DIN Rail 2-Wire
Temperature Transmitters
DRA-TCI-2 Thermocouple Input Model
DRA-RTI-2 RTD Input Model
H-59
$
170
Basic Unit
U Isolated
U Linearized
U Field Rangeable
Models DRA-TCI-2 and
DRA-RTI-2 are linearized
temperature transmitters that
produce a 4-20 mA process signal
that is directly proportional to
temperature. These transmitters
have exceptionally high input to
output common mode rejection
(CMR), a high degree of filtering
that eliminates false output signals
and provides a low ripple current.
Model DRA-TCI-2 is available for
thermocouple types J, K, T, E, R, S
or B and provides exceptional
temperature linearization by
applying eight segment linearization
circuitry.
Model DRA-RTD-2 accepts
2 or 3 wire Pt-100 RTDs,
alpha = 0.00385. Both models are
field rangeable using a set of six
internal dip switches for coarse
ranging and front accessible zero
and span potentiometers for fine
adjustment. Test terminals are
provided to monitor the transmitter’s
4-20 mA output without disturbing
the actual process loop.
Specifications
COMMON SPECIFICATIONS
Output: 4 to 20 mA
Supply Voltage: 10-40 Vdc
Loop Resistance: R
max
(ohms) =
(V
supply
- 10) / 0.02
Temperature Stability: <±0.1% of
span/°C
Common Mode Rejection (CMR):
127 dB typical dc to 60 Hz
Isolation:1500 Vdc or peak ac
Response Time: 160 msec
(0 to 98%)
Test Terminals: 40 to 200 mV
represents 4-20 mA
Ambient Temperature Range:
-20 to 70°C (-4 to 158°F),
5 to 95% RH
Storage Temperature Range:
-30 to 85°C (-22 to 185°F)
Field Ranging: done by three
“zero” DIP switches, three “span”
DIP switches and two fine tuning
potentiometers
Enclosure: polycarbonate,
IP40 protection
Each unit supplied with complete owner’s manual. *Specify thermocouple type
J,K,T,E,R,S, or B.
Ordering Example: DRA-TCI-2-J DIN rail 2-wire J thermocouple input temperature
transmitter with DRN-PS-1000 power supply, $210 +150 = $360.
Type Input Range Low, Input Range High, Min Span
°F (°C) °F (°C) °F (°C)
K 32 (0) 2462 (1350) 180 (100)
J 32 (0) 1400 (760) 180 (100)
T 32 (0) 752 (400) 180 (100)
E 32 (0) 1832 (1000) 180 (100)
R 32 (0) 3092 (1700) 1170 (650)
S 32 (0) 3092 (1700) 1170 (650)
B 32 (0) 3092 (1700) 1170 (650)
Thermocouple Input Types and Ranges
Terminal Housing:
polycarbonate, IP20 protection
Mounting: 35 mm DIN rail
Dimensions: 3.23" H x 0.9"
W x 3.90" D (82 x 22.5 x 99 mm)
Weight: 4.6 oz. (130 g
Model DRA-TCI-2 Input:
Thermocouple types J, K, T,
E,R,S,B (see thermocouple input
types and ranges table)
Burnout Protection: upscale
Cold Junction Error: ±0.9°C
typical for 0 to 60°C ambient
change (±3°C for types R and S)
Accuracy (Including Linearity):
±0.08% of span for type K,
±0.1% to ±0.2% for other
thermocouple types, typical
MODEL DRA-RTI-2
Input: 2 or 3-wire Pt-100 RTD,
alpha = 0.00385
Accuracy (Including Linearity,
Hysteresis and Repeatability):
<±0.1% of span
Minimum Span: 79°F (26°C)
Input Span Range:
79 to 1490°F (26 to 810°C)
adjusted by three DIP switches
and span potentiometer
Input Zero Range:
-80 to 450°F (-62 to 232°C)
adjusted by three DIP switches
and zero potentiometer
Lead Compensation Error:
<0.1°C/20 Ohms lead resistance
Sensor Excitation: 1 mA
To Order
(Specify Model Number)
Model No. Price Description
DRA-TCI-2-(*) $210 DIN rail 2-wire thermocouple input temperature transmitter
DRA-RTI-2 170 DIN rail 2-wire RTD input temperature transmitter
DRN-PS-1000 150 Power supply, 95-240 Vac input, 24 Vdc @ 1A output
OMEGA
CARE
SM
Extended Warranty
Program
A/IN
A/OUT
One Omega Drive | Stamford, CT 06907 | 1-888-TC-OMEGA (1-888-826-6342) | info@omega.com
www.omega.com
UNITED KINGDOM
www. omega.co.uk
Manchester, England
0800-488-488
UNITED STATES
www.omega.com
1-800-TC-OMEGA
Stamford, CT.
CANADA
www.omega.ca
Laval(Quebec)
1-800-TC-OMEGA
GERMANY
www.omega.de
Deckenpfronn, Germany
0800-8266342
Karviná, Czech Republic
FRANCE
www.omega.fr
Guyancourt, France
088-466-342
CZECH REPUBLIC
www.omegaeng.cz
596-311-899
BENELUX
www.omega.nl
Amstelveen, NL
0800-099-33-44
More than 100,000 Products Available!
Temperature
Calibrators, Connectors, General Test and Measurement
Instruments, Glass Bulb Thermometers, Handheld Instruments
for Temperature Measurement, Ice Point References,
Indicating Labels, Crayons, Cements and Lacquers, Infrared
Temperature Measurement Instruments, Recorders Relative
Humidity Measurement Instruments, RTD Probes, Elements
and Assemblies, Temperature & Process Meters, Timers and
Counters, Temperature and Process Controllers and Power
Switching Devices, Thermistor Elements, Probes and
Assemblies,Thermocouples Thermowells and Head and Well
Assemblies, Transmitters, Wire
Flow and Level
Air Velocity Indicators, Doppler Flowmeters, Level
Measurement, Magnetic Flowmeters, Mass Flowmeters,
Pitot Tubes, Pumps, Rotameters, Turbine and Paddle Wheel
Flowmeters, Ultrasonic Flowmeters, Valves, Variable Area
Flowmeters, Vortex Shedding Flowmeters
pH and Conductivity
Conductivity Instrumentation, Dissolved Oxygen
Instrumentation, Environmental Instrumentation, pH
Electrodes and Instruments, Water and Soil Analysis
Instrumentation
Data Acquisition
Auto-Dialers and Alarm Monitoring Systems,
Communication Products and Converters, Data
Acquisition and Analysis Software, Data Loggers
Plug-in Cards, Signal Conditioners, USB, RS232, RS485
and Parallel Port Data Acquisition Systems, Wireless
Transmitters and Receivers
Pressure, Strain and Force
Displacement Transducers, Dynamic Measurement
Force Sensors, Instrumentation for Pressure and Strain
Measurements, Load Cells, Pressure Gauges, Pressure
Reference Section, Pressure Switches, Pressure Transducers,
Proximity Transducers, Regulators,
Strain Gages, Torque Transducers, Valves
Heaters
Band Heaters, Cartridge Heaters, Circulation Heaters,
Comfort Heaters, Controllers, Meters and Switching
Devices, Flexible Heaters, General Test and Measurement
Instruments, Heater Hook-up Wire, Heating Cable
Systems, Immersion Heaters, Process Air and Duct,
Heaters, Radiant Heaters, Strip Heaters, Tubular Heaters
click here to go to the omega.com home page