Thermocouple probes sold separately.
TTSS-18G-12 shown, $19, see page A-78.
DP18 Series
Starts at
$
167
⻬ Modular
Design
⻬ Options for Alarms,
Analog Output
or Communications
1
⻬ 3
⁄2-Digit LED
⻬ Available in Red or
Green Displays
⻬ Removable Screw-
Clamp Cable Connector
The DP18 Series offers a modular
design for easy selection and
installation of options and inputs.
Field-installable signal conditioner
cards provide the large user or OEM
the ability to stock options and
spare signal conditioner cards for
converting input types, meter
functions or repair. For customers
who need flexibility and wish to add
options to the meter as
requirements become more
demanding, the DP18’s fieldinstallable analog outputs, relays
and communications offer an
economical solution.
The DP18 series is a complete
family of panel meters with input
cards for voltage, process and
temperature measurement and
control. The voltage signal
conditioners will measure AC or DC
voltages or true RMS. Signal
conditioners for process inputs
accept low-level voltage or current
which can be scaled for engineering
units. Temperature meters will
provide accurate measurement of
thermocouples or RTD’s. Other
inputs include differential process,
load cells or potentiometers.
Combined with OMEGAs wide
selection of transducers, the DP18
Series is the single solution for
process measurement.
M-61
Available with thermocouple,
RTD, process, AC and DC voltage/current,
load cell, and ohmmeter inputs.
Panel Punches
Available, Visit
omega.com/panelpunches
Pressure transmitters
sold separately. PX305
Series shown, $310.
Visit omega.com/px305
for details.
General Specifications
Display: 31⁄2-digit, 14.2 mm (0.56") red LED
Signal Input: Single-ended
Conversion: A/D dual slope
Integration Period: 80 ms
NMRR: 50 db
Read Rate: 3/s
Warm-up: 5 minutes
Operating Temperature:
0 to 50°C (32 to 122°F)
Storage Temperature:
-40 to 80°C (-40 to 176°F)
Span Temperature Coefficient: 100 ppm
Zero Temperature Coefficient: 2.5 µV/°C
Power Consumption:
5.5 Va for AC powered models
3.5 W for DC powered models
Setpoints: Optional single or dual
setpoints for use in on/off control or as
alarms; 1 SPDT relay rated
2 A @ 250 Vac provided per setpoint
with adjustable deadband
Connections: Push-on connectors with
screw terminals
Case Material: ABS, DIN 43700, black
Panel Cutout: 44.5 H x 92.5 mm W
(1.75 x 3.64")
Weight: 300 g (10.6 oz)
Thermocouple Inputs
MOST POPULAR MODELS HIGHLIGHTED!
To Order (Specify Model Number)
Model No. PriceRangeResolutionAccuracy
DP18-JC$189-50 to 600°C1°C
DP18-KC1890 to 1250°C1°C
DP18-TC189-50 to 400°C1°C
DP18-EC1890 to 650°C1°C±0.2% rdg ±1 count
±1.5% rdg ±1 count (0 to 260°C)
DP18-SC1890 to 1750°C1°C±0.5% rdg ±1 count (260 to 970°C)
±0.1% rdg ±1 count (970 to 1750°C)
±2% rdg ±1 count (250 to 500°C)
DP18-RC189250 to 1750 °C1°C±0.5% rdg ±1 count (500 to 1000°C)
±0.2% rdg ±1 count (1000 to 1750°C)
RTD (Pt100; Alpha = 0.00385; 2- or 3-wire) Inputs
Model No.PriceRangeResolutionAccuracy
DP18-M1C$178-200 to 650°C1°C1°C ±1 count
DP18-M1F178-200 to 400°F1°F1°F ±1 count
DP18-M2178-150.0 to 199.9°C0.1°C0.4°C ±1 count
Process Signal Inputs
Input
Model No.PriceRangeImpedanceExcitationAccuracy
DP18-P1$1890 to 1V1.1 MΩ
DP18-P21890 to 5 V/1 to 5V1.1 MΩ
DP18-P31890 to 1 mA100 Ω10 to 24 Vdc,±0.15% rdg
DP18-P41890 to 5 mA/1 to 5 mA100 Ω50 mA max±1 count
DP18-P51890 to 20 mA/4 to 20 mA24.9 Ω
DP18-P61890 to 50 mA/10 to 50 mA10 Ω
DP18-P71890 to 20/0 to 200 Vdc1 MΩ
±0.5% rdg ±1 count
Potentiometer (Potentiometric Transducers)*
Model No.PriceInputExcitationAccuracySignal Conditioner
DP18-P8$2003-wire pot.5 Vdc @50 mA max
Differential Process*
Model No.PriceRangeAccuracySignal Conditioner
DP18-P9$1900 to 20 mA
All process input meters are fully scalable from -1999 to 1999 with selectable decimal point and zero and span adjustments.
*
Strain Gage/Load Cell
Load CellInput
Model No.PriceImpedanceImpedanceResolutionSensitivityAccuracyExcitation
DP18-L1$220350 Ω20 MΩ5 µV/ct10 mV
Ohm meter
Excitation
Model No.PriceRangeCurrentResolutionAccuracy
DP18-Q1$2300 to 199.9 Ω10 mA0.1 Ω
DP18-Q22300 to 1999 Ω1 mA1 Ω
DP18-Q3230
DP18-Q4230
Calibrators, Connectors, General Test and Measurement
Instruments, Glass Bulb Thermometers, Handheld Instruments
for Temperature Measurement, Ice Point References,
Indicating Labels, Crayons, Cements and Lacquers, Infrared
Temperature Measurement Instruments, Recorders Relative
Humidity Measurement Instruments, RTD Probes, Elements
and Assemblies, Temperature & Process Meters, Timers and
Counters, Temperature and Process Controllers and Power
Switching Devices, Thermistor Elements, Probes and
Assemblies,Thermocouples Thermowells and Head and Well
Assemblies, Transmitters, Wire
Flow and Level
Air Velocity Indicators, Doppler Flowmeters, Level
Measurement, Magnetic Flowmeters, Mass Flowmeters,
Pitot Tubes, Pumps, Rotameters, Turbine and Paddle Wheel
Flowmeters, Ultrasonic Flowmeters, Valves, Variable Area
Flowmeters, Vortex Shedding Flowmeters
pH and Conductivity
Conductivity Instrumentation, Dissolved Oxygen
Instrumentation, Environmental Instrumentation, pH
Electrodes and Instruments, Water and Soil Analysis
Instrumentation
Data Acquisition
Auto-Dialers and Alarm Monitoring Systems,
Communication Products and Converters, Data
Acquisition and Analysis Software, Data Loggers
Plug-in Cards, Signal Conditioners, USB, RS232, RS485
and Parallel Port Data Acquisition Systems, Wireless
Transmitters and Receivers
Band Heaters, Cartridge Heaters, Circulation Heaters,
Comfort Heaters, Controllers, Meters and Switching
Devices, Flexible Heaters, General Test and Measurement
Instruments, Heater Hook-up Wire, Heating Cable
Systems, Immersion Heaters, Process Air and Duct,
Heaters, Radiant Heaters, Strip Heaters, Tubular Heaters
click here to go to the omega.com home page
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.