the outer diameter of the wire coating is
smaller than the inner diameter of the insulation sleeve of the recommended ferrule.
2. Make sure that the ferrule processing dimensions conform to the following figures.
Recommended ferrules
Phoenix Contact product
CRIMPFOX6 CRIMPFOX6T-F CRIMPFOX10S
Weidmuller
PZ6 roto
product
Wago
product
Variocri mp4
Recommended Flat-Blade Screwdrivers
Use a flat-blade screwdriver to connect and remove wires. Use one of the following flat-blade screwdrivers. The following table shows manufacturers and models as of 2015/Dec.
30
Model Manufacture
ESD 0,40 × 2,5 Wera
SZS 0,4 × 2,5 SZF 0-0,4 × 2,5 *
0.4 × 2.5 × 75 302 Wiha
AEF.2,5 × 75 Facom
210-719 Wago
SDI 0,4 × 2,5 × 75 Weidmuller
*
The SZF 0-0,4 × 2,5 (manufactured by Phoenix Contact) can be
Phoenix Contact
procured through an OMRON exclusive purchase form (XW4Z-00B).
• After wiring the Switch/Indicator, provide a sufficient insulation distance.
Page 31
A22E A22NE-P
Common Note
Common Accessories and Tools
LED Lamps
(Example of lighting malfunction prevention circuit)
When using a 24-VAC/VDC lighted unit
• A current-limiting resistor is built in the LED lamp, so the installation of an external resistance is not required.
• Lighting malfunction of the LED lamp A micro-current of approximately 0.1 mA or less is sufficient to turn on the LED lamps. Take a countermeasure like adding a resistor to prevent mis-lighting in parallel to the LED lamp. The micro-current varies with the machine (leak current or stray capacity between cables, etc.). Select resistance value and allowable power consumption that meet the actual current.
Be sure to read the "Safety Precautions" on page 37.
LED lamp
A22NE-P
X1
R:10 kΩ (1 W) Bleeder resistor
X2
31
Page 32
A22E/A22NE-P
A22E A22NE-P
Common Note
Common Accessories and Tools
Common Accessories and Tools (Order Separately)
Ordering Information
Common to Screw Terminal Block types (A22E)/Push-in Plus Terminal Block types (A22NE-P)
Item Appearance Classification Model Remarks
60-dia. black letters on yellow back-ground
Legend Plates for Emergency Stop
Hole Plug Round A22Z-3530
Connectors
25-dia. Ring --- A22Z-R25
30-dia. Resin Attachment
Lock Ring --- A22Z-3360
90-dia. black letters on yellow back-ground
60-dia. black letters on yellow background
Applicable cable diameter
7 to 9 dia. A22Z-3500-1
9 to 11 dia. A22Z-3500-2
--- A22Z-A30
A22Z-3466-1
A22Z-3476-1
A22Z-3466-2
Used in combination with the washer rubber when the level of protection is to be met between panels.
Cannot be used in combination with the Control Boxes. Used in combination with the washer rubber when the level of protection is to be met between panels.
Used for covering the panel cutouts for future panel expansion. Black color.
Plastic connector used to extend a cable from the Switch Box. (Refer to page 27).
Use when mounting to a panel with a 25-dia. hole. (Refer to page
26). Material: Rubber, Level of protection: IP65
Use when mounting to a panel with a 30-dia. hole. (Refer to page
26). A rubber washer (A22Z-R) is provided with the product.
The body is equipped with a Lock Ring. This Lock Ring is used when a more secure lock feature is required. (Refer to page 26).
Tightening Tool --- A22Z-3905
E-stop Shroud for EMO, Yellow
E-stop Shroud for EMO, Yellow
E-stop Shroud for EMS, White
E-stop Shroud for EMS, White
E-stop Shroud, Yellow
E-stop Shroud for EMO, Yellow
Legend plate for EMERGENCY OFF is not included.
Legend plate for EMERGENCY STOP is not included.
Spacer Unit is not included. A22Z-EG2
One Spacer Unit is included. A22Z-EG21
Two Spacer Units are included.
--- A22Z-EG1
--- A22Z-EG1-W
--- A22Z-EG3
A22Z-EG10
A22Z-EG10-W
A22Z-EG22
Used for tightening the mounting ring from the back side of the panel, and for removing the cap in lighted models.
Provides SEMI-S2/SEMATECH APPLICATION GUIDE FOR SEMI-S2 compatibility. The SEMI-S2-compatible Shroud and legend plate for EMERGENCY OFF come as a set. Use with an A22E Emergency Stop Switch (for emergency shutoff) *1 *2
Provides SEMI-S2/SEMATECH APPLICATION GUIDE FOR SEMI S2 compatibility. Use with an A22E with EMO indication. (for emergency off) *2
Provides SEMI-S2/SEMATECH APPLICATION GUIDE FOR SEMI-S2 compatibility. The SEMI-S2-compatible Shroud and legend plate for EMERGENCY STOP come as a set. Use with an A22E Emergency Stop Switch. (for emergency stop) *1*2
Provides SEMI-S2/SEMATECH APPLICATION GUIDE FOR SEMI S2 compatibility. Use with an A22E with EMS indication. (for emergency stop) *2
SEMI-S2/SEMATECH APPLICATION GUIDE FOR SEMI S2-compatible Shroud. (for emergency shutoff) *1 *2 Use together with an A22E Emergency Stop Switch.
Provides SEMI-S2/SEMATECH APPLICATION GUIDE FOR SEMI-S2 compatibility. The SEMI-S2-compatible Shroud and legend plate for EMERGENCY OFF come as a set. Use with an A22E Emergency Stop Switch.(for emergency shutoff) *1 *2
Rubber Packing - A22Z-R
Used together with accessories. Contains 10 packings.
*1. These Shrouds are for use with the equipment only that conforms to SEMI standards. Do not use them for any other applications (e.g.
emergency stop switches for machines or devices such as Machine tools, Printing presses, Industrial machinery, etc).
*2.
The Control Boxes cannot be used in combination with the A22Z-3476-1 Legend Plates for Emergency Stop or the A22Z-EG@ E-stop Shrouds.
Note: 1. Accessories for A22Z-EG1: one “EMERGENCY OFF” label, two rubber packings, and one lock ring
2. Accessories for A22Z-EG10: one rubber packing and one lock ring (without label)
32
Page 33
A22E A22NE-P
Common Note
Common Accessories and Tools
Dimensions (Unit: mm)
30 dia. 1
13
2.5
6
Hole Plug Round A22Z-3530
6.1
3.8
20.5
2.8
22.2 dia.
34.7 dia.
30-dia. Resin Attachment A22Z-A30
20.5
2 1
2.8
Lock Ring A22Z-3360
22.2 dia.
30 dia.
Material: Nickel plated on iron
25-dia. Ring A22Z-R25
22 dia.
24.8 dia.
27 dia.
0.5
1.3
Material: NBR (black)
22 dia.
27 dia.
0.5
Rubber Packing A22Z-R
Screw Terminal Block Type/Push-in Plus Terminal Block Type
Legend Plates for Emergency Stop
A22Z-3476-1 (90 dia.)
A22Z-3466-1 (60 dia.)
A22E/A22NE-P
A22Z-3466-2 (60 dia.)
Black letters
Yellow
t1
Tightening Tool A22Z-3905
30 dia.
4.5
20
90 dia.
22.2 dia.
90 2
19.2 dia.
21.2 dia.
Black letters
25 dia.
Yellow
60 dia.
22.2 dia.
Black letter
Yellow
t1t1
60 dia.
22.2 dia.
33
Page 34
A22E/A22NE-P
A22E A22NE-P
Common Note
Common Accessories and Tools
2.3
+0.5
-1.5
Switch Mounting Dimension
2.3
+0.5
-1.5
Switch Mounting Dimension
Sunken section,
0.2
Switch guard
75
2.8
20.5
63
90 dia.
78 dia.
38
52.2 max.
30
40
75 min. (Determined by the height of the Switch surface in the lock position.)
22.2 dia
33 dia.
Panel Cutout Dimensions
Allowable panel thickness: 1 to 2 mm
5R
EMERGENCY OFF inscription plate (t=1)
Rubber packing (t=0.5)
Rubber packing (t=0.5)
Locking ring
Mounting panel
2
1
Panel
Switch Unit
A22E-M
2.5
+0.5
-1.5
8
R1.7
+0.1
0
22.3
+0.4
0
dia.
24.2
±0.2
“EMERGENCY STOP” is indicated on A22Z-EG1-W. Legend plate is not provided with A22Z-EG10 and A22Z-EG10-W.
8.5
38
52.2 max.
30 dia.
40 dia.
1-pole Switch Unit
2-pole Switch Unit
R5
38.5
37 max.
Panel
Panel
Screw Terminal Block type Mounting a 1-pole Switch Unit
Push-in Plus Terminal Block type Mounting a 1-pole Switch Unit
Push-in Plus Terminal Block type Mounting a 2-pole Switch Unit
Note: 1. The dimensions of the
Shroud conform to the specifications of the SEMATECH Application Guide for SEMI S2-93.
2. The Shroud is not provided with the Switch.
Common E-stop Shrouds A22Z-EG1, A22Z-EG1-W, A22Z-EG10, A22Z-EG10-W
34
Page 35
A22E A22NE-P
Common Note
Common Accessories and Tools
12
2R
M90
353
20.6
22.2 dia.
2.8
79 dia.
98 dia.
105 dia.
Detents inside (One on each side)
95
+0.2
0
5.5
+0.2
0
90.3
+0.4
0
dia.
20
23
10
13
Panel Panel
SpacersSpacer
105 max.
1b Contact Unit
Position of detent notch
Position of detent notch
Panel
The number of spacers depends on the model A22Z-EG2 : No Spacer A22Z-EG21 : 1 Spacer A22Z-EG22 : 2 Spacers
88 max.
Position of detent notch
Position of detent notch
Panel
Panel
2b One-Piece
Contact Unit
2b One-Piece
Contact Unit
72 max.
With 1 Spacer With 2 Spacers
Screw Terminal Block Type Mounting a 1-pole Switch Unit *
Screw Terminal Block Type Mounting a 2-pole Switch Unit *
Push-in Plus Terminal Block Type Mounting a 1-pole Switch Unit *
Push-in Plus Terminal Block Type Mounting a 2-pole Switch Unit *
Panel Cutout Dimensions
* These are the dimension from the front of the panel when the Switch Unit is attached.
During spacer attachment
E-stop Shrouds A22Z-EG2, A22Z-EG21, A22Z-EG22
Note: 1. The dimensions of the Shroud conform to the
specifications of the SEMATECH Application Guide for SEMI S2-93.
2. The Shroud is not provided with the Switch.
3. Tighten to a torque of 1.96 to 2.94 Nm.
4. The allowable panel thicknesses are as follows:
Without Spacers: t=1.3 to 22.5 mm With 1 Spacer: t=1.3 to 12.5 mm With 2 Spacers: t=1.3 to 2.5 mm
A22E/A22NE-P
35
Page 36
A22E/A22NE-P
A22E A22NE-P
Common Note
Common Accessories and Tools
1-pole Switch Unit
1-pole Switch Unit
2-pole Switch Unit
1.7R
+0.1
0
2.8
33 dia.
C
C
78 min. (Determined by the height of the Switch surface in the lock position.)
20.5
22.2 dia.
E-Stop Shroud
C-C
Panel
Panel
2.5
+0.5
-1.5
Portion B
Legend Plate (Provided with the Switch Guard)
Rubber Packing (t=0.5, Rubber Packing)
Panel
Locking Ring (Rubber Packing)
Mounting Nut (Provided with the Operation Unit)
Panel Cutout Dimensions
Allowable panel thickness: 1 to 3 mm
22.3 dia.
+0.4
0
Rubber Packing (t=0.5, Rubber Packing)
Portion A: Indented part
90 dia.
Switch Mounting Dimension
2.5
+0.5
-1.5
Switch Mounting Dimension
71.2 max.
C-C
38
Panel
2-pole Switch Unit
2.5
+0.5
-1.5
Switch Mounting Dimension
2.5
+0.5
-1.5
Switch Mounting Dimension
Panel
52.2 max.
38.8
52.2 max.
38
37 max.
38.8
Set model number A22Z-EG3
24.2±
0.2
Screw Terminal Block Type Mounting a 1-pole Switch Unit
Screw Terminal Block Type Mounting a 2-pole Switch Unit
Push-in Plus Terminal Block Type Mounting a 1-pole Switch Unit
Push-in Plus Terminal Block Type Mounting a 2-pole Switch Unit
E-stop Shroud A22Z-EG3
Note: 1. The dimensions of the Shroud conform to the
specifications of the SEMATECH Application Guide for SEMI S2-93.
2. The Shroud is not provided with the Switch.
36
Page 37
A22E/A22NE-P
A22E A22NE-P
Common Note
Common Accessories and Tools
Screwdriver
Hammer
Do not allow the Switch to drop and hit the floor.
Do not place or drop heavy objects on the Switch.
Do not operate the Switch with hard or sharp objects.
Safety Precautions
Be sure to read the precautions for All PushButton Switches in the website at:http://www.ia.omron.com/.
Indication and Meaning for Safe Use
Precautions
for Safe Use
Mounting
• Always make sure that the power is turned OFF before wiring the Switch. Also, do not touch the terminals or other current-carrying ports while power is being supplied. Electric shock may occur.
• Do not tighten the mounting ring more than necessary using tools such as pointed-nose pliers. Doing so will damage the mounting ring. The tightening torque is 0.98 to 1.96 N·m.
• Recommended panel thickness: 1 to 5 mm.
• When mounting the caps after changing the LED or the caps, tighten the caps at a tightening torque of 0.49 to 0.78 N·m.
Operating Environment
• The IP65 model is designed with a protective structure so that it will not sustain damage if it is subjected to water from any direction to the front of the panel.
• The Switch is intended for indoor use only. Using the Switch outdoor may cause it to fail.
Others
• If the panel is to be coated, make sure that the panel meets the specified dimensions after coating.
• Due to the structure of the Switch, severe shock or vibration may cause malfunctions or damage to the Switch. Also, most Switches are made from resin and will be damaged if they come into contact with sharp objects. Particularly scratches on the Operation Unit may create visual and operational obtrusions. Handle the Switches with care, and do not throw or drop them.
Supplementary comments on what to do or avoid doing, to use the product safely.
Precautions for Correct Use
37
Page 38
MEMO
38
Page 39
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions.
Page 40
Authorized Distributor:
In the interest of product improvement, specifications are subject to change without notice.
Cat. No. A263-E1-01
0917(0917)
© OMRON Corporation 2017 All Rights Reserved.
OMRON Corporation Industrial Automation Company
Regional Headquarters
OMRON EUROPE B.V.
Wegalaan 67-69, 2132 JD Hoofddorp The Netherlands Tel: (31)2356-81-300/Fax: (31)2356-81-388
Contact: www.ia.omron.com
Kyoto, JAPAN
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2), Alexandra Technopark, Singapore 119967 Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 200120, China Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
OMRON SCIENTIFIC TECHNOLOGIES INC.
6550 Dumbarton Circle Fremont CA 94555 U.S.A. Tel: (1) 510-608-3400/Fax: (1) 510-744-1442
Loading...