OMNIREL OMR1033ST, OMR1033SR, OMR1033NM Datasheet

OMR1033STOMR1033SR
Three T erminal, Adjustable V oltage, 3.0 Amp Precision Negative Regulators In Hermetic JEDEC TO-257AA P ackage
0 04 R1 Supersedes 0 01 R0
20 kRAD RADIATION TOLERANT 3 AMP NEGATIVE ADJUSTABLE VOLTAGE REGULATORS
FEATURES
• Available in Three Hermetic Package Styles
• Radiation Tolerant up to 30 k Rad (Si)
• Reference Voltage Set Internally to ±2%
• Built-In Thermal Ov erload Protection
• Short Circuit Current Limiting
• Product Is Available Screened To Class B and Class S, MIL-STD-883
DESCRIPTION
These three terminal negative regulators are supplied in high density hermetically sealed packages and available Hi-Rel Screened. All protective features are designed into the circuit, including thermal shutdown, current limiting and safe-area control. With heat sinking, they can deliver over 3.0 amps of output current. These units feature 2% initial voltage tolerance, with 1.0% load regulation and .015% line regulation. These devices are ideally suited for Space applications where small size, high reliability, and radiation tolerance is required. The high level of Radiation Tolerance of these devices makes them a desirable choice for LEO and many MEO and GEO communication satellites. Radiation testing is performed on a single wafer by wafer basis. Random die samples per wafer are selected, packaged and radiation tested to qualify each individual semiconductor wafer-by-wafer.
ABSOLUTE MAXIMUM RATINGS @ 25°C
Input V oltage...................................................................-35V
Operating Junction Temperature Range.............................-55°C to +150°C
Storage Temperature Range .........................................-65°to +150°C
Thermal Resistance, Junction to Case
TO-257 (Isolated), D2Pac (Isolated)...................................4.2°C/W
SMD-1................................................................3.5°C/W
Power Dissipation: TO-257/SMD/D2Pac...................................20W
OMR1033NM
OMR1033SR, OMR1033ST, OMR1033NM
ELECTRICAL CHARACTERISTICS -55°C T
A
+125°C (unless otherwise specified)
Parameter Symbol Test Conditions Min. Max. Unit
Reference V oltage V
REF
ÁVIN- V
OUT
Í = 5 V, I
OUT
= 5 mA, TA= 25° C -1.238 -1.262
V
3 V ≤ ÁV
IN
- V
OUT
Í 35 V -1.215 -1.285
Line Regulation ∆V
OUT
3 V ≤ ÁVIN- V
OUT
Í 35 V
0.015 %/V
(Note 1) ∆V
IN
0.04
Load Regulation ∆V
OUT
ÁV
OUT
Í 5 V, TA= 25° C 50
mV
(Note 1) ∆I
OUT
10 mA ≤ I
OUT
I
MAX.
75
ÁV
OUT
Í5.0 V 1.0
%
10 mA ≤ I
OUT
I
MAX.
1.5
Thermal Regulation - 30 ms pulse, T
A
= 25° C 0.02 %/W
Ripple Rejection ∆V
IN
ÁV
OUT
Í= -10 V, f = 120 Hz, C
Adj
= 0
56
dB
(Note 2) ∆V
REF
53
ÁV
OUT
Í= -10 V, f = 120 Hz, C
Adj
= 10 µF
70
dB
60
Adjust Pin Current I
Adj
V
DIFF
= 35 V, IL= 10 mA 100 µA
Adjust Pin Current Change ∆I
Adj
10 mA ≤ I
OUT
I
MAX.
2.0
µA
3 V ≤ ÁV
IN
- V
OUT
Í 35 V 5.0
Minimum Load Current I
Min
ÁVIN- V
OUT
Í 35 V 5.0
mA
ÁV
IN
- V
OUT
Í 10 V
3.0
Current Limit I
Lim
ÁVIN- V
OUT
Í 10 V
3.0 6.0 A
3.0
ÁV
IN
- V
OUT
Í = 35 V
0.5 2.5 A
0.5
Temperature Stability ∆V
OUT
-55° C ≤TJ≤ +125° C 1.5 %
(Note 2) ∆T
Long T erm Stability ∆V
OUT
TA= +125° C, t = 1000 hrs 1.0 %
(Note 2) ∆T
Notes:
1. Line and Load Regulation are measured at a constant junction temperature using a low duty cycle pulse technique. Although power dissipation is internally limited, regulation is guaranteed up to the maximum power dissipation of 30 W.
Power dissipation is determined by the input/output differential voltage and the output curren
t. Guaranteed maximum
power dissipation will not be available over the full input/output voltage range.
2. Guaranteed by design, characterization or correlation to other tested parameters.
3. The • denotes the specifications which apply over the full operating temperature range.
4. Refer to curves for typical characteristics versus total dose radiation levels.
RADIA TION TEST PROGRAM
The following chart is a summary of the test data collected on Radiation Tolerant OMR1033 at various dose rates. The chart depicts the Total Radiation Dose that each device was exposed to prior to failure. Failure is defined as any electrical test that does not meet the limits of the device per the published data sheet specifications after radiation testing.
Omnirel P/N 5K 10K 20K 30K 50K 60K 70K 80K 100K 150K 200K
Test Points X X
OMR1033SR
Loading...