Omega Products DMD4380 User Manual

DC TO DC ISOLATED SIGNAL CONDITIONER
FIELD RANGEABLE INPUTS AND OUTPUTS
Input: 0-10 mV to 0-130 Vdc, ±5 Vdc, ±10 Vdc, or 0-200 uA to 0-50 mAdc Output: 0-1V to 0-10 Vdc, ±5Vdc, ±10 Vdc, or 0-2 mA to 0-20 mAdc or 4-20 mA
DMD4380 Series
U Standard DIN Rail
Mounting
U Fast Setup–
Over 100 I/O Ranges
U Removable Connectors U Full 3-Way Isolation U Output Test Button U Built-In Loop Powers
for Sink/Source and I/O
U 80 to 265 Vac or 9 to 30 Vdc
Input Power Options Applications U Amplify, Convert or Scale
Process Signals U Isolate Single Ended
(Common Ground)
PLC Inputs U Interface Process Signals
with Panel Meters,
PLCs, Recorders, Data
Acquisition, DCS and
SCADA Systems
The DMD4380 accepts a dc voltage or current input and provides an optically isolated dc voltage or current output that is linear to the input. It provides filtering, amplifies, and converts the input signal to the selected dc voltage or current output that you select. The 3-way 1200V isolation eliminates ground loops, common mode voltages and greatly reduces noise pick-up.
Standard features include a 15 Vdc loop power supply and a 20 Vdc loop supply for the output. The power supplies can also be wired to sink or source which allows
DMD4380, shown smaller than actual size with standard DIN rail (sold separately).
the DMD4380 to be used with any combination of powered or unpowered mA inputs and powered or unpowered mA outputs including passive mA devices. Features such as red and green LEDs that vary in intensity to show input and output activity and an output test button help make set-up and troubleshooting fast and easy.
SPECIFICATIONS
Input Ranges: Field selectable
ranges via switch settings
Voltage: 0-10 mVdc to 0-50 Vdc Bipolar Voltage: ±50 mVdc to ±10 Vdc Current: 0-200 uAdc to 0-50 mAdc Input Impedance (Voltage): Voltage: 1 MΩ minimum Current: 50 Ω typical Voltage Burden: 1 Vdc at 20 mA Input Loop Power Supply:
15 Vdc ±10%, regulated, 25 mAdc; max ripple, less than 10 mV RMS may be selectively wired for sinking or sourcing
ACCESSORIES
C
Detail of front panel.
Output Ranges: Switch Selectable, Field Rangeable
Voltage (10 mA max):
0-1 to 0-10 Vdc Bipolar Voltage (10 mA max):
±5 to ±10 Vdc
Current: 0-2 mA to 0-25 mA Compliance, Drive @ 20 mA: 20V,
1000 Ω drive Output Offset: ±100% of span in 15% increments
Output Linearity: Better than ±0.1% of span
C-1
Output Zero and Span: Multi-turn
potentiometers to compensate for load and lead variations, ±15% of span adjustment range typical
Output Loop Power Supply: 20 Vdc nominal, regulated, 25 mAdc; max ripple, less than 10 mV RMS; may be selectively wired for sinking or sourcing
ELECTRICAL CONNECTIONS
TYPE OF INPUT DEVICE - TERMINAL + TERMINAL
Sensor of transmitter with a voltage output.
Transmitter with a mA (Current) output that provides power to the current loop. Typically a 3- or 4-wire device.
Transmitter with a mA (Current) output that is unpowered. Typically a 2-wire device. The DMD module provides the power.
set to “V” Measuring/recording device
accepts a mA (current) input 4(+20V) and the input is unpowered 3(-) switch E or passive. APD module set to “I” provides the loop power.
Measuring/recording device accepts a mA (current) input and the input is provides power to the loop power.
TYPE OF OUTPUT DEVICE
Measuring/recording device
accepts a voltage input.
3(-) switch E
4(+)
9(-) 11(+)
9(-) 11(+)
11(-) 10(+15V)
3(+)
2(-)
switch E
set to “I”
Output Ripple: <10 mV rms Function Test Button: Sets output to test
level when pressed; adjustable 0 to 100% of span via potentiometer. Factory default is approx. 50% of span
Response Time: 70 ms typical Common Mode Rejection: 120 db
minimum Isolation: 1200 Vrms minimum, 3-way
isolation, power to input, power to output and input to output
Operating Temperature Range:
-10 to 60°C (14 to 140°F) Thermal Stability: Better than ±0.02% of
span per °C Std. Power: 80 to 265 Vac, 50/60 Hz or
85 to 300 Vdc, 2 W maximum Low Voltage Option: 9 to 30 Vdc or
10 to 32 Vac Mounting: Mounts to standard 35 mm
DIN rail
Environmental Protection: IP40 Connections: Four 4-terminal removable
connectors 14 AWG max wire size Dimensions: 22.5 W x 117 H x 122 mm D
(0.89 x 4.62 x 4.81") height includes connectors
Weight: 150 g (5.3 oz)
SETUP INPUT AND OUTPUT (See manual for full selection)
Input
Output
Rotary Switches ABCDE ABCDE ABCDE ABCDE ABCDE ABCDE ABCDE ABCDE ABCDE ABCDE
0 to 1V 4B00V 5590V 0B00V 0100V 0000V 1490V 2000V 2400V 1C30V 2800V 0 to 5V 4B09V 5599V 0B09V 0109V 0009V 1499V 2009V 2409V 1C39V 2809V 1 to 5V 4B06V 5596V 0B06V 0106V 0006V 1496V 2006V 2406V 1C36V 2806V ±5V 4B04V 5594V 0B04V 0104V 0004V 1494V 2004V 2404V 1C34V 2804V 0 to 10V 4B03V 5593V 0B03V 0103V 0003V 1493V 2003V 2403V 1C33V 2803V ±10V 4B05V 5595V 0B005V 0105V 0005V 1495V 2005V 2405V 1C35V 2805V 4 to 20 mA 4B07I 5597I 0B007I 0107I 0007I 1497I 2007I 2407I 1C37I 2807I
Example: 1 to 5V input, 4 to 20 mA output: Code 1497I. Set switch “A” to 1,”B” to 4, switch “C” to 9, switch “D” to 7 and switch “E” to I.
CONNECTIONS
TERMINAL NO. SIGNAL
3 Sig. Out ­ 4 Sig. Out + 9 Sig. Input ­ 10 Loop Exc. 11 Sig. Input + 13 Power + 16 Power -
0 to 1 mA
4 to 20 mA
DMD4380 Standard voltage isolated DC to DC signal conditioner DMD4380-DC Low voltage isolated DC to DC signal conditioner
Comes complete with operator’s manual. Ordering Example: DMD4380, standard power, DC to DC isolated signal conditioner.
0 to 50 mV
To Order
MODEL NO. DESCRIPTION
0 to 100 mV
Visit omega.com/dmd4380 for Pricing and Details
0 to 500 mV
1 to 5V
0 to 5V
0 to 10V
± 10V
0 to 25V
C-2