Omega DRN-PS-1000 User Manual

http://www.omega.com
e-mail: info@omega.com
®
UserÕs Guide
DRN-PS-1000
UNIVERSAL SWITCHING POWER SUPPLY
Compact DIN-Rail 24 Volt
MADE
IN
Servicing North America:
USA:
One Omega Drive, P.O. Box 4047
ISO 9001 Certified
Stamford, CT 06907-0047 TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com
Canada: 976 Bergar
Laval (Quebec) H7L 5A1 TEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca
For immediate technical or application assistance:
USA and Canada:
Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA
¨
Customer Service: 1-800-622-2378 / 1-800-622-BEST
¨
Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN
¨
TELEX: 996404 EASYLINK: 62968934 CABLE: OMEGA
Mexico TEL: (001)800-TC-OMEGA
SM
FAX: (001) 203-359-7807
En Espa–ol: (001) 203-359-7803 e-mail: info@omega.com.mx
Servicing Europe:
Benelux:
Postbus 8034, 1180 LA Amstelveen, The Netherlands TEL: +31 (0)20 6418405 FAX: +31 (0)20 6434643 Toll Free in Benelux: 0800 0993344 e-mail: nl@omega.com
Czech Republic: RudŽ arm‡dy 1868, 733 01 Karvin‡ 8
TEL: +420 (0)69 6311899 FAX: +420 (0)69 6311114 e-mail: czech@omega.com
France: 9, rue Denis Papin, 78190 Trappes
TEL: +33 (0)130 621 400 FAX: +33 (0)130 699 120 Toll Free in France: 0800406342 e-mail: france@omega.com
Germany/Austria: Daimlerstrasse 26, D-75392 Deckenpfronn, Germany
TEL: +49 (0)7056 9398-0 FAX: +49 (0)7056 9398-29 Toll Free in Germany: 0800 TC-OMEGA
SM
e-mail: germany@omega.com
United Kingdom: One Omega Drive
ISO 9002 Certified River Bend Technology Centre
Northbank, Irlam Manchester M44 5EX United Kingdom TEL: +44 (0)161 777 6611 FAX: +44 (0)161 777 6622 Toll Free in the UK: 0800 488 488 e-mail: sales@omega.co.uk
OMEGAnet
SM
On-Line Service Internet e-mail
http://www.omega.com info@omega.com
It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification. The information contained in this document is believed to be correct but OMEGA Engineering, Inc. accepts no liability for any errors it contains, and reserves the right to alter specifications without notice. WARNING: These products are not designed for use in, and should not be used for, patient connected applications.
This device is marked with the international caution symbol. It is important to read the Setup Guide before installing or commissioning this device as it contains important information relating to safety and EMC.
1. General Information and Features 2
2. Safety Considerations 3
3. Installation and Removal 4
3.1 Installation Clearance 5
3.2 Mounting on DIN Rail 6
3.3 Removal of Unit 7
4. Input and Output Connections 8
4.1 Block Diagram 8
4.2 Wiring for 115 Vac - Single Phase 9
4.3 Wiring for 230 Vac - Two Phase 10
5. Specifications 11 Input Power 11 Output Power 11 General 12 Wire Connections 12
6. Dimensions 13
7. Temperature Derating Graph 14
CONTENTS
1
The compact DRN power supplies are designed to supply well-regulated 24 volt DC power to sensors, signal conditioners, data acquisition systems and high level logic equipment.
Significant DRN features include: ¥ Tested isolation, primary to output ¥ Recessed live parts and connector screws ¥ Either 32mm or 35mm DIN rail mounting ¥ Wide input voltage tolerances ¥ Protective varistor input shunt ¥ Input AC spike rejection with LC filters ¥ LED power-on lamp ¥ Over-temperature protection ¥ Short circuit protection ¥ Low-ripple, well-regulated design
Features
GENERAL INFORMATION AND FEATURES
1
2
SAFETY CONSIDERATIONS
2
3
This device is marked with the international Caution symbol. It is important to read this manual before installing or commissioning this device as it contains important information relating to Safety and EMC (Electromagnetic Compatibility).
Unpacking & Inspection
Unpack the instrument and inspect for obvious shipping damage. Do not attempt to operate the unit if damage is found.
This instrument is a DIN rail mount device. Installation of this instrument should be done by Qualified personnel. In order to ensure safe operation, the following instructions should be followed.
This instrument has no power-on switch. An external switch or circuit-breaker shall be included in the building installation as a disconnecting device. It shall be marked to indicate this function, and it shall be in close proximity to the equipment within easy reach of the operator. The switch or circuit-breaker shall not interrupt the Protective Conductor (Earth wire), and it shall meet the relevant requirements of IEC 947Ð1 and IEC 947-3 (International Electrotechnical Commission). The switch shall not be incorporated in the mains supply cord.
Furthermore, to provide protection against excessive energy being drawn from the mains supply in case of a fault in the equipment, an overcurrent protection device shall be installed.
¥ The Protective Conductor must be connected for safety reasons. Check that the
power cable has the proper Earth wire, and it is properly connected. It is not safe to operate this unit without the Protective Conductor Terminal connected.
¥ Do not exceed voltage rating on the label located on the top of the instrument
housing. ¥ Always disconnect power before changing signal and power connections. ¥ Do not use this instrument on a work bench without its case for safety reasons. ¥ Do not operate this instrument in flammable or explosive atmospheres. ¥ Do not expose this instrument to rain or moisture. ¥ Unit mounting should allow for adequate ventilation to ensure instrument does not
exceed operating temperature rating. ¥ Use electrical wires with adequate size to handle mechanical strain and power
requirements. Install without exposing bare wire outside the connector to minimize
electrical shock hazards.
EMC Considerations
¥ Whenever EMC is an issue, always use shielded cables. ¥ Never run signal and power wires in the same conduit. ¥ Use signal wire connections with twisted-pair cables. ¥ Install Ferrite Bead(s) on signal wires close to the instrument if EMC problems
persist.
If a rail assembly is to be transported, then disconnection, dismounting and separate packing of the power supply is recommended.
For units that must be shipped installed on the rail, additional bracing to resist transportation shocks is recommended.
Do not attempt to install or connect to the power supply when the mains are energized.
Warning!
INSTALLATION AND REMOVAL
3
4
3.1 Installation Clearance
Ensure that there is enough room for mounting the power supply unit. There should be a minimum of 1" [25mm] spacing to allow sufficient air circulation for proper cooling.
Figure 3.1 Ñ Mounting
INSTALLATION AND REMOVAL
3
5
Signal Conditioner Modules
1"
24V-Bus
Power Supply
1"
3.2 Mounting on DIN Rail
To install unit onto DIN Rail
1. Tilt unit position mounting guide onto DIN Rail, as shown.
2. Push unit towards DIN Rail and it will snap into place.
Figure 3.2 Ñ Mounting on 35mm DIN Rail
Figure 3.3Ñ Mounted on 32mm DIN Rail
INSTALLATION AND REMOVAL
3
6
35mm Rail
Mounting Guide
1. Tilt
2. •Push to
• Snap on
32mm Rail
3
7
3.3 Removal of Unit
The mounting guide can remain on DIN Rail and Power Supply can be removed.
1. While holding mounting guide, push unit upwards and unit will detach from mounting guide.
Figure 3.4 Ñ Removal of Unit
Figure 3.5 Ñ Unit Removed
INSTALLATION AND REMOVAL
Mounting Guide
CASE
TAB MUST BE LOCATED AT BOTTOM.
35mm (SHOWN) or 32mm DIN RAIL
Hold Guide
Push Up
35mm Rail
4
8
4.1 Block Diagram of Power Supply
Figure 4.1 Ñ Block Diagram
4.2 Wiring
Warning: Do not turn on the ac power to the power supply
unit until you have completed all output connections. Failure to do so may result in injury!
This device must only be installed electrically by a specially trained electrician with corresponding qualifications.
Warning: To avoid potential electric shock use National Electrical Code (NEC) safety practices when wiring and connecting this unit to a power source.
INPUT AND OUTPUT CONNECTIONS
4
9
INPUT AND OUTPUT CONNECTIONS
4.2 Wiring (Continued)
115Vac - Single phase power wiring
Figure 4.2Ñ Wiring for 115Vac - Single Phase
Input Power
*•
USE A SWITCH TO APPLY
• +24V POWER TO THE LOAD,
• IF THE CAPACITANCE OF
• THE LOAD WILL DRAW MORE
• THAN 7 AMPS AT TURN ON.
USE AWG 12-26 WIRE
(for shielded wire connections, if necessary)
Earth
FUSE
Line
Switch
Neutral
Output Voltage
Switch
Earth Return +24 V
To Signal
Conditioner
Modules
4.3 Wiring (Continued)
230Vac - Two phase power wiring
Figure 4.3Ñ Wiring for 230Vac - Two Phase
INPUT AND OUTPUT CONNECTIONS
4
10
Output Voltage
(for shielded wire connections, if necessary)
Earth
FUSE 1
L1
Switch
L2
Earth
FUSE 2
Switch
*
*•
USE A SWITCH TO APPLY
• +24V POWER TO THE LOAD,
• IF THE CAPACITANCE OF
• THE LOAD WILL DRAW MORE
• THAN 7 AMPS AT TURN ON.
Earth Return +24 V
To Signal
Conditioner
Modules
SPECIFICATIONS
5
11
INPUT POWER
Input Voltage: 115 - 240Vac ±10% Frequency: 50/60 Hz Current: 0.400A @ 103Vac
0.190A @ 265Vac Overvoltage Protection: 275 Volt Varistor Overcurrent Protection: Fuse TR-5 800mA Time-lag / IEC 127-3 Input Wattage: 26 Watts
OUTPUT POWER
Output Voltage: 24Vdc ±2% @ 850mA (Resistive Load) Output Wattage: 20 Watts*
* For higher output wattage greater than 20 watts follow the chart on section 7, Figure 6.2.
Ripple: less than 100 mVrms Operating Indicator: Front Panel LED
Short-Circuit/ Overload Protection: Current limiting with automatic short-
circuit protection and temperature shutdown accomplished by the switcher.
Maximum number of Signal Conditioner Depends on module used and modules powered: configuration (6-10 modules)
SPECIFICATIONS
5
12
GENERAL
Operating Temperature: 23¡ to 122¡F(-5¡ to 50¡C)
Storage Temperature: -40¡ to 176¡F(-40¡ to 80¡C)
Mounting: 32 and 35mm DIN Rail
Size: Height: 3.00" (76mm)
Width: 0.9" (23mm) Depth: 3.67" (93mm)
Weight: 0.3 lbs. (0.14 kg)
Equipment Type: CLASS I Overvoltage: CAT II Pollution Degree: 2
Insulation input to ouput: Dielectric strength to 2500V transient
based on EN61010 for 265Vrms working voltage
WIRE CONNECTIONS
Screw down wire clamps, AWG 12 to 26 (ferrules recommended for stranded wire).
DIMENSIONS
6
13
3.67" (93mm)
3.00" (76mm)
0.9" (23mm)
INPUT AC VOLTAGE / POWER OUTPUT
7
14
Example: If ambient is 50¼C, maximum wattage is 21W max. for 120-265Vac. If unit is operated at 21W at an input voltage of 100V, the maximum ambient temperature allowed is 40¼C.
Figure 6.2 Ñ Temperature Derating Graph
MAXIMUM POWER OUTPUT
INPUT AC VOLTAGE
AMBIENT TEMPERATURE ¼C
120V 265V
115V
110V
105V
100V
25¼C
-5¼C 30¼C
35¼C 40¼C 45¼C
50¼C
20W
24W
23W
22W
21W
AC INPUT CURRENT @ 100VAC INPUT
OUTPUT POWER AC CURRENT
20W 338mA 21W 355mA 22W 373mA 23W 392mA 24W 412mA
WARRANTY/DISCLAIMER
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA Warranty adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGAÕs customers receive maximum coverage on each product.
If the unit should malfunction, it must be returned to the factory for evaluation. OMEGAÕs Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective it will be repaired or replaced at no charge. OMEGAÕs WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of being damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGAÕs control. Components which wear are not warranted, including but not limited to contact points, fuses, and triacs.
OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by it will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a ÒBasic ComponentÓ under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY/ DISCLAIMER language, and additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.
RETURN REQUESTS / INQUIRIES
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGAÕS CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit.
FOR WARRANTY
RETURNS, please have the following information available BEFORE contacting OMEGA:
1. P.O. number under which the product
was PURCHASED,
2. Model and serial number of the product
under warranty, and
3. Repair instructions and/or specific
problems relative to the product.
FOR NON-WARRANTY REPAIRS,
consult OMEGA for current repair charges. Have the following information available BEFORE contacting OMEGA:
1. P.O. number to cover the COST
of the repair,
2. Model and serial number of product, and
3. Repair instructions and/or specific
problems relative to the product.
OMEGAÕs policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC. © Copyright 1999 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied,
photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without prior written consent of OMEGA ENGINEERING, INC.
MADE
PATENT NOTICE: This product is covered by one or more of the following patents: U.S. Pat. No. Des. 336,895; 5,274,577 / Canada 2052599; 2052600 / Italy 1249456; 1250938 / France Brevet No. 91 12756 / Spain 2039150; 2048066 / UK Patent No. GB2 249 837; GB2 248 954 / Germany DE 41 34398 C2 Used Under License. Other International Patents Pending.
IN
USA
Where Do I Find Everything I Need for
Process Measurement and Control?
OMEGAÉOf Course!
TEMPERATURE
MU
Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies
MU
Wire: Thermocouple, RTD & Thermistor
MU
Calibrators & Ice Point References
MU
Recorders, Controllers & Process Monitors
MU
Infrared Pyrometers
PRESSURE, STRAIN AND FORCE
MU
Transducers & Strain Gauges
MU
Load Cells & Pressure Gauges
MU
Displacement Transducers
MU
Instrumentation & Accessories
FLOW/LEVEL
MU
Rotameters, Gas Mass Flowmeters & Flow Computers
MU
Air Velocity Indicators
MU
Turbine/Paddlewheel Systems
MU
Totalizers & Batch Controllers
pH/CONDUCTIVITY
MU
pH Electrodes, Testers & Accessories
MU
Benchtop/Laboratory Meters
MU
Controllers, Calibrators, Simulators & Pumps
MU
Industrial pH & Conductivity Equipment
DATA ACQUISITION
MU
Data Acquisition & Engineering Software
MU
Communications-Based Acquisition Systems
MU
Plug-in Cards for Apple, IBM & Compatibles
MU
Datalogging Systems
MU
Recorders, Printers & Plotters
HEATERS
MU
Heating Cable
MU
Cartridge & Strip Heaters
MU
Immersion & Band Heaters
MU
Flexible Heaters
MU
Laboratory Heaters
ENVIRONMENTAL MONITORING AND CONTROL
MU
Metering & Control Instrumentation
MU
Refractometers
MU
Pumps & Tubing
MU
Air, Soil & Water Monitors
MU
Industrial Water & Wastewater Treatment
MU
pH, Conductivity & Dissolved Oxygen Instruments
M-2814/0899