InsertIon MagnetIc FlowMeter
FMG3002-PP-D
shown smaller
than actual size.
FMG3000 Series
FMG3002
shown smaller than
actual size, with
FP-5310M fitting,
see omega.com
U For 0.5 to 12" Pipes
U No Moving Parts
U Flow-Rate Range: 0.05 to
5 m/s (0.15 to 16.4 ft/s)
U Accurate Measurement
Even in Dirty Liquids
U Multilanguage
Menu Display
U Blind 4 to 20 mA or
Frequency Output
Models With No
Display Available
U No Pressure Drop
U Corrosion-Resistant
Materials: PP or PVDF
The FMG3000 Series magmeters
are insertion-style magnetic flow
sensors with no moving parts.
All models are constructed of
corrosion-resistant materials to
provide long-term reliability with
minimal maintenance costs. When
these magmeters are used with
OMEGA’s comprehensive line of
installation fittings, sensor alignment
and insertion depth are automatic.
Fittings are required for installation.
Please refer to omega.com.
These versatile, simple-to-install
flowmeters deliver accurate flow
measurement over a wide dynamic
range in pipe sizes ranging from
0.5 to 12", satisfying the
requirements of many diverse
applications. FMG3000 Series
magmeters offer a variety of output
options for use with OMEGA flow
instrumentation that has a frequency
or 4 to 20 mA output. Flow velocity
measurement is compensated
for temperature via an integrated
temperature sensor.
SPECIFICATIONS
Performance
Linearity: ±1% rdg ±0.01 m/s (0.033 ft/s)
Repeatability: ±0.5% of rdg @ 25°C (77°F)
Minimum Conductivity: 20 µS/cm
Pipe Size Range: 0.5 to 12"
Flow Range: 0.05 to 5 m/s
(0.15 to 16.4 ft/s)
Wetted Materials
Sensor Body/Electrodes and
Grounding Ring:
PP: Polypropylene/316L SS
PVDF: PVDF/316L SS (Hastelloy
O-Rings: FPM (FKM) standard
Other Materials:
Case: PBT
Protection Rating: NEMA 4X (IP65)
Power Requirements
4 to 20 mA: 21.6 to 26.4 Vdc,
22.1 mA max
Frequency: 4.5 to 26.4 Vdc, 15 mA max,
Reverse polarity and short circuit protected
Output Specifications
Current Output (4 to 20 mA):
Loop Accuracy: 32 µA max error
(25°C @ 24 Vdc)
Isolation: Low voltage <48 Vac/Vdc
from electrodes and auxiliary power
®
)
Display (Optional):
Characters: 2 x 16
Window: Polyamide
SPDT Relay: 5 A @ 30 Vdc max,
5 A @ 250 AC max
Solid State Relay: 50 mA @ 30 Vdc,
50 mA @ 42 Vac
Maximum Cable: 300 m (1000')
Error Condition: 22.1 mA
Max Loop Resistance: 300 Ω
Frequency Output:
Max Pull-Up Voltage: 30 Vdc
Max Current Sink: 50 mA,
current limited
Maximum Cable: 300 m (1000')
Environmental Requirements
Storage Temperature: -20 to 70°C
(-4 to 158°F)
Relative Humidity: 0 to 95%
(non-condensing)
Operating Temperature:
Ambient: -10 to 70°C (14 to 158°F)
Media: 0 to 85°C (32 to 185°F)
Max Operating Pressure: 10.3 bar @
25°C (150 psi @ 77°F), 1.4 bar @ 85°C
(20 psi @ 185°F)
Standards and Approvals:
CE, NEMA 4X (IP65)
H-7
138
(5.43)
94
(3.7)
171
(6.73)
40
80
120
160
200
3
6
8
11
14
04080 120 160 200
-18 4
27
49
71 93
°F
°C
psi
bar
240
115
Pressure vs. Temperature
Media Temperature
Maximum Operating Pressure
Inlet Outlet
Flange
10 x ID 5 x ID
2 x 90° Elbow
+GF+
25 x ID 5 x ID
without
display
Dimensions: mm (inch)
Installation Guidelines
+GF+
Reducer
2 x 90° Elbow
3 dimensions
+GF+
15 x ID 5 x ID
+GF+
40 x ID 5 x ID
90° Elbow
20 x ID 5 x ID
Valve/Pump
Up- and downstream piping requirements
with display
FMG3002-PP
shown smaller
than actual size.
+GF+
+GF+
50 x ID 5 x ID
Acceptable
piping layouts
Unacceptable
piping layouts
+GF+
+GF+
+
GF
+
Vertical flow is OK IF the pipe remains
full at all times.
+
GF
+
+
GF
+
+
GF
+
To Order Visit omega.com/fmg3000_fmg3100 for Pricing and Details
Model No. (no display) Model No. (display) Wetted Materials Pipe Size (in)* Output**
FMG3001-PP FMG3001-PP-D Polypropylene/316L SS 0.5 to 4 Frequency
FMG3002-PP FMG3002-PP-D Polypropylene/316L SS 0.5 to 4 4 to 20 mA
FMG3001-PVDF FMG3002-PVDF-D PVDF/316L SS 0.5 to 4 Frequency
FMG3002-PVDF FMG3002-PVDF-D PVDF/316L SS 0.5 to 4 4 to 20 mA
FMG3101-PP FMG3101-PP-D Polypropylene/316L SS 5 to 8 Frequency
FMG3102-PP FMG3102-PP-D Polypropylene/316L SS 5 to 8 4 to 20 mA
FMG3101-PVDF FMG3101-PVDF-D PVDF/316L SS 5 to 8 Frequency
FMG3102-PVDF FMG3102-PVDF-D PVDF/316L SS 5 to 8 4 to 20 mA
FMG3201-PP FMG3201-PP-D Polypropylene/316L SS 10 to 12 Frequency
FMG3202-PP FMG3202-PP-D Polypropylene/316L SS 10 to 12 4 to 20 mA
For larger sizes consult engineering.
*
Display units also include 3 relays: 2 SPDT and 1 solid state.
**
H
Accessories
Model No. Description
FPP-1220-0021 FPM (FKM) O-ring
FPP-1224-0021 EPR (EPDM) O-ring
FPP-1228-0021 FFPM Perfluoroelastomer O-ring
CNi833
DPF701
Comes complete with operator’s manual.
For PVDF models with Hastelloy electrodes add “-HA” to the model number, consult flow engineering for price.
Ordering Examples: FMG3102-PP, polypropylene/316L SS magmeter with 4 to 20 mA output, FP-5360S, 6" PVC saddle fitting see omega.com
FMG3002-PVDF, PVDF/316L SS magmeter with 4 to 20 mA output, FMG-5310, 1" 316 SS fitting (page H-9), CNi833, controller see omega.com
1
⁄
DIN controller with relay outputs, accepts 4 to 20 mA inputs
8
1
⁄
DIN frequency input meter for rate and total
8
H-8