ISO 9001 Certified River Bend Technology Centre, Northbank
Irlam, Manchester M44 5BD England
Toll-Free: 0800-488-488TEL: +44 (0)161 777-6611
FAX: +44 (0)161 777-6622e-mail: sales@omega.co.uk
OMEGAnet®On-Line Service Internet e-mail
omega.com info@omega.com
It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI
regulations that apply. OMEGA is constantly pursuing certification of its
products to the European New Approach Directives. OMEGA will add the CE
mark to every appropriate device upon certification.
The information contained in this document is believed to be correct, but
OMEGA Engineering, Inc. accepts no liability for any errors it contains, and
reserves the right to alter specifications without notice.
WARNING: These products are not designed for use in, and should not be
used for, human applications.
Thank you for purchasing model HH147,
RS232 Data Logger Thermometer. Please take
a few minutes to browse through this user
manual before you begin to operate the unit to
ensure that you are fully familiarized on how
to best operate the meter.
The model HH147 features a microprocessorrated digital temperature gauge.
2. Polarity indicator: No indicator is shown when
readouts are in the positive value while the
symbol “-” is prompted when readouts fall into
the negative value.
3. Overload indicator: “OL” or “-OL” is displayed.
4. Low battery indicator: The symbol “ ” is
prompted on the LCD when the battery runs
low.
5. Power source: Four AAA batteries.
6. Auto power off: The unit powers down after
20 minutes of operation. Press the “Shift”
key for 3 seconds, the auto power off will be
disabled.
7. Sample rate: 1 time/sec.
8. Battery life: Approx. 550 hours.
9. Operating Temperature and Humidity:
0°~50°C (32°~122°F), 0~80%RH
3. Accuracy: The basic accuracy does not include
the error of the thermocouple.
K/J/T/E/-type:
±(0.1% reading +0.7°C) -100°~-1300°C
±(0.1% reading +1.4°F) -148°~2372°F
R/S-type:
±(0.1% reading +2°C) 0°~1700°C
±(0.1% reading +4°F) 32°~3092°F
N-type:
±(0.1% reading +1.5°C) 100°~1300°C
±(0.1% reading +3°F) 148°~2372°F
4. Resolution:
1°C
-100°~1300°C-100°~200°C
K
-100°~1000°C-100°~150°C
J
-100°~400°C-100°~150°C
T
E
R
S
N
-50°~800°C
0°~1700°C
0°~1700°C
-100°~1300°C
4
0.1°C
-50°~100°C
-100°~150°C
5
Operation
1. : Power ON/OFF Key.
Press the power button to turn the power
ON or OFF.
2. °C/°F/K: The Temp. Unit Selection Key.
Press the key to sequentially alternate
the three temp. units of °C, °F, and K.
3. HOLD: The Readout Hold Function Key.
Press the “HOLD” key, a “HOLD” icon
will display on the LCD and the readout
will be held in; press the “HOLD” key
once more to cancel the “HOLD”
function.
4. MAX/MIN/Avg: The Maximum/Minimum/
Average Readout Function Key
6
Operation
5. REL: The Minus Relative Readout Function Key.
Press the “REL” key, a “REL” icon will
display on the LCD and the original temp.
will go to 0 and save the original temp.
to make a standard value.
Whenever the input temp. shifts, the LCD
will show the minus value of the original
temp. value and input temp. value.
6.1°: 1° or 0.1° Unit Selection Function Key
Press the “1” key, the whole resolution will
become 1°C.1°F, and eliminate the dot. Press
the key again and the display will be restored
to the common state (the resolution will
become 0.1°C/0.1°F).
Note: The resolution of the thermocouple types
is shown on page 4.
7
Operation
8
Operation
8. TYPE: Select a thermocouple type function key.
HH147 includes seven diffferent
thermocouple types. The method of
operation:
9