M-3549/1299(HH303) 1/23/00 7:55 PM Page 2
Where Do I Find Everything I Need for Process Measurement and Control?
OMEGA…Of Course!
TEMPERATURE
Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies
Wire: Thermocouple, RTD & ThermistorCalibrators & Ice Point References
Recorders, Controllers & Process MonitorsInfrared Pyrometers
PRESSURE, STRAIN AND FORCE
Transducers & Strain GagesLoad Cells & Pressure GagesDisplacement Transducers
Instrumentation & Accessories
FLOW/LEVEL
Rotameters, Gas Mass Flowmeters & Flow Computers
Air Velocity Indicators
Turbine/Paddlewheel SystemsTotalizers & Batch Controllers
pH/CONDUCTIVITY
pH Electrodes, Testers & AccessoriesBenchtop/Laboratory Meters
Controllers, Calibrators, Simulators & PumpsIndustrial pH & Conductivity Equipment
DATA ACQUISITION
Data Acquisition & Engineering SoftwareCommunications-Based Acquisition SystemsPlug-in Cards for Apple, IBM & CompatiblesDatalogging Systems
Recorders, Printers & Plotters
HEATERS
Heating Cable
Cartridge & Strip HeatersImmersion & Band HeatersFlexible Heaters
Laboratory Heaters
ENVIRONMENTAL MONITORING AND CONTROL
Metering & Control InstrumentationRefractometers
Pumps & Tubing
Air, Soil & Water Monitors
Industrial Water & Wastewater Treatment
pH, Conductivity & Dissolved Oxygen Instruments
User’sGuide
omega.comTM
®
www.omega.com e-mail: info@omega.com
OMEGANETTE®
HH303
M3549/1299 |
Type K J Thermometer |
|
M-3549/1299(HH303) 1/23/00 7:55 PM Page 4
omega.comTM
|
|
® |
|
|
|
|
|
|
|
|
|
|
OMEGAnet® On-Line Service |
|
Internet e-mail |
|
|
|
|
www.omega.com |
|
info@omega.com |
|
|
|
Servicing North America: |
|||
USA: |
One Omega Drive, Box 4047 |
|
|
||
ISO 9001 Certified |
Stamford CT 06907-0047 |
|
|
||
|
|
Tel: (203) 359-1660 |
FAX: (203) 359-7700 |
||
|
|
e-mail: info@omega.com |
|
|
|
Canada: |
976 Bergar |
|
|
||
|
|
Laval (Quebec) H7L 5A1 |
|
|
|
|
|
Tel: (514) 856-6928 |
FAX: (514) 856-6886 |
||
|
|
e-mail: info@omega.ca |
|
|
|
For immediate technical or application assistance: |
|||||
USA and Canada: |
Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA® |
||||
|
|
Customer Service: 1-800-622-2378 / 1-800-622-BEST® |
|||
|
|
Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN® |
|||
|
|
TELEX: 996404 EASYLINK: 62968934 |
CABLE: OMEGA |
||
Mexico: |
Tel: (001) 800-826-6342 |
FAX: (001) 203-359-7807 |
|||
|
|
En Espan˜ol: (001) 203-359-7803 |
e-mail: espanol@omega.com |
||
|
|
|
|
info@omega.com.mx |
|
|
|
Servicing Europe: |
|
|
|
Benelux: |
Postbus 8034, 1180 LA Amstelveen, The Netherlands |
||||
|
|
Tel: +31 (0)20 6418405 |
FAX: +31 (0)20 6434643 |
||
|
|
Toll Free in Benelux: 0800 0993344 |
|
|
|
|
|
e-mail: nl@omega.com |
|
|
|
Czech Republic: |
Rudé armády 1868, 733 01 Karviná 8 |
|
|
||
|
|
Tel: +420 (0)69 6311899 |
FAX: +420 (0)69 6311114 |
||
|
|
Toll Free: 0800-1-66342 |
e-mail: czech@omega.com |
||
France: |
9, rue Denis Papin, 78190 Trappes |
|
|
||
|
|
Tel: +33 (0)130 621 400 |
FAX: +33 (0)130 699 120 |
||
|
|
Toll Free in France: 0800-4-06342 |
|
|
|
|
|
e-mail: france@omega.com |
|
|
Germany/Austria: Daimlerstrasse 26, D-75392 Deckenpfronn, Germany
|
Tel:+ 49 (0)7056 3017 |
FAX: +49 (0)7056 8540 |
|
Toll Free in Germany: 0800 TC-OMEGASM |
|
|
e-mail: germany@omega.com |
|
United Kingdom: One Omega Drive, River Bend Technology Centre |
||
ISO 9002 Certified |
Northbank, Irlam, Manchester |
|
|
M44 5EX United Kingdom |
|
|
Tel: +44 (0)161 777 6611 |
FAX: +44 (0)161 777 6622 |
|
Toll Free in United Kingdom: 0800-488-488 |
|
|
e-mail: sales@omega.co.uk |
|
It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification.
WARRANTY/DISCLAIMER
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product.
If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA’s control. Components which wear are not warranted, including but not limited to contact points, fuses, and triacs.
OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by it will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESS OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY / DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.
RETURN REQUESTS / INQUIRIES
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit.
FOR WARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA:
1.Purchase Order number under which the product was PURCHASED,
2.Model and serial number of the product under warranty, and
3.Repair instructions and/or specific problems relative to the product.
FOR NON-WARRANTY REPAIRS, consult OMEGA for current repair charges. Have the following information available BEFORE contacting OMEGA:
1.Purchase Order number to cover the COST of the repair,
2.Model and serial number of the product, and
3.Repair instructions and/or specific problems relative to the product.
OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC.
© Copyright 1999 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.
The information contained in this document is believed to be correct, but OMEGA Engineering, Inc. accepts no liability for any errors it contains, and reserves the right to alter specifications without notice.
WARNING: These products are not designed for use in, and should not be used for, patient-connected applications.
Type K J Thermometer
C O N T E N T S
I.Introduction
II. Specifications
III. Symbol Definition and Button
Location
IV. Operation Instructions
! " #$
% & & !
' ($) * !
+ MAX/MIN/AVG $) * ! + ,- $))+
. / 0 # +
!$ ,
Type K J Thermometer
I. Introduction:
This instrument is a digital thermometer for use with any K-type and J-type thermocouple as temperature sensor.
Temperature indication follows National Bureau of Standards and IEC584 temperature/voltage table for K-type and J-type thermocouples.
II.Specifications:
Numerical Display:
4 digital liquid crystal display
Measurement Range: |
|
|
|
|
||
K-Type: |
-200°C ~ 1370°C |
-328°F ~ 2498°F |
|
|
||
J-Type: |
-200°C ~ 760°C |
-328°F ~ 1400°F |
|
|
||
Resolution: |
|
|
|
|
|
|
K-Type: |
-200°C~ 800°C |
0.1°C; |
800°C ~1370°C |
1°C |
||
J-Type: |
-328°F~ 1000°F 0.1°F; else 1°F |
|
|
|||
-200°C~ 600°C |
0.1°C; |
600°C ~760°C |
1°C |
|||
|
-328°F~ 1000°F 0.1°F; else |
1°F |
|
|
||
Maximum Voltage at Thermocouple Input: |
|
|
||||
60V DC, or 24Vrms AC |
|
|
|
|
||
Environmental: |
|
|
|
|
||
ο Operating Temperature and Humidity: |
|
|
||||
0°C ~50°C (32°F ~ 122°F) ; 0 ~ 80% RH |
|
|
||||
ο Storage Temperature and Humidity: |
|
|
|
|||
-10°C to 60°C (14°F ~ 140°F); 0 ~ 80% RH |
|
|
||||
ο Altitude up to 2000 meters. |
|
|
|
|
||
Accuracy: |
at ( 23 ± 5°C ) |
|
|
|
|
|
|
|
|
|
|
|
|
|
Range |
|
|
Accuracy |
|
|
K-Type -200°C ~ 1370°C |
|
±(0.1% reading + 0.7°C) |
|
|
||
J-Type -2000°C ~ 760°C |
|
±(0.1% reading + 0.7°C) |
|
|
||
K-Type -328°F ~ 2498°F |
|
±(0.1% reading + 1.4°F) |
|
|
||
J-Type -328°F ~ 1400°F |
|
±(0.1% reading + 1.4°F) |
|
|
For T1-T2 Measurement, the accuracy is ±( 0.2% T1-T2 reading + 1.7°C) or ±( 0.2% T1-T2 reading + 3.4°F)
Type K J Thermometer
Temperature Coefficient:
For ambient temperatures from 0°C ~ 18°C and 28°C ~ 50°C, for each °C ambient below 18°C or above 28°C add the following tolerance into the accuracy spec.
0.01% of reading + 0.03°C ( 0.01% of reading + 0.06°F )
Note:
The basic accuracy Specification does not include the error of the probe please refer to the probe accuracy specification for additional details.
Sample Rate: 2.5 times per second
Dimension: 184 64 30mm
Weight: 210g Approx.(7.4oz)
Accessory:
K Type Bead Probe, Battery, Carrying Case, Instruction Menu.
Option:
Soft Ware Package ( Program, RS232 Connection Cable) , AC Adapter.
Power requirement:
9 Volt Battery, NEDA 1604 or JIS 006P or IEC6F22
Battery Life:
Approx. 100hrs with alkaline battery
AC Adapter:
9VDC ±15% 100mA ; Plug Diameter: 3.5 1.35mm