General PurPose IndustrIal aIr VelocIty/temPerature transmItter/IndIcator
FMA1000
Series
U Measures Air Velocities up to
60.9 m/sec (12,000 FPM)
U Measures Air Temperature up to
121°C (250°F)
U High Temperature Model Measures Air
Temperature up to 171°C (340°F)
U 1.5% Full Scale Accuracy (Velocity) U 0.5% Full Scale Accuracy (Temperature) U 3 Different Sensor Probe Configurations:
Fixed Probe with Top or Right Angle Back Mount, or Remote Probe with
4.5 m (15') Cable
U Hot Wire Air Velocity Sensor Design U 250 msec Response Time Programmable
up to 2 Seconds
U Economical 6 OD x 305 mm L
(1⁄4 x 12") Insertion Probe Design
U Backlit LCD Displays Air Velocity and
Air Temperature Simultaneously
U Air Velocity and Air Temperature can be
Displayed in Different Engineering Units
U Monitors Maximum and Minimum
Air Velocity and Temperature
U Dual Linear Analog Outputs for
Air Velocity and Temperature
U High and Low Velocity Alarm
Voltage Outputs
U USB PC Interface with Windows Based
PC Software
U NEMA 4 (IP65) Industrial Enclosure
The FMA1000 Series industrial air velocity/ temperature transmitter/indicator measures and displays air velocity as well as air temperature in research and development labs, HVAC applications, and other manufacturing processes. The sensor design is based on three RTD elements, one measures air temperature and the other two measures air velocity by measuring the heat loss from the RTD sensor as it cools down by the air flow. The FMA1000 series offers many standard features such as display of air velocity and temperature, two analog outputs corresponding to air velocity and temperature, high and low voltage alarm outputs, PC serial interface, and Windows® based PC interface software. The FMA1000 displays the air velocity in different engineering units such as FPM, m/sec, miles/hour, and km/hour. The air temperature is displayed in °C or °F.
Optional
D-35
6 OD x 305 mm L (1⁄4 x 12”)
sensor probe included with
4.5 m (15’) cable
Shown smaller than actual size.
FMA1000 units feature a large, easy to read, backlit LCD.
SPECIFICATIONS
Air Velocity Ranges: 0 to 500, 0 to 1000, 0 to 2000,
0 to 5000, 0 to 10,000, 0 to 12,000 FPM Air Temperature Range: -40 to 121°C (-40 to 250°F)
-40 to 171°C (-40 to 340°F) high temperature model Accuracy: Air Velocity: 1.5% full scale or 12 FPM whichever larger Air Temperature: 0.5% full scale Air Velocity/Temperature Probe: Stainless steel, 6 OD x 305 mm L (
Air Velocity/Temperature Sensor: Sensor Probe Pressure: 150 psig maximum Display: Backlit LCD, 32 x 51 mm (1.25 x 2") Response Time: 250 msec up to 2 seconds Analog Output (Air Velocity): 4 to 20 mA, 0 to 5 Vdc,
or 0 to 10 Vdc
Analog Output (Air Temperature): 0 to 5 Vdc Operating Ambient Temperature:
Sensor Probe: -40 to 121°C (-40 to 250°F)
-40 to 171°C (-40 to 340°F) high temperature model Electronic Case: 0 to 50°C (32 to 122°F) Alarms: High and low alarm voltage outputs, corresponding to air velocity
Power: 15 to 24 Vdc, 200 mA Case Dimensions: 114 H x 89 W x 33 mm D (4.5 x 3.5 x 1.3") Weight: 230 g (0.5 lb)
Refer to accessories chart on page D-36 for NIST calibration
ordering information.
1
4 OD x 12")
Three RTDs, 100 and 1000 Ω
FMA1001R-V1, with remote sensor probe and 4.5 m (15') cable, smaller than actual size.
Enlarged
view
of tip
6 mm
1
(
4
")
Fixed probe
right angle
back mount
Velocity
RTD
FMA1001B-V1,
with right angle
fixed probe, smaller
than actual size.
Power and output cable
Sensor
probe
Fixed
probe top
mount
FMA1001A-V1, with top mount fixed probe, smaller than actual size.
Power and output cable
To Order Visit omega.com/fma1000 for Pricing and Details
Model No. Range: m/sec (FPM) Description FMA1001A-*-** 0 to 5.08 (0 to 1000) FMA1002A-*-** 0 to 25.4 (0 to 5000) FMA1003A-*-** 0 to 50.8 (0 to 10,000) FMA1004A-*-** 0 to 2.54 (0 to 500) transmitter, fixed probe FMA1005A-*-** 0 to 10.16 (0 to 2000) top mount FMA1006A-*-** 0 to 60.9 (0 to 12,000) FMA1001B-*-** 0 to 5.08 (0 to 1000) FMA1002B-*-** 0 to 25.4 (0 to 5000) FMA1003B-*-** 0 to 50.8 (0 to 10,000) transmitter, fixed probe right FMA1004B-*-** 0 to 2.54 (0 to 500) angle back mount FMA1005B-*-** 0 to 10.16 (0 to 2000) FMA1006B-*-** 0 to 60.9 (0 to 12,000) FMA1001R-*-** 0 to 5.08 (0 to 1000) FMA1002R-*-** 0 to 25.4 (0 to 5000) FMA1003R-*-** 0 to 50.8 (0 to 10,000) FMA1004R-*-** 0 to 2.54 (0 to 500) transmitter, remote probe FMA1005R-*-** 0 to 10.16 (0 to 2000) FMA1006R-*-** 0 to 60.9 (0 to 12,000)
SM
OMEGACARESM extended warranty program is available for models shown on this page. Ask your sales representative for full details
Extended Warranty
Program
when placing an order. OMEGACARESM covers parts, labor and equivalent loaners.
Accessories
Model No. Description CAL-3-FLOW† NIST traceable 4-point calibration certificate TX8-100
8 conductor shielded cable, PVC insulation, 30.5 m 100' spool
FPW-15 +15 Vdc power supply PSR-24S Regulated 24 Vdc @ 400 mA power supply, screw terminal PSR-24L Regulated 24 Vdc @ 400 mA power supply, stripped leads SSLK-14-14 Compression fitting, ¹⁄₄" tube OD, ¹⁄₄ NPT T-FER-1/4 ¹⁄₄" PTFE ferrules (10 pack) for use with SSLK-14-14
compression fitting
Specify output type add suffix “-MA” for 4 to 20 mA, “-V1” for 0 to 5 Vdc, or “-V2” for
*
0 to 10 Vdc, no additional cost.
For 95 mm (3.75") short probe add suffix “-S” to model number for additional cost.
**
For high temperature probe models add suffix “HT
**
(Not offered for short probe models).
Unit is NIST traceable up to 8500 FPM.
Comes complete with 305 mm (12") long sensor probe, power/output cable, Windows based PC interface software and cable, 4-point of certificate of compliance and operator’s manual.
Ordering Examples: FMA1002A-MA, air velocity/temperature transmitter, 0 to 5000 FPM range, fixed probe top mount, 4 to 20 mA output (velocity), 0 to 5 Vdc output (temperature), and CAL-3-FLOW, NIST traceable 4-point calibration certificate.
FMA1001R-V1, air velocity/temperature transmitter, 0 to 1000 FPM range remote probe with
4.5 m (15') cable, dual voltage outputs.