Omega Products DOCN601-PM User Manual

Dissolved Oxygen Analyzer/Controller
DOCN600 Series
$
1740
Complete System
DOE-601 mounting assembly with cable, $525, shown smaller than actual size.
User-Friendly Design with
Front Panel Menu
Easy to Read, Large,
Bright LED Display
Quick and Easy to Calibrate 0 to 20 ppm and 0 to 100% Ranges Altitude Compensation Membrane Perforation Alarm 2 Control Relays with Third
Relay for High/Low Alarm
NEMA 4X Enclosure
DOE-601-SC DO sensing cartridge, $320.
DOCN600 Series dissolved oxygen analyzers/controllers are rugged and dependable.
The large, bright LED digital display is clear even in direct sunlight. Speedy calibration and simple operation make these microprocessor-based instruments suitable for a wide variety of demanding industrial and municipal applications. An intuitive step­through menu gives the user access to functions directly from the front panel. By pressing the MENU key, the operator can scroll through the menu, illuminating an LED beside the selected item and displaying the stored value. Arrow keys are used to change the value. Seldom used or set-once adjustments, such as password activation, are located on DIP switches on the back of the swing-out front panel.
The DOCN600 Series instruments accept the DOE-601 mounting assembly fitted with a DOE-601-SC sensor cartridge containing a precisely stretched permeable membrane, electrodes, and electrolyte. The inexpensive, easy-to-change cartridge is hermetically sealed. Optional mounting hardware includes submersion and “ball float” assemblies.
Calibration can be achieved with 1 of 7 techniques: in the process to a portable meter; in clean water to a portable meter; in a process sample to a lab meter; in a clean water sample to a lab meter; in a saturated process; in saturated clean water; and in air. To calibrate, press the MENU key until the CALIBRATION LED
DOCN601, $895, shown much smaller than actual size.
lights up. Use the arrow keys to set the value, determined with one of the above calibration methods. Press the ENTER key twice. The unit is now calibrated.
The DOCN600 Series provides 3 analog outputs: 4 to 20 mA, 0 to 5 Vdc, and 0 to 1 mA. The instrument can also control external devices with its 2 independent relays. An alarm relay has both high and low setpoints with a fixed deadband. When this relay is energized, the ALARM LED on the front panel illuminates to indicate an alarm condition. Factory-set for bidirectional control, both control relays can be set to control either a rising or falling process, with easily programmed RELAY ON and RELAY OFF setpoints.
A self-diagnostics program indicates any system errors or faults by turning the STATUS LED on the front panel from green to red. The operator then selects STATUS from the menu to determine the fault code. The operator’s manual indicates the source and likely remedy for the fault. When the fault is corrected, the STATUS LED will turn back to green.
DOCN600 Series instruments feature a rugged NEMA 4X fiberglass-reinforced polyester enclosure. They are ideal for heavy-duty outdoor applications, such as those involving municipal and industrial wastewater.
DO cartridge securing nut.
F-9
Our Dissolved Oxygen Instrumentation product line continues to expand, visit omega.com for new details!
For Sales & Service
U.S.A. and Canada
Specifications
omega.comomega.com
®
Accuracy:
% Saturation: ± 1% ppm: ± 0.1 Temp: ± 0.2°C
Resolution:
% Saturation: 0.1 ppm: 0.01
Temp: 0.1°C Repeatability: 0.1% of span or better Stability: 0.1% of span per 24 hours
non-cumulative
Temperature Drift:
Zero: 0.01% of span per °C
Span: 0.01% of span per °C Response Time: 20 seconds to 90% of
value upon step change at 20°C (68°F) Display: 3
1
/
2") LED display; 4 LED indicators: status,
( alarm, relay A, relay B Measuring Range: 0 to 20.00 ppm or 0 to 250% saturation of dissolved oxygen
Temperature: 0 to 40°C (32 to 104°F) Power Requirements:
DOCN602: 98 to 132 Vac, 50/60 Hz
(less than 10 VA), or 196 to 264 Vac
50/60 Hz, (less than 10 VA)
Ambient Conditions:
Temperature: -30 to 50°C (-22 to 122°F)
Humidity: 0 to 90% RH, non-condensing Control Relays:
Control Relays: 2, rated 5 A @115/
230 Vac; 5 A @ 30 Vdc, SPDT
Bidirectional Relays: Factory-preset for
bidirectional control; can be individually
field-set for rising or falling process
On/Off Setpoints: Field selectable
full scale
Fail-Safe: Normal or fail-safe operation Alarm Relay:
Number: 1 high and low alarm relay
Rating: 5 A 115/230 Vac; 5 A 30 Vdc, SPDT
Alarm High: Field selectable full scale
Alarm Low: Field selectable full scale
Deadband: Fixed at 2% of full scale
Fail-Safe: Normal or fail-safe operation
indicate status of 2 control relays and
alarm relay
Analog Outputs:
Non-Isolated: 0 to 1 mA, 100 W
maximum load
Non-Isolated: 0 to 5 Vdc, 1000 W
minimum load
Isolated: 4 to 20 mA, 800 W
maximum load Output: Isolated from the input, the ground, line power and all other outputs Range: Expand outputs can be scaled to represent any segment of the instrument scale to a minimum of 10% of full scale Output Holds: The analog outputs are automatically placed on hold when the instrument is placed in the menu mode Temperature: The 0 to 1 mA and 0 to 5V DC output can be selected to track either the dissolved oxygen level of the process or the temperature of the process
1
/
2 digit, 7-segment, 2.7 mm
Temperature Compensation:
Automatic 0 to 40°C (32 to 104°F) Diagnostics: Invalid entries identified by flashing LEDs, 2-color STATUS LED indicates system status: green, no fault; red, system fault, status menu value indicates system problem and likely solution, alarm LED turns red when alarm relay is energized, indicating high/low process value or memory loss, test display value and analog outputs can be manually set to any value for testing and diagnostic purposes
Safety and Security:
Operator: Password protected
(activated by DIP switch)
Memory: Non-volatile (EPROM) Microprocessor: Watchdog timer
monitors microprocessor, instrument automatically returns to online operation if left in menu mode for more than 10 minutes and no key is pressed
Enclosure: NEMA 4X molded fiberglass reinforced polyester enclosure with four
2.7 mm (
1
/
2") conduit holes and mounting
feet for surface mount; a NEMA 4X plug is
Sensor Specifications (DOE-601 with DOE-601-SC)
Temperature Range: 0 to 40°C
(32 to 104°F)
Wetted Materials: PVC and FEP Failure Alarm: 5 A SPDT relay closes if
membrane is punctured, LED on panel is illuminated Cable: Integral 8 m (26'); 300 m (1000') maximum distance to analyzer Dimensions: 105.4 mm L (4.15"), 48 mm dia. (1.89")
Cartridge: DOE-601-SC, hermetically sealed Mounting: 11/ Mounting Hardware:
Floatation Mounting:
DOE-600-BFMK consists of ball float, extension pipe, swivel bracket, junction box and 15.5 m (50') of interconnect cable
Submersion Mounting:
DOE-600-SMK consists of 1.2 m (4') PVC pipe, junction box and 15.2 m (50') of interconnect cable
4 NPT
provided for 1 hole
Mounting:
Standard: Surface mount Optional: Panel mount kit or
pipe mount kit
Dimensions: 176 H x 165 W x 108 mm D (6.9 x 6.5 x 4.25") Weight: 1.6 kg (3.5 lb)
Recommended Reference Book:
Advanced Reservoir Engineering,
FW-323, $125
Visit omega.com/bobi
for Additional Books
MOST POPULAR MODELS HIGHLIGHTED!
To Order (Specify Model Number)
Model No. Price Description DOCN601 $895 Dissolved oxygen controller, surface mount, 110 Vac DOCN601-PM 980 Dissolved oxygen controller, panel mount, 110 Vac DOCN601-PIPE 980 Dissolved oxygen controller, pipe mount, 110 Vac DOCN602 895 Dissolved oxygen controller, 220 Vac DOCN602-PM 980 Dissolved oxygen controller, panel mount, 220 Vac DOCN602-PIPE 980 Dissolved oxygen controller, pipe mount, 220 Vac
Accessories
Model No. Price Description DOCN600-PM $85 DOCN600 panel mounting kit DOCN600-PIPE 85 DOCN600 pipe mounting kit DOE-601 525 11⁄4 NPT mounting assembly and cable DOE-601-SC 320 Hermetically sealed sensor cartridge DOE-600-BFMK 615 Floatation mounting kit consists of ball float, extension pipe,
DOE-600-SMK 170 Submersion mounting kit consists of 1.2 m (4') PVC pipe,
Comes complete with operator’s manual. Ordering Examples: DOCN601, surface mount DO controller, DOE-601, mounting assembly and
cable, DOE-601-SC, sensor cartridge, $895 + 525 + 320 = $1740. DOCN601-PM, panel mount DO controller, DOE-601, mounting assembly and cable, DOE-601-SC,
sensor cartridge, $980 + 525 + 320 = $1825.
swivel bracket, junction box and 15 m (50') of cable
junction box and 15 m (50') of cable
Order Online
Over 100,000 Products Available!
To download information and to order Dissolved Oxygen Instrumentation products online, visit omega.com
F-10