Omega TAC80B-J, TAC80B-T, TAC80B-K Instruction Sheet

RoHS 2 Compliant
TAC80B-J, K, T
Thermocouple to Analog Converter
INSTRUCTION
SHEET
The OMEGA
®
TAC80B-J, K, T Thermocouple to Analog Converter can turn any chart recorder, analog or digital voltmeter into an accurate, wide range temperature measuring instrument. It is powered by either an internal 9 volt battery or an optional power adapter (TAC80B-AC). The TAC80B is a universal thermocouple amplifier and linearizer which provides a precision 1mV/°C or °F signal for type J, K or T thermocouples. Cold junction compen­sation is built in. Each unit is supplied with mating con­nector, standard-to-miniature connector adaptor, and 9V battery.
Remove the Packing List and verify that you have received all items. If you have any questions about the shipment, call the Customer Service Department. When you receive the shipment, inspect the container and equipment for any signs of damage. Note any evidence of rough handling in transit. Immediately report any damage to the shipping agent. NOTE: The carrier will not honor any claims unless all shipping material is saved for their examination. After examining and removing contents, save packing material in the event reshipment is necessary.
1. Connect the TAC80B to the strip chart recorder or
meter. The HI plug connects to the HI (+) receptacle and the LO plug to the LO (-) receptacle.
2. Plug the thermocouple into the SMP socket on the
TAC80B.
CAUTION: When the range switch is in the TEST position (center), full battery voltage (9V) is applied to the output. The power switch must be in the OFF position before switching from °F to °C or vice-versa (see Figure 1-1).
M1710/0109
Shop online at: omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info
GENERAL DESCRIPTION
UNPACKING
INSTALLATION
OPERATION
+ OUTPUT
°F °C
Figure 1-1. °C/°F Switch
K-B08CAT
golan
mrehT
Multimeter Use
1. For temperatures less than 200°C or 200°F, set the multimeter range to 200 mV.
2. For temperatures greater than 200°C or 200°F, set the multimeter range to 2 V.
Temperature is read directly on the multimeter in °C or °F; the TAC80B converts the mV signal into a temperature measurement displayed in °C.
Strip Chart Recorder Use
To use the TAC80B with a strip chart recorder, set the recorder span to the mV range that corresponds to the mV output at that temperature to be measured. For example, to read between 50°C and 150°C, set the range to 100 mV in the CALIBRATE mode and suppress the zero by 50 mV.
NOTE: Output is 1 mV per °C or 1 mV per °F.
SPECIFICATIONS
RANGES: Type J: -4° to 1112°F
OPERATING TEMPERATURE: 0° to 50°C
POWER: 9V alkaline INPUT CONNECTION: SMP connector, standard
OUTPUT CONNECTION: Standard banana plug
STORAGE TEMPERATURE: 14° to 122°F
OUTPUT: 1 mV per °C or °F ACCURACY: Type J: ±2.6°C, ±4.3°F
COLD JUNCTION COMPENSATION: 0.05°C/°C
DIMENSIONS: H: 2.25" (57mm) x
WEIGHT: 6 oz.
A-ot-elpuoco
C no retrev
®
(-20° to 600°C)
Type K: -4° to 1832°F
Type T: -4 to 572°F
Type K: ±3.6°C, ±6.1°F Type T: ±1.8°C, ±3.0°F
(-20° to 1000°C)
(-20° to 300°C)
to SMP adaptor supplied
or jack
(-10° to +50°C)
W: 2.4" (71mm) x D: 1" (25mm)
CALIBRATION
Equipment required: 3-1/2 or 4-1/2 digit multimeter with ±0.1% accuracy, stable voltage source, TRC III Ice Point Cell, TRP (J, K, T) Reference Probe.
Set up the equipment as shown below. Set the Function Switch to “°C” or “°F” position. Turn power on. Set voltage source and adjust potentiometers as follows.
Figure 1-2. Potentiometer Locations
TM
Set Voltage Source Adjust for Multimeter Reading
Model TAC80B-J
°C 0.000 mV P1 00.00 mV
33.102 mV P2 600.0 mV
°F 0.000 mV P4 32.00 mV
33.102 mV P3 1112.0 mV
Model TAC80B-K
°C 0.000 mV P1 00.00 mV
37.325 mV P2 900.0 mV
°F 0.000 mV P4 32.00 mV
37.325 mV P3 1652.0 mV
Model TAC80B-T
°C 0.000 mV P1 00.00 mV
14.862 mV P2 300.0 mV
°F 0.000 mV P4 32.0 mV
14.862 mV P3 572.0 mV
DIGITAL MULTIMETER
V
COM
A
Figure 1-3. Calibration Set-up
OMEGAnet®On-Line Service Internet e-ma il
om
ega.com info@omega.com
U.S.A.: Omega Engineering, Inc., One Omega Drive, P.O. Box 4047
ISO 9001 Certified Stamford, CT 06907-0047
Canada: 976 Bergar
For immediate technical or application assistance:
U.S.A. and Canada:
Mexico: En Español: 001 (203) 359-7803 FAX: (001) 203-359-7807
Benelux: Managed by the United Kingdom Office
Czech Republic: Frystatska 184
France:
Germany/Austria: Daimlerstrasse 26
United Kingdom: OMEGA Engineering Ltd.
ISO 9001 Certified One Omega Drive, River Bend Technology Centre, Northbank
It is the policy of OMEGA Engineering, Inc. to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the mark to every appropriate device upon certification.
The information contained in this document is believed to be correct, but OMEGA Engineering, Inc. accepts no liability for any errors it contains, and reserves the right to alter specifications without notice. WARNING: These products are not designed for use in, and should not be used for, human applications.
Servicing North America:
Tel: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com
Laval (Quebec), Canada H7L 5A1 Toll-Free: 1-800-826-6342 TEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca
Sales Service: 1-800-826-6342/1-800-TC-OMEGA Customer Service: 1-800-622-2378/1-800-622-BEST Engineering Service: 1-800-872-9436/1-800-USA-WHEN
info@omega.com.mx e-mail: espanol@omega.com
®
®
®
Servicing Europe:
Toll-Free: 0800 099 3344 TEL: +31 20 347 21 21 FAX: +31 20 643 46 43 e-mail: sales@omega.nl
733 01 Karviná, Czech Republic Toll-Free: 0800-1-66342 TEL: +420-59-6311899 FAX: +420-59-6311114 e-mail: info@omegashop.cz
Managed by the United Kingdom Office Toll-Free: 0800 466 342 TEL: +33 (0) 161 37 29 00 FAX: +33 (0) 130 57 54 27 e-mail: sales@omega.fr
D-75392 Deckenpfronn, Germany Toll-Free: 0 800 6397678 TEL: +49 (0) 7059 9398-0 FAX: +49 (0) 7056 9398-29 e-mail: info@omega.de
Irlam, Manchester M44 5BD England Toll-Free: 0800-488-488 TEL: +44 (0)161 777-6611 FAX: +44 (0)161 777-6622 e-mail: sales@omega.co.uk
K TYPE
THERMOCOUPLE LEADS
COM
V
+
INPUT
K TYPE
THERMOCOUPLE CONNECTOR
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of pu rchase. OMEGA’s WARRAN TY adds an additiona l one (1) mo nth grace p eriod to t he normal one (1) year prod uct warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product.
If the unit malfunctions, it must be re turned to the factory for evaluation. OMEGA’s Customer Service Department will i ssue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, i ncluding but not limited to mishandling, improper interfacin g, o peration outside of design limit s, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of hav ing been dam aged as a re sult of exc essi ve c orrosi on; or c urr ent, hea t, m oistur e or vib ration ; impro per spec ificat ion; misapplication; m isuse or other operating conditions out side of OMEGA’s control . C omponents in which wear is not warranted, include but are not limited to contact points, fuses, and triacs.
OMEGA is pleased to o ffer suggest ions on the use of its variou s prod ucts. However, OMEGA neither assumes respons ibility for any omissions or er rors nor a ssumes liability for any damages that result from t he use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by the company will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLI ED, EXCEPT THAT OF TITLE, AND ALL IMPLIE D WARRA NTIES INCLUD ING ANY WARRANT Y OF MERCHANTABI LITY AND FITNE SS FOR A PARTICULA R PURPOSE ARE HEREBY DISCLAIM ED. LIMITATION OF LI ABILITY: The remedies of pu rchaser set forth herein are excl usiv e, and the total liab ilit y of OMEGA with respec t to this order, whethe r bas ed on c ontr act, warr anty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY/ DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.
Direc t all warranty and repai r request s/inqu iries to t he OMEGA C ustome r Service D epartme nt. BEFORE RETURNING ANY
PRODUCT( S) TO OMEGA, P URCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORD ER TO AVOID P ROCESSING DELAYS). T he assigned AR num ber should then b e m arked on the outside of the return package and on any correspondence. The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit.
FOR WARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA:
. Purchase Order number under which the product was
1
2. Model and serial number of the product under warranty, and
3. Repair instructions and/or specific problems relative to the
OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the lat­est in technology and engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC.
Copyright 2009 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced
© to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.
PURCHASED,
product.
COPPER CONNECTOR
TRC III
COPPER LEADS
0 0 4 0 9 5
100mV 10mV 1mV 100µV 10µV
STABLE VOLTAGE SOURCE
SERIES TRP REFERENCE PROBES
ICE POINT GENERATOR
WARRANTY/ DISCLAIMER
RETURN REQUESTS / INQUIRIES
FOR NON-WARRANTY REPAIRS, charges. Have the following information available BEFORE
ontacting OMEGA:
c
. PurchaseOrder number to cover the COST of the repair,
1 2
3. Repair instructions and/or specific problems relative to the
d serial number of the product, and
. Model an
product.
1µV
consult OMEGA for current repair
Loading...