Omega Products PX409-001CG5V User Manual

HIGH ACCURACY TRANSDUCERS
MICRO-MACHINED SILICON COMPOUND PRESSURE RANGES
Compound Pressure Ranges mV/V, Voltage or Current Outputs
PX409 Series
Standard
U High Accuracy ±0.08% BSL Includes Linearity, Hysteresis, and Repeatability
U Broad Temperature Compensated Range
-29 to 85°C (-20 to 185°F) U Premium Temperature
Performance Span: ±0.5% Over Compensated Range
U 5-Point NIST Traceable Calibration Included
U All Stainless Steel Wetted Parts
U Fast Response Time U Solid State Reliability
and Stability U 400% Proof Pressure
Minimum
OMEGA’s PX409 Series high accuracy transducers bi-directional gage pressure range models have all stainless steel wetted parts and welded construction and premium temperature compensation which makes them suitable for use in tough industrial environments.
Compound range transducers are available in 5 ranges which measure positive and negative gage pressure and give a corresponding bi-directional outputs of ±10 mV/V, ±5 Vdc and 4 to 20 mA with ambient set at 12 mA. Ranges are available from ±10 inH2O to ±15 psi.
IP67 rated
PX409-015CGV ±15 psi range shown actual size.
Metric threads available,
see omega.com/pxconfig
Cable style.
SPECIFICATIONS
Output:
Millivolt: 0 to 10 mV/V for vacuum, ±10 mV/V for compound
Amplified Voltage: 0 to 5 Vdc for vacuum, ±5 Vdc for compound
Current Loop: 4 to 20 mA (12 mA at 0 psig on compound ranges)
Power Requirements:
Millivolt: 5 to 10 Vdc (2 mA @ 10 Vdc) Amplified Voltage:
10 to 30 Vdc @ 10 mA Current Loop: 9 to 30 Vdc
[max loop res = [(Vs-9) x 50] [9 to 20 Vdc above 105°C (229°F)]
CE Compliant: Meets industrial emission and immunity standard EN61326
Accuracy (Combined Linearity, Hysteresis and Repeatability):
±0.08% BSL max, calibrated in positive direction only, with electrical connector up
Zero Balance: ±0.5% FS typical 1% max (1% typical, 2% max for ranges 1 psi and below)
Span Setting: ±0.5% FS typical 1% max (1% typical, 2% max for ranges 1 psi and below)
Operating Temperature Range:
-45 to 121°C (-49 to 250°F) [-45 to 115°C (-49 to 240°F) for voltage or current outputs]
Compensated Temperature:
Ranges >5 psi: -29 to 85°C (-20 to 185°F)
Ranges 5 psi: -17 to 85°C (0 to 185°F)
Thermal Effects Zero (@ 0 psig Over Compensated Range):
Ranges >5 psi: ±0.5% span Ranges 5 psi: ±1.0% span
mini DIN style.
IP65 rated PX419-001CGI
±1 psi bi-directional range shown actual size.
Now Available
with M12 Connector
Thermal Effects Span (Over Compensated Range):
Ranges >5 psi: ±0.5% span Ranges 5 psi: ±1.0% span Long Term Stability (1-Year):
±0.1% FS typical Shock: 50 g, 11 mS half sine, vertical
and horizontal axis Vibration: 5-2000-5 Hz, 30 minute
cycle, Curve L, Mil-Spec 810 figure 514-2-2, vertical and horizontal axis
Response Time: <1 ms Bandwidth: DC to 1 kHz typical Proof Pressure (positive direction):
10 inH2O: 10 times full scale 1 psi: 6 times full scale
2.5 psi and Higher: 4 times full scale (Negative direction 4 times or 1 atmosphere whichever is greater)
Burst Pressure:
10 inH2O to 5 psi: 1000 psi 15 and Higher: 3000 psi
Electrical Termination:
PX409: Integral 2 m (6') cable PX419: mini DIN PX429: Twist-lock PX459: M12
Mating Connectors:
PX419: CX5302 (included) PX429: PT06F10-6S (sold separately)
Environmental Protection:
PX409: IP67 PX419, PX429 and PX459: IP65
Wetted Parts: 316 SS Pressure Port: Calibration: Comes with 5-point
calibration certificate (positive readings only for compound ranges)
Weight: 115 to 200 g (4 to 7 oz) depending upon configuration
1
-18 NPT male
4
B
B-52
Product Label
Hex 22 (0.87) AF
18 NPT
Pressure Adaptor
22
(0.88)
79 (3.1)
Conduit back end PXM409C
Integral cable back end PXM409
28
(1.1)
5
(0.2)
Twist lock back end PXM459
Vent with
porous plug
(gage units only)
mini DIN back end PXM419
5
(0.2)
M1 2x1
Ø 20.2
0.8
5
(0.2)
Vent with porous plug (gage units only)
Glass to medal sealed pins PXM449
5
PX459-015CGI
HIGH ACCURACY TRANSDUCERS COMPOUND PRESSURE RANGES
Twist-lock style.
Cable style.
All models shown
PX429-001CGV
smaller than actual size.
Metric threads available,
see omega.com/pxconfig
Custom Models Available! U Use Our Convenient On-Line
Transducer Configurator to Choose the Features You Want
U Visit omega.com/pxconfig
PX409-015CGV
Dimensions: mm (inch)
18 NPT
Pressure Adaptor
Hex 2.5 (1.0) AF
PX419-001CGI
79 (3.1)
mini DIN style.
22
(0.88)
for Details
To Order Visit omega.com/px409_comp for Pricing and Details
RANGE 2 m (6') CABLE MINI DIN TWIST-LOCK M12 CONN. psi GAGE mbar GAGE TERMINATION TERMINATION TERMINATION TERMINATION PRESSURE PRESSURE MODEL NO.* MODEL NO. MODEL NO. MODEL NO.
0 to 100 mV (@ 10 Vdc) OUTPUT
±10 inH ±1 ±69 PX409-001CGV PX419-001CGV PX429-001CGV PX459-001CGV ±2.5 ±172 PX409-2.5CGV PX419-2.5CGV PX429-2.5CGV PX459-2.5CGV ±5 ±345 PX409-005CGV PX419-005CGV PX429-005CGV PX459-005CGV ±15 ±1034 PX409-015CGV PX419-015CGV PX429-015CGV PX459-015CGV
0 to 5 Vdc OUTPUT**
±10 inH2O ±25 PX409-10WCG5V PX419-10WCG5V PX429-10WCG5V PX459-10WCG5V ±1 ±69 PX409-001CG5V PX419-001CG5V PX429-001CG5V PX459-001CG5V ±2.5 ±172 PX409-2.5CG5V PX419-2.5CG5V PX429-2.5CG5V PX459-2.5CG5V ±5 ±345 PX409-005CG5V PX419-005CG5V PX429-005CG5V PX459-005CG5V ±15 ±1034 PX409-015CG5V PX419-015CG5V PX429-015CG5V PX459-015CG5V
4 to 20 mA OUTPUT
±10 inH2O ±25 PX409-10WCGI PX419-10WCGI PX429-10WCGI PX459-10WCGI ±1 ±69 PX409-001CGI PX419-001CGI PX429-001CGI PX459-001CGI ±2.5 ±172 PX409-2.5CGI PX419-2.5CGI PX429-2.5CGI PX459-2.5CGI ±5 ±345 PX409-005CGI PX419-005CGI PX429-005CGI PX459-005CGI ±15 ±1034 PX409-015CGI PX419-015CGI PX429-015CGI PX459-015CGI
ACCESSORIES
MODEL NO DESCRIPTION
M12C-PVC-4-S-F-5 PVC cable, straight 4-pin M12 female connector one end, flying leads one end, 5 m (16.4') long, for PX459
M12C-PVC-4-R-F-5 PVC cable, right angled 4-pin M12 female connector one end, flying leads one end, 5 m (16.4') long, for PX459
Comes complete with 5-pt NIST traceable calibration.
* To order cable version with ** To order with 0 to10 Vdc output change “5V” to “10V” in model number, no extra cost. Metric threads and ranges also available,
see omega.com/pxconfig Ordering Examples: PX409-015CGV, cable termination, ±15 psig range, 10 mV/V output. PX419-001CG5V, mini DIN termination, ±1 psi range, 0 to 5 Vdc output.
O ±25 PX409-10WCGV PX419-10WCGV PX429-10WCGV PX459-10WCGV
2
1
2 NPT conduit fitting, specify model PX409C, no extra cost.
B-53