To Order
(Specify Model Number)
Input Output Output Power
Model No. Price Input Freq* Watt** VAR** Required
ac Watt/Var (Single Phase)
DRA-WVT-3-1A $445 115 Vac/5A 60 Hz 4-20 mA 4-20 mA 115 Vac
DRA-WVT-3-1B 445 230 Vac/5A 60 Hz 4-20 mA 4-20 mA 115 Vac
DRA-WVT-3-1C 445 115 Vac/5A 60 Hz 4-20 mA 4-20 mA 230 Vac
DRA-WVT-3-1D 445 230 Vac/5A 60 Hz 4-20 mA 4-20 mA 230 Vac
DRA-WVT-3-1E 445 115 Vac/5A 60 Hz 12±8 mA 12±8 mA 115 Vac
DRA-WVT-3-1F 445 230 Vac/5A 60 Hz 12±8 mA 12±8 mA 115 Vac
DRA-WVT-3-1G 445 115 Vac/5A 60 Hz 12±8 mA 12±8 mA 230 Vac
DRA-WVT-3-1H 445 230 Vac/5A 60 Hz 12±8 mA 12±8 mA 230 Vac
ac Watt/Var (3-Phase 3-Wire)
DRA-WVT-3-3A 485 115 Vac/5A 60 Hz 4-20 mA 4-20 mA 115 Vac
DRA-WVT-3-3B 485 230 Vac/5A 60 Hz 4-20 mA 4-20 mA 115 Vac
DRA-WVT-3-3C 485 115 Vac/5A 60 Hz 4-20 mA 4-20 mA 230 Vac
DRA-WVT-3-3D 485 230 Vac/5A 60 Hz 4-20 mA 4-20 mA 230 Vac
DRA-WVT-3-3E 485 115 Vac/5A 60 Hz 12±8 mA 12±8 mA 115 Vac
DRA-WVT-3-3F 485 230 Vac/5A 60 Hz 12±8 mA 12±8 mA 115 Vac
DRA-WVT-3-3G 485 115 Vac/5A 60 Hz 12±8 mA 12±8 mA 230 Vac
DRA-WVT-3-3H 485 230 Vac/5A 60 Hz 12±8 mA 12±8 mA 230 Vac
U ± 0.1% Accuracy
U Galvanically Isolated
U Two Simultaneous
Outputs for Watt
and VAR
U Single Phase & Three
Phase Models
* Consult engineering for 50 Hz and 400 Hz models.Comes with complete operator’s manual.
** Models with ±1mA or ±20mA outputs are also available. Consult engineering.
Ordering Example: DRA-WVT-3 to 3A 3-phase, 3-wire watt/VAR transducer,
115 Vac/5A 60 Hz input, 4-20 mA outputs for watt and VAR, 115 Vac power, $485.
$
445
Basic Unit
The DRA-WVT-3 Series combines
watt and VAR transducers in one
compact housing. Two
simultaneous proportional dc
current outputs are provided for
watt and VAR parameters. The
polarity of the watt output is
positive for unity power factor (PF);
polarity for the VAR output is
positive for lagging power factor.
Specifications
GENERAL
Accuracy: ±0.1% of span typical
for watt in 5-140% range
Temperature Stability:
< ±0.01%/°C
Response Time: < 200 millisecond
(10-90% of span)
Power Supply: 115 Vac -15/+25%,
230 Vac -15/+25%, 60Hz
Power Overload: withstands 1.45 x
nominal rating continuous
Input Current Consumption:
0.26 VA @ 5 Aac
Input Voltage Consumption:
0.15 VA @150 Vac, 0.3 VA
@ 300 Vac
Frequency: 60 Hz
Frequency Variation Effect:
< ±0.02%/Hz (for watt output)
Operating Ambient: 23 to 149°F
(-5 to 65°C); 5 to 95% RH,
noncondensing
Storage Temperature: -31 to
185°F (-35 to 85°C)
Enclosure: polycarbonate
Mounting: standard 35 mm DIN rail
or wall mount
Dimensions: 2.87"H x 3.94"W x
4.41"D (73 x 100 x 112 mm)
Weight: 1.3 lb (0.6 kg)
INPUTS
Connection: single phase or
3-phase, 3-wire
Power Factor: unity-to,
lead or lag, zero
Power Calibration Span: ±170 to
±10,000 watt/var
Overrange: +42% (at full accuracy)
Combined Watt/Var Transducers
DRA-WVT-3 Series
Isolation: 2 KV RMS/1 minute for
voltage and power inputs; 4 KV for
current inputs
CURRENT INPUTS
Current Span: 5 Aac
Current Overrange: +20%
(at full accuracy)
Peak Overload: 40 Aac RMS for
5 seconds every 10 minutes
VOLTAGE INPUTS
Voltage Span: 115 Vac, 230 Vac
Voltage Overrange: +20%
(at full accuracy)
Voltage Overload: 1.6 x nominal
rating continuous, 600 Vac max
OUTPUTS (WATT & VAR)
Output Configuration: unipolar or
bipolar current
Output Span: 4-20 mA, 12 ± 8 mA
Maximum Output Load: Rmax
(KOhms) = 16/Iout (mA)
Output Impedance: Z (KOhms) =
0.1 x Vo (Vdc)
Load Variation Effect: < ±0.03%
(for full change)
SM
OMEGA
CARE
Extended Warranty
Program
A/IN
A/OUT
One Omega Drive | Stamford, CT 06907 | 1-888-TC-OMEGA (1-888-826-6342) | info@omega.com
www.omega.com
UNITED KINGDOM
www. omega.co.uk
Manchester, England
0800-488-488
UNITED STATES
www.omega.com
1-800-TC-OMEGA
Stamford, CT.
CANADA
www.omega.ca
Laval(Quebec)
1-800-TC-OMEGA
GERMANY
www.omega.de
Deckenpfronn, Germany
0800-8266342
Karviná, Czech Republic
FRANCE
www.omega.fr
Guyancourt, France
088-466-342
CZECH REPUBLIC
www.omegaeng.cz
596-311-899
BENELUX
www.omega.nl
Amstelveen, NL
0800-099-33-44
More than 100,000 Products Available!
Temperature
Calibrators, Connectors, General Test and Measurement
Instruments, Glass Bulb Thermometers, Handheld Instruments
for Temperature Measurement, Ice Point References,
Indicating Labels, Crayons, Cements and Lacquers, Infrared
Temperature Measurement Instruments, Recorders Relative
Humidity Measurement Instruments, RTD Probes, Elements
and Assemblies, Temperature & Process Meters, Timers and
Counters, Temperature and Process Controllers and Power
Switching Devices, Thermistor Elements, Probes and
Assemblies,Thermocouples Thermowells and Head and Well
Assemblies, Transmitters, Wire
Flow and Level
Air Velocity Indicators, Doppler Flowmeters, Level
Measurement, Magnetic Flowmeters, Mass Flowmeters,
Pitot Tubes, Pumps, Rotameters, Turbine and Paddle Wheel
Flowmeters, Ultrasonic Flowmeters, Valves, Variable Area
Flowmeters, Vortex Shedding Flowmeters
pH and Conductivity
Conductivity Instrumentation, Dissolved Oxygen
Instrumentation, Environmental Instrumentation, pH
Electrodes and Instruments, Water and Soil Analysis
Instrumentation
Data Acquisition
Auto-Dialers and Alarm Monitoring Systems,
Communication Products and Converters, Data
Acquisition and Analysis Software, Data Loggers
Plug-in Cards, Signal Conditioners, USB, RS232, RS485
and Parallel Port Data Acquisition Systems, Wireless
Transmitters and Receivers
Pressure, Strain and Force
Displacement Transducers, Dynamic Measurement
Force Sensors, Instrumentation for Pressure and Strain
Measurements, Load Cells, Pressure Gauges, Pressure
Reference Section, Pressure Switches, Pressure Transducers,
Proximity Transducers, Regulators,
Strain Gages, Torque Transducers, Valves
Heaters
Band Heaters, Cartridge Heaters, Circulation Heaters,
Comfort Heaters, Controllers, Meters and Switching
Devices, Flexible Heaters, General Test and Measurement
Instruments, Heater Hook-up Wire, Heating Cable
Systems, Immersion Heaters, Process Air and Duct,
Heaters, Radiant Heaters, Strip Heaters, Tubular Heaters
click here to go to the omega.com home page