Omega Products PX831 Installation Manual

Servicing USA and Canada: Call OMEGA Toll Free
OMEGA Engineering, Inc.
One Omega Drive, Box 4047
Stamford, CT 06907-0047 U.S.A.
Headquarters: (203) 359-1660
Sales: 1-800-826-6342 / 1-800-TC-OMEGA
Customer Service: 1-800-622-2378 / 1-800-622-BEST
FAX: (203) 359--7700 TELEX: 996404 EASYLINK:62968934 CABLE: OMEGA
Servicing Europe: United Kingdom Sales and Distribution Center
OMEGA Technologies Ltd.
P.O. Box 1, Broughton Astley, Leicestershire
LE9 6XR, England
Telephone: (0455) 285520 FAX: (0455) 283912
The OMEGA Complete Measurement and
Control Handbooks & Encyclopedias TM
aTemperature apH and Conductivity
aPressure, Strain & Force aData Acquisition systems aFlow and Level aElectric Heaters
PX831 and PX832
Electronic Pressure Transmitters
Call for Your FREE Handbook Set Today: (203) 359-RUSH
Operator’s Manual M3807/0502
REV A
WARRANTY
OMEGA warrants this unit to be free of defects in materials and workmanship and to give satisfactory service for a period of 13 months (PX831) or 13 months (PX832) from date of purchase. OMEGA Warranty adds an additional one (1) month grace period to the normal product warranty to cover handling and shipping time. This ensures that our customers receive maximum coverage on each product. If the unit should malfunction, it must be returned to the factory for evaluation. Our Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective it will be repaired or replaced at no charge. However, this WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of being damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA's control. Components which wear or which are damaged by misuse are not warranted. These include contact points, fuses, and triacs.
We are glad to offer suggestions on the use of our various products. Nevertheless OMEGA only warrants that the parts manufactured by it will be as specified and free of defects.
OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED.
LIMITATION OF LIABILITY: The remedies of buyer set forth herein are exclusive and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages.
Every precaution for accuracy has been taken in the preparation of this manual, however, OMEGA ENGINEERING, INC. neither assumes responsibility for any omissions or errors that may appear nor assumes liability for any damages that result from the use of the products in accordance with the information contained in the manual.
SECTION III
OPERATION
PRINCIPLE OF OPERATION
The Model PX831 and PX832 Pressure Transmitter series are designed to continuously measure process pressure. The heart of the transmitter is a silicon piezoresistive sensing chip. This miniature microetched semiconductor gives an output proportional to the applied pressure. This chip is isolated from the process media by a stainless steel diaphragm. A silicone oil or other specified fill fluid is used to transmit the process pressure to the sensor.
A surface mount amplifier board, enclosed in a sealed chamber, is used to convert the millivolt signal from the sensor to a calibrated transmitter output. Transmitter electronics are completely surge protected.
OPERATION
Each transmitter is tested over both pressure and temperature ranges. A thick film compensator circuit is used to bring the output of the sensor into specification. After compensation, every transmitter is tested a second time for pressure and temperature effects to ensure that it meets performance specifications.
RETURN REQUESTS / INQUIRIES
Direct all warranty and repair requests/inquiries to the OMEGA ENGINEERING Customer Service Department. Call toll free in the USA and-Canada: 1-800-622-2378, FAX: 203-359-781 1; International: 203359-1660, FAX: 203­359-7807.
BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, YOU MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER. FROM OUR CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence.
FOR WARRANTY RETURNS, please have the following FOR NON-WARRANTY REPAIRS OR CALIBRATION information available BEFORE contacting OMEGA: consult OMEGA for current repair/calibration charges. Have the following information avail-
1. P.O. number under which the product able BEFORE contacting OMEGA: was PURCHASED, 1. Your P.O. number to cover the COST
2. Model and serial number of the product of the repair/calibration, under warranty, and 2. Model and serial number of product,
3. Repair instructions and/or specific problems 3. Repair instructions and/or specific problems you are having with the product. you are having with the product.
OMEGA's policy is to make running changes, not model changes, whenever an improvement is possible. That way our customers get the latest in technology and engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC. (D Copyright 1992 OMEGA ENGINEERING, INC. All rights reserved including illustrations. Nothing in this manual
may be reproduced in any manner, either wholly or in part for any purpose whatsoever without written permission from OMEGA ENGINEERING, INC. Printed in U.S.A.
3-1