Omega Products DRA-ACT-SI-1 User Manual

H-65
To Order
(Specify Model Number)
Model No. Price Description
DRA-ACT-SI-1 $130 ac current, 0-1 A ac input, 0-1 mA output DRA-ACT-SI-2 130 ac current, 0-5 A ac input, 0-1 mA output DRA-ACT-SI-3 130 ac current, 0-1 A ac input, 0-20 mA output DRA-ACT-SI-4 130 ac current, 0-5 A ac input, 0-20 mA output DRA-ACT-SV-1 130 ac voltage, 0-150 Vac input, 0-1 mA output DRA-ACT-SV-2 130 ac voltage, 0-300 Vac input, 0-1 mA output DRA-ACT-SV-3 130 ac voltage, 0-150 Vac input, 0-20 mA output DRA-ACT-SV-4 130 ac voltage, 0-300 Vac input, 0-20 mA output
DIN Rail Mount AC Voltage/Current Signal Conditioners
U Self-Powered U ±0.1% Accuracy U Isolated U Low Profile Enclosure
Comes with complete operator’s manual. Ordering Example: DRA-ACT-SI-4, AC current signal conditioner, 0-5 Aac input,
0-20 mA output, $130.
$
130
Basic Unit
The DRA-ACT-SI AND DRA- ACT-SV Series are self-powered ac current and ac voltage input DIN rail mount signal conditioners that use the measured input to produce an accurate and linear output current. These signal conditioners have excellent accuracy, linearity and stability which make them unique.
The DRA-ACT-SI Series of ac current input models includes models for 0-1 Aac and 0-5 Aac inputs with a choice of either 0-1 mA or 0-20 mA output. The DRA-ACT-SV Series of ac voltage input models includes models for 0-150 Vac and 0-300 Vac inputs again with a choice of either 0-1 mA or 0-20 mA output. The output current from all of these self-powered models always starts at 0 mA since these units are powered from the measured signal. Therefore, when the ac current or voltage input is zero, the output is zero.
For complete safety, an internal transformer isolates the signal conditioner input from the output thus enabling these units to withstand large momentary inputs. The input to output isolation provides high output signal-to-noise ratio which makes these signal conditioners highly immune to ground loop signals and RFI.
Specifications
GENERAL Accuracy: ±0.1% (for 5-120% of
span) typical; ±0.15% max Linearity: < ±0.1% (for 5-120% of
span) typical; ±0.15% max
Temperature Stability: < 0.01%/°C Power Supply: self-powered from
measured input
Isolation: 4 KV RMS/1 minute Output: 0-1 mA, 0-20 mA
Output Ripple: < ± 0.1% of span Response Time: < 240 msec
(10-90%)
Frequency: 40-400 Hz Frequency Variation Effect:
< ± 0.02%/Hz
Max Output Loop Impedance:
Rmax (ohms) = 16/.02 = 800 ohms max @ 20 mA
Operating Ambient: -4 to 158°F (-20 to 70°C); 5 to 95% Rh, noncondensing
Storage Temperature: -40 to 194°F(-40 to 90°C)
Enclosure: polycarbonate Mounting: standard 35 mm DIN rail
or wall mount Dimensions: 2.87"H x 1.28"W x
4.49"D (73 x 32.5 x 114 mm)
Weight: 0.7 lb (0.3 kg)
DRA-ACT-SI SERIES (AC CURRENT INPUT)
Input: 0-1 Aac, 0-5 Aac Overrange: 6 Aac (for full accuracy) Overload: 10 Aac continuous Peak Overload: 40 Aac for 5
seconds every 10 minutes Input Power Consumption: 0.6 VA
@ 5A input Load Variation Effect: < ±0.02%
for full load change
DRA-ACT-SV (AC VOLTAGE INPUT)
Input: 0-150 Vac, 0-300 Vac Overrange: +20% of span
(for full accuracy) Overload: +40% of span
continuous Input Power Consumption: 0.9 VA
@ 300 Vac input
DRA-ACT-SI Series AC Current Input
DRA-ACT-SV Series AC Voltage Input
SM
OMEGA
CARE
Extended Warranty Program
A/IN
A/OUT
One Omega Drive | Stamford, CT 06907 | 1-888-TC-OMEGA (1-888-826-6342) | info@omega.com
EPG05
www.omega.com
UNITED KINGDOM
www. omega.co.uk
Manchester, England
0800-488-488
UNITED STATES
www.omega.com
1-800-TC-OMEGA
Stamford, CT.
CANADA
www.omega.ca
Laval(Quebec)
1-800-TC-OMEGA
GERMANY
www.omega.de
Deckenpfronn, Germany
0800-8266342
Karviná, Czech Republic
FRANCE
www.omega.fr
Guyancourt, France
088-466-342
CZECH REPUBLIC
www.omegaeng.cz
596-311-899
BENELUX
www.omega.nl
Amstelveen, NL 0800-099-33-44
More than 100,000 Products Available!
Temperature
Calibrators, Connectors, General Test and Measurement Instruments, Glass Bulb Thermometers, Handheld Instruments for Temperature Measurement, Ice Point References, Indicating Labels, Crayons, Cements and Lacquers, Infrared Temperature Measurement Instruments, Recorders Relative Humidity Measurement Instruments, RTD Probes, Elements and Assemblies, Temperature & Process Meters, Timers and Counters, Temperature and Process Controllers and Power Switching Devices, Thermistor Elements, Probes and Assemblies,Thermocouples Thermowells and Head and Well Assemblies, Transmitters, Wire
Flow and Level
Air Velocity Indicators, Doppler Flowmeters, Level Measurement, Magnetic Flowmeters, Mass Flowmeters, Pitot Tubes, Pumps, Rotameters, Turbine and Paddle Wheel Flowmeters, Ultrasonic Flowmeters, Valves, Variable Area Flowmeters, Vortex Shedding Flowmeters
pH and Conductivity
Conductivity Instrumentation, Dissolved Oxygen Instrumentation, Environmental Instrumentation, pH Electrodes and Instruments, Water and Soil Analysis Instrumentation
Data Acquisition
Auto-Dialers and Alarm Monitoring Systems, Communication Products and Converters, Data Acquisition and Analysis Software, Data Loggers Plug-in Cards, Signal Conditioners, USB, RS232, RS485 and Parallel Port Data Acquisition Systems, Wireless Transmitters and Receivers
Pressure, Strain and Force
Displacement Transducers, Dynamic Measurement Force Sensors, Instrumentation for Pressure and Strain Measurements, Load Cells, Pressure Gauges, Pressure Reference Section, Pressure Switches, Pressure Transducers, Proximity Transducers, Regulators, Strain Gages, Torque Transducers, Valves
Heaters
Band Heaters, Cartridge Heaters, Circulation Heaters, Comfort Heaters, Controllers, Meters and Switching Devices, Flexible Heaters, General Test and Measurement Instruments, Heater Hook-up Wire, Heating Cable Systems, Immersion Heaters, Process Air and Duct, Heaters, Radiant Heaters, Strip Heaters, Tubular Heaters
click here to go to the omega.com home page
Loading...