Omega Products FMA1001A-MA Installation Manual

MADE IN
WITH REMOTE
FMA100XR
User’s Guide
Shop online at
®
omega.com
e-mail: info@omega.com
TOP MOUNT
FMA100XA
For latest product manuals:
BACK MOUNT
FMA100XB
omegamanual.info
FMA1000 SERIES
Air Velocity/Temperature
Transmitter and Indicator
OMEGAnet®Online Service Internet e-mail
omega.com info@omega.com
Servicing North America:
U.S.A.: Omega Engineering, Inc., One Omega Drive, P.O. Box 4047 ISO 9001 Certified Stamford, CT 06907-0047 USA
Toll Free: 1-800-826-6342 TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com
Canada: 976 Berar
Laval (Quebec), H7L 5A1, Canada Toll-Free: 1-800-826-6342 TEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca
For immediate technical or application assistance:
U.S.A. and Canada: Sales Service: 1-800-826-6342/1-800-TC-OMEGA
Customer Service: 1-800-622-2378/1-800-622-BEST Engineering Service: 1-800-872-9436/1-800-USA-WHEN
Mexico/ TEL: 001 (203) 359-1660 FAX: 001 (203) 359-7700 Latin America: e-mail: espanol@omega.com
®
®
®
Servicing Asia:
China:: 1698 Yi Shan Road, Unit 102
Min Hang District Shanghai, China 201103 Hotline: 800 819 0559/400 619 0559 e-mail: info@cn.omega.com
Servicing Europe:
Benelux: Toll-Free: 0800 099 3344 TEL: +31 20 347 21 21
FAX: +31 20 643 46 43 e-mail: sales@omegaeng.nl
Czech Republic: Frystatska 184
733 01 Karviná, Czech Republic TEL: +420-59-6311899 FAX: +420-59-6311114 e-mail: info@omegashop.cz
France: Toll-Free: 0800 541 038 TEL: 01 57 32 48 17
FAX: 01 57 32 48 18 e-mail: esales@omega.fr
Germany/ Austria: Daimlerstrasse 26
D-75392 Deckenpfronn, Germany Toll-Free: 0800 8266342 TEL: +49 (0) 7056 9398-0 FAX: +49 (0) 7056 9398-29 e-mail: info@omega.de
United Kingdom: OMEGA Engineering Ltd.
ISO 9001 Certified One Omega Drive, River Bend Technology Centre, Northbank
Irlam, Manchester M44 5BD United Kingdom Toll-Free: 0800-488-488 TEL: +44 (0) 161 777-6611 FAX: +44 (0) 161 777-6622 e-mail: sales@omega.co.uk
It is the policy of OMEGA Engineering, Inc. to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification.
The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves the right to alter specifications without notice. WARNING: These products are not designed for use in, and should not be used for, human applications.
Air Velocity/Temperature Transmitter and Indicator
Table of Contents
Section Page
Section 1 - Package Insection ............................................................................... 1-1
Included Items ................................................................................................. 1-1
Section 2 - Introduction ........................................................................................ 2-1
Introduction ..................................................................................................... 2-1
Important Considerations Before Installation .............................................2-2
Section 3 - Installation ........................................................................................... 3-1
Section 4 - Main Operations ................................................................................. 4-1
Section 5 - PC Interface and Application ........................................................... 5-1
Operation ......................................................................................................... 5-1
Maintenance ..................................................................................................... 5-4
Calibration ........................................................................................................ 5-4
FMA1000 SERIES
Section 6 - Specifications ...................................................................................... 6-1
i
FMA1000 SERIES Air Velocity/Temperature Transmitter and Indicator
List of Figures
Figure Description Page
1 FMA1000 Transmitter with Fixed Probe Mount
and Right Angle Mount ......................................................................3-3
2 FMA1000 Transmitter with a Remote Sensor Probe ...................... 3-4
3 FMA1000 Transmitter General Dimensions .................................... 3-5
4 FMA1000 Transmitter Wall Mounting Holes ................................. 3-6
5 Functional Display Flow Chart ........................................................ 4-3
6 Main Window ..................................................................................... 5-2
7 Typical Data File ................................................................................. 5-3
8 Settings Menu ..................................................................................... 5-4
ii
Section 1 - Package Inspection
Remove the packing list and verify that you have received all your equipment. If you have any questions about the shipment, please call our Customer Service Department at 1-800-622-2378 or 203-359-1660. We can also be reached on the Internet at omega.com, e-mail: cservice@omega.com. When you receive the shipment, inspect the container and equipment for any signs of damage. Note any evidence of rough handling in transit. Immediately report any damage to the shipping agent.
The carrier will not honor any damage claims unless all shipping material is saved for inspection. After examining and removing contents, save packing material and carton in the event reshipment is necessary.
Included Items
The following items are supplied with the FMA1000 air velocity transmitter:
Package Inspection
NOTE:
1
• FMA1000 air velocity/temperature transmitter
• 15 feet shielded Power/Output cable with 10 pin female mating connector with 6 feet shielded USB cable with female mating connector
• Instruction Manual
• PC application program CD
The following items are optional accessories that can be ordered separately:
Model No. Description
PSR-24S Regulated +24 Vdc @ 400 mA power supply, screw
terminal
PSR-24L Regulated +24 Vdc @ 400 mA power supply, stripped
leads
SSLK-14-14 Compression Fitting, 1⁄4" tube OD, 1⁄4" NPT
T-FER-1/4
TX8-100 8 conductor shielded cable, 24 AWG, 30m long
1
4" PTFE Ferrules (10 per pack) for use with SSLK14-14
1-1
CAUTION & SAFETY INFORMATION
If the equipment is used in a manner not specified in this manual, the protection provided by the equipment may be impaired.
The installation category is one (I).
The output terminals of this product are for use with equipments (Digital meters, chart recorders, etc.) which have no accessible live parts. Such equipment should comply with all the applicable safety requirements.
Avoid contact with Hazardous live parts.
Do not operate the equipment in flammable or explosive environments.
The equipment comes with a 4.6 m (15') shielded multi-conductor power/ output cable. This cable is an ten conductor 26 AWG stranded wire cable with rating of 300 Vdc, 105ºC (221ºF) PVC insulation. It also comes with a 2m (6') shielded USB + Four conductor cable.
Power must be disconnected before making any electrical connections.
The supply voltage to the equipment should not exceed 24 Vdc.
The recommended power supply should be VDE or UL approved. Rating of 15 to 24 Vdc @ 150 mA minimum power with overload protection, current limited to 500 mA.
There is no user replaceable fuse in this product.
The FMA1000 series passed all the EMC standards (EN61326 Emissions & EN61000 immunity) under normal mode of operation using the power/output cable provided and an external DC power supply.
1-2
Section 2 - Introduction
The FMA1000 series industrial air velocity/temperature transmitter/indicator measures and displays air velocity mass flow and air temperature of clean air flows in ducts & pipes, while producing very little pressure drop in the flow stream. The FMA1000 series can be used in research & development labs, HVAC applications, and other manufacturing processes. The sensor design is based on three RTD elements, one measures the air temperature and the other two measure the air velocity. The air velocity is measured based on the heat loss from the RTD velocity sensor as it cools down by the air flow.
The FMA1000 series offers many standard features such as dual display of air velocity & temperature, two analog outputs corresponding to air velocity & temperature, high & low voltage alarm outputs for air velocity, USB PC interface with a Windows based PC interface software. The FMA1000 displays the air velocity in feet per minute (FPM), meter per second (m/s), miles per hour (MPH), and kilometer per hour (Km/h). The air temperature is displayed in ºF & ºC.
The sensor probe is 12" long as standard. The 304 Stainless steel sensor tubing is provided with inch marks for ease of insertion depths. The sensor probe comes in four different versions as follows:
Introduction
2
• Fixed probe mount
• Right angle probe mount
• Remote probe
• Fixed short probe, 3.75" Long
2-1
2
Introduction
The following table shows all the air velocity/temperature transmitter model numbers:
Model No. Velocity Range FPM (m/s) Probe Type Temperature Measurment Range
FMA1001A-* Fixed Probe -40 to 121°C (-40 to 250°F) FMA1001A-*-HT -40 to 171°C (-40 to 340°F)
FMA1001B-* 0-1000 (0-5.1) Right Angle Probe -40 to 121°C (-40 to 250°F) FMA1001B-*-HT -40 to 171°C (-40 to 340°F)
FMA1001R-* Remote Probe -40 to 121°C (-40 to 250°F) FMA1001R-*-HT -40 to 171°C (-40 to 340°F)
FMA1002A-* Fixed Probe -40 to 121°C (-40 to 250°F) FMA1002A-*-HT -40 to 171°C (-40 to 340°F)
FMA1002B-* 0-5000 (0-25.5) Right Angle Probe -40 to 121°C (-40 to 250°F) FMA1002B-*-HT -40 to 171°C (-40 to 340°F)
FMA1002R-* Remote Probe -40 to 121°C (-40 to 250°F) FMA1002R-*-HT -40 to 171°C (-40 to 340°F)
FMA1003A-* Fixed Probe -40 to 121°C (-40 to 250°F) FMA1003A-*-HT -40 to 171°C (-40 to 340°F)
FMA1003B-* 0-10,000 (0-50.8) Right Angle Probe -40 to 121°C (-40 to 250°F) FMA1003B-*-HT -40 to 171°C (-40 to 340°F)
FMA1003R-* Remote Probe -40 to 121°C (-40 to 250°F) FMA1003R-*-HT -40 to 171°C (-40 to 340°F)
FMA1004A-* Fixed Probe -40 to 121°C (-40 to 250°F) FMA1004A-*-HT -40 to 171°C (-40 to 340°F)
FMA1004B-* 0-500 (0-2.54) Right Angle Probe -40 to 121°C (-40 to 250°F) FMA1004B-*-HT -40 to 171°C (-40 to 340°F)
FMA1004R-* Remote Probe -40 to 121°C (-40 to 250°F) FMA1004R-*-HT -40 to 171°C (-40 to 340°F)
FMA1005A-* Fixed Probe -40 to 121°C (-40 to 250°F) FMA1005A-*-HT -40 to 171°C (-40 to 340°F)
FMA1005B-* 0-2000 (0-10.16) Right Angle Probe -40 to 121°C (-40 to 250°F) FMA1005B-*-HT -40 to 171°C (-40 to 340°F)
FMA1005R-* Remote Probe -40 to 121°C (-40 to 250°F) FMA1005R-*-HT -40 to 171°C (-40 to 340°F)
FMA1006A-* Fixed Probe -40 to 121°C (-40 to 250°F) FMA1006A-*-HT -40 to 171°C (-40 to 340°F)
FMA1006B-* 0-12,000 (0-60.9) Right Angle Probe -40 to 121°C (-40 to 250°F) FMA1006B-*-HT -40 to 171°C (-40 to 340°F)
FMA1006R-* Remote Probe -40 to 121°C (-40 to 250°F) FMA1006R-*-HT -40 to 171°C (-40 to 340°F)
* - Specify analog output for air velocity
-MA, 4-20 mA output
-V1, 0-5 Vdc output
-V2, 0-10 Vdc output The air temperature analog output is 0-5 Vdc.
2-2
Loading...
+ 18 hidden pages