FMA-56[*] $575 Flowmeter with display and nylon body
FMA-57[*] 525 Flowmeter without display and nylon body
The FMA-5000 Series flowmeters
measure molecular flow—the
measurement of concern in most
applications, including chemical
processing, combustion, and
heating or cooling. No temperature
or pressure corrections are
required, unlike with most other
volumetric flow monitoring devices.
The flowmeter is operated by 2 RTD
coils around the sensor tube, which
direct a constant amount of heat
into the gas stream. The gas mass
flow carries heat from the upstream
coil to the downstream coil. The
resulting temperature difference
(T2 - T1) is detected by the RTD
coils, producing the output signal.
SPECIFICATIONS
Accuracy: 1.5% FS including
linearity over 15 to 25°C (59 to 77°F)
and 5 to 60 psia; 4% FS over 0 to 50°C
(32 to 122°F) and 1 to 150 psia
Power: 12 to 15 Vdc @ 100 mA max
Response Time: 800 ms time constant;
2 seconds typical to within ±2% of final
value over 25 to 100% FS
Temperature Coefficient:
0.08 to 15% FS/°C
Pressure Coefficient: 0.01% FS/psi
Maximum Gas Pressure: 150 psig for
nylon flow body, 500 psig for 316 SS
flow body; units are calibrated standard
for 20 psig
Gas and Ambient Temperature:
0 to 50°C (32 to 122°F)
Leak Integrity (Standard cc/s He):
1 x 10
-4
for nylon flow body;
1 x 10
-7
for 316 SS flow body
Connections:
1
⁄4 FNPT standard
Electrical Connections:
9-pin sub “D” connector
Weight: 0.91 kg (2 lb)
Code SCCM Code SLM
01
††
0 to 10 07 0 to 1
02
††
0 to 20 08 0 to 2
03 0 to 50 09 0 to 5
04 0 to 100 10 0 to 10
05 0 to 200 11 0 to 20
06 0 to 500 12 0 to 30
13 0 to 40
Flow Range†Code Table (Insert Code into Model Number)
* Insert range code to complete model number.
Note 1: To order the FMA-5000 Series with 4 to 20 mA output, add suffix “-I” to the model
number and consult Flow Engineering for price.
Note 2: To order the FMA-5600 Series with 316 SS body and 1⁄4" compression fittings,
add suffix “-ST” to part number. Consult Flow Engineering for price.
†
Flow ranges specified are for nitrogen or air. When used for other gases, a multiplication
factor is used to determine the flow rate and the digital display must be rescaled in the field.
Or request “Special Calibration” for _________gas at _________ (temperature)
and ___________ (pressure).”
††
Add $175 to price for range code “01” and “02”.
Flow Rate Plastic 316 SS
(SLM) Body Body
Up to 10 2.5 6
20 10 15
30 16 15
40 24 15
Pressure Drop
Max Pressure Drop (cm of Water)
Model No. Price Description
820-T5 $44 Power supply for FMA-5600
Accessory
Comes complete with NIST calibration certificate and operator’s manual.
Ordering Examples: FMA-5601, flowmeter with display, nylon body and 0 to 10 SCCM
range, $575 + 175 = $750.
FMA-5702, flowmeter without display or nylon body, 0 to 20 SCCM, $700.
Electronic Flowmeters
with 0 to 5 Vdc Output
AVAILABLE FOR FAST DELIVERY!