Omega Products DRA-DM-11 Installation Manual

Page 1
http://www.omega.com
e-mail: info@omega.com
Page 2
TM
®
Internet e-mail
info@omega.com
OMEGAnet
SM
http://www.omega.com
On-Line Service
omega.com
OMEGA
SERVICING NORTH AMERICA:
USA:
ISO 9001 Certified
One Omega Drive, Box 4047 Stamford, CT 06907-0047 Tel: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com
Canada:
976 Bergar Laval (Quebec) H7L 5A1 Tel: (514) 856-6928 FAX: (514) 856-6886 e-mail: canada@omega.com
FOR IMMEDIATE TECHNICAL OR APPLICATION ASSISTANCE:
USA and Canada: Sales Service: 1-800-826-6342 / 1-800-TC-OMEGASM
Mexico and Latin America: Tel: (95) 800-TC-OMEGASM FAX: (95) 203-359-7807
Customer Service: 1-800-622-2378 / 1-800-622-BESTSM Engineering Service: 1-800-872-9436 / 1-800-USA-WHENS M TELEX: 996404 EASYLINK: 62968934 CABLE: OMEGA
SERVICING EUROPE:
Benelux: Postbus 8034, 1180 LA Amstelveen, The Netherlands
Czech Republic: Ostravska 767,733 01 Karvina
France: 9, rue Denis Papin, 78190 Trappes
Germany/Austria: Daimlerstrasse 26, D-75392 Deckenpfronn, Germany
United Kingdom: 25 Swannington Road, P.O. Box 7, Omega Drive,
ISO 9002 Certified Broughton Astley, Leicestershire, Irlam, Manchester,
Tel: (31) 20 6418405 FAX: (31) 20 6434643 Toll Free in Benelux: 06 0993344 e-mail: nl@omega.com
Tel:42(69)6311899 FAX:42(69) 6311114 e-mail: czech@omega.com
Tel: (33) 130-621-400 FAX: (33) 130-699-120 Toll Free in France: 0800-4-06342 e-mail: france@omega.com
Tel: 49 (07056) 3017 FAX: 49 (07056) 8540 Toll Free in Germany: 0130 11 21 66 e-mail: germany@omega.com
LE9 6TU, England M44 5EX, England Tel: 44 (1455) 285520 Tel: 44 (161) 777-6611 FAX: 44 (1455) 283912 FAX: 44 (161) 777-6622 Toll Free in England: 0800-488-488 e-mail: uk@omega.com
It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification. The information contained in this document is believed to be correct but OMEGA Engineering, Inc. accepts no liability for any errors it contains, and reserves the right to alter specifications without notice. WARNING: These products are not designed for use in, and should not be used for, patient connected applications.
Page 3
Contents
1. GENERAL DESCRIPTION
2. MOUNTING INSTRUCTIONS
3. REPLACING FUSES
4. ASSEMBLING THE UNIT
5. DISTANCE SETTING
6. ALARM
7. CONNECTING THE DRA-DM-11 TO DRA-M-11
8. SPECIFICATIONS
1
Page 4
1. GENERAL DESCRIPTION
The DRA-DM-11 is the de-multiplexer unit of DRA-MDM-11, Mux/deMux system. The DRA-DM-11 unit receives the DRA-M-11 multiplexed current loop output, and generates 16 current loop outputs having the same magnitude and order as input to the DRA-M-11unit.
The DRA-DM-11 is equipped with an alarm feature which is displayed through a flashing LED and a dry contact for external activation. The alarm will be turned on whenever an interruption occurs in the communication leads.
Each current loop output is equipped with a LED indicator which lights only when the current loop is closed.
2. MOUNTING INSTRUCTIONS
The DRA-DM-11 is designed for standard DIN rail mounting. Place the unit on the upper part of the mounting rail with the fastening tab facing
down. Using a suitable flat screwdriver loosen the tab slightly and attach the unit to the rail. Once the tab is loosened, ensure that the unit is fastened securely in place.
3. REPLACING FUSES
To replace a blown fuse, disassemble the unit as follows:
3.1 Take off both terminal strips by removing the four screws at the edges.
Note :This action does not require disconnecting the cables connected to the strips.
3.2 Remove the front panel using a suitable flat screwdriver. Press down gently on the plastic springloaded tabs located in the slots on either side of the unit.
3.3 Disconnect the flat connectors which connect the front panel, printed circuit.
3.4 Replace the blown fuse.
WARNING: Never install a data input fuse rated more than 100mA, and a main fuse rated more than 800mA
2
Page 5
4. ASSEMBLING THE UNIT
The DRA-DM-11 unit includes two printed circuit cards designated as P.N 7052 and P.N 7053. The printed circuit cards should occupy the slots in the enclosure according to fig1.
Connect the flat cables between the printed circuit cards and the front panel. The front panel must be inserted into the grooves on both sides of the case while pressing down until a distinct "click" is heard. Assembly is completed by laying the terminal strips in place.
Note: The terminal strips are polarized and must not be placed backwards.
Figure 1
5. DISTANCE SETTING
The DRA-DM-11 scan rate depends on the distance between the multiplexer and the de-multiplexer. There are three jumper switches marked as 500,1Km,2Km on the printed circuit 7052; set the jumper to the proper distance selector.
6. ALARM
The DRA-DM-11 alerts by flashing the Alarm LED and by activating the Alarm relay, whenever there is any interruption in the communication. The interrupt can occur due to disconnection or short-circuiting of the connection wires, or due to failure of the DRA-M-11 power supply. When the failure is corrected, the Alarm flashing LED will turn off and the relay will release.
3
Page 6
7. CONNECTING THE DRA-DM-11 TO DRA-M-11
The DRA-DM-11 is connected to the DRA-M-11 by a twisted pair of leads. In a hostile environment, a shielded cable is recommended.
T o avoid ground-loop problems it is recommended to use a floating power supply and to ground, if necessary, the negative terminal of the DRA-DM-11 power supply.
Connection Diagram
Figure 2
8. SPECIFICATIONS
INPUT OUTPUTS
Accuracy (Refer to Current Input) Scan rates: 500m: 1Km: 2Km:
ALARM Contact rating
INDICATORS
SUPPLY Supply Voltage Supply Current Consumption
FUSES Main Fuse Analog Input Fuse
TEMPERATURE Operating Storage
HUMIDITY HOUSING
Box Terminals
WEIGHT DIMENSIONS
4
Multiplexed current loop 16, 0/4-20mA current loops
±0.1% typical, maximum ±0.25% of span Aprox. 1000 ch/sec.
Aprox. 500 ch/sec. Aprox. 250 ch/sec.
Dry contact (closed in an alarm) 1A at 230Vac max.
1 Yellow LED, Power-On indicator 16 Red LEDs, current output activity indicators 1 Red Alarm LED
24 ± 10% Vdc (regulated) 500mA
630mA, Fast Blow (5x20mm) 63mA, Fast Blow (5x20mm)
0 to 70
oC (32 to 158
-25 to +85 5 to 95% Relative humidity, non condensed Plastic Polycarbonate
According to IP50 DIN 40050 According to IP20 DIN 40050
0.6 Kg. (1.5 lb.) 73Hx200Wx121mmD (2.88"x7.88"4.76")
o
C (-13 to 185
o
F)
o
F)
Page 7
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA Warranty adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product. If the unit should malfunction, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of being damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA’s control. Components which wear are not warranted, including but not limited to contact points, fuses, and triacs.
OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by it will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIM ITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY / DISCLAIMER language, and additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED
RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID
PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit.
FOR WARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA:
1. P.O. number under which the product was PURCHASED,
2. Model and serial number of the product under warranty, and
3. Repair instructions and/or specific problems relative to the product.
OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering. OMEGA is a registered trademark of OMEGA ENGINEERING, INC. © Copyright 1996 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without prior written consent of OMEGA ENGINEERING, INC.
WARRANTY/DISCLAIMER
package and on any correspondence.
FOR NON-WARRANTY REPAIRS, consult OMEGA for current repair charges. Have the following information available BEFORE contacting OMEGA:
1. P.O. number to cover the COST of the repair,
2. Model and serial number of product, and
3. Repair instructions and/or specific problems relative to the product.
Page 8
Where Do I Find Everything I Need for
Process Measurement and Control?
OMEGA…Of Course!
TEMPERATURE
Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies
Wire: Thermocouple, RTD & Thermistor Calibrators & Ice Point References Recorders, Controllers & Process Monitors Infrared Pyrometers
PRESSURE, STRAIN AND FORCE
Transducers & Strain Gauges Load Cells & Pressure Gauges Displacement Transducers Instrumentation & Accessories
FLOW/LEVEL
Rotameters, Gas Mass Flowmeters & Flow Computers Air Velocity Indicators Turbine/Paddlewheel Systems Totalizers & Batch Controllers
pH/CONDUCTIVITY
pH Electrodes, Testers & Accessories Benchtop/Laboratory Meters Controllers, Calibrators, Simulators & Pumps Industrial pH & Conductivity Equipment
DATA ACQUISITION
Data Acquisition & Engineering Software Communications-Based Acquisition Systems Plug-in Cards for Apple, IBM & Compatibles Datalogging Systems Recorders, Printers & Plotters
HEATERS
Heating Cable Cartridge & Strip Heaters Immersion & Band Heaters Flexible Heaters Laboratory Heaters
ENVIRONMENTAL MONITORING AND CONTROL
Metering & Control Instrumentation Refractometers Pumps & Tubing Air, Soil & Water Monitors Industrial Water & Wastewater Treatment pH, Conductivity & Dissolved Oxygen Instruments
M2615/0197
Loading...