1 SAFETY
1.1 Intended Use:
WARNING: Use of this equipment in ways other than those described in this User
Guide may result in injury to persons or damage to property. Use this equipment
only as described in this User Guide.
OK International cannot be responsible for injuries or damages resulting from
unintended applications of its equipment. Unintended uses may result form taking
the following actions:
• Making changes to equipment that has not been recommended in the User
Guide
• Using incompatible or damaged replacement parts
• Using unapproved accessories or auxiliary equipment
1.2 Safety Precautions:
• Do not operate this unit in excess of maximum ratings/settings
• Always wear appropriate personal protective clothing or apparel
• Use only the following power adaptor models: PSA15R-240P(ZJ) or
• Care must be taken to prevent the ingress of corrosive or flammable fluid back
into the unit. If corrosive or flammable fluids are used, an inline filter (881000-000) must be installed on the dispenser to help prevent the fluids from
being sucked back into the unit
• The fluid being dispensed may be toxic and/or hazardous. Refer to Material
Safety Data Sheet for proper handling and safety precautions
• If a piston is not used with the barrel, an inline filter (881-000-000) must be
installed on the receiver head to help prevent fluids from being sucked back
into the unit. Also do not overfill the barrel and to lay the barrel on its side
• Do not smoke or use open flame when flammable materials are being dispensed
2
• This equipment is for indoor use only
2 SYMBOL DEFINITIONS
Symbol Definition
Power On/Off
Cycle Mode
Timer
Vacuum
3 SPECIFICATIONS
Size
Weight 1.2 kg (2.6 lbs)
Input Voltage 24VDC
Rated Power 10W
Air Input 100 psi (6.9 bar) Max.
Pollution Degree II
Installation Category I
Indoor Use Altitude up to 2,000m (6,562ft)
Operating Temperature 0˚C to 50˚C (32˚F to 122˚F)
Storage Temperature -10˚C to 60˚C (14˚F to 140˚F)
Reset Button
Display
Air Pressure Regulator
Pulsed Air Outlet
Vacuum Control
Setup Control Knob
Foot Switch Receptacle
Receiver Head air hose holder
Power Receptacle
I/O Connection
Exhaust Port
Accessory Air Outlet
Air Inlet
Cord Lock
3
4
5 CONNECTING THE UNIT
CAUTION: A 5-micron filter (TSD800-6) ,not included, must be installed with the unit to
ensure proper air filtration.
1
2
3
B
Figure 2.0
Items Description
1 To Air Source
2 Air Filter (not included)
3 Power Adapter
4 Foot Switch
6 SETUP INSTRUCTIONS
Refer to Figure 1.0
6.1 Manual/Purge Dispense Cycle Setting:
1. Turn on the unit by pressing the Power button (1).
2. Press the Mode button (2) until “PURGE” appears on the Display.
3. Turn up the air pressure by rotating the Air pressure regulator knob (5) until
the desired pressure is indicated on the Display.
4. After filling the barrel or using pre-packaged adhesive, attach syringe to
receiver head assembly. Make certain that the syringe locks into place.
5. Connect the plug end of the receiver head assembly to one of the air
dispense outlet (6).
6. If vacuum “suck back” is needed, rotate the Vacuum regulator (7) counter
clockwise until the desired vacuum pressure is indicated on the Display.
7. Press and hold the Foot switch to activate dispensed cycle. (The
Manual/Purge Mode is now activated)
6.2 Automatic Dispense Cycle Setting
6.2.1 Program selection
1. Press the reset button (3) until “P:” is flashing
2. Rotate the Setup Control Knob (8) to select desired program
6.2.2 Timed Mode setting
1. Press the Mode button (2) to select “TIMED” mode
2. Press and release the reset button (3) until the colon (:) in the
“TIME:” is flashing
3. Rotate the Setup control knob (8) to set the desired dispense time
4. Depress Foot switch to activate timed dispensed cycle
6.3 Teach Mode Setting
In the teach mode, the unit will accumulate time as long as the foot switch is
depressed. This is helpful in determining dispense time required when
dispense output is unknown.
1. Press the Mode button (2) to select “TEACH” mode
2. Press and release the reset button (3) until the dispense time = 0.000S
3. Press and hold down Foot switch. Dispense time will accumulate
during this time
4. Release Foot switch when proper amount of fluid is dispensed
5. Press the Mode button (2) to switch the “TIMED” mode
4
6.The dispenser is now set to repeat this time cycle.
6.4 Multiple Shots Setting:
Up to ten separate individual or sequenced shots can be stored in the DX350/DX-355.
1. Follow steps in section “6.2 Automatic Dispense Cycle Setting” to set
dispense time in desired programs
2. Press both the Reset button (3) and the Power button (1)
simultaneously to activate sequence program mode
3. Rotate the Setup Control knob to select total number of program to be
dispensed in sequence
4. Press both the Reset button (3) and Power button (1) to exit Multiple
Shots mode
6.5 Cycle Counter
The cycle counter records the numbers of automatic dispense cycle being
activated. Up to 65,535 cycles can be recorded. This number is shown at
the lower right hand corner of the LCD. To reset the counter, press and hold
the Reset button (3) and the Mode button (2) simultaneously until the
counter shows “0”.
6.6 Change Pressure and Vacuum Unit Display
1. Press and release the reset button (3) until the colon (:) in the
“PRESSURE:” or “VACUUM:” is flashing
2. Rotate the Setup control knob (8) to select desired unit display
5
6
7 TROUBLESHOOTING
PROBLEM POSSIBLE CAUSE CORRECTION
LCD does not
light
System will not
actuate
System will not
pressurize
System will not
pull vacuum
Inconsistent
dispensing
• No power input
• Foot switch not
plugged in or
improperly plugged
in
• Defective foot switch
• Broken wire or loose
connection inside
unit
• Defective solenoid
• Defective PC board
• Insufficient air
pressure
• Air hoses not
plugged in
• Regulator defective
• Vacuum setting is
too low
• Defective solenoid
• Defective vacuum
venturi
• Defective vacuum
needle valve
• Air bubbles in
adhesive
• Dispense time is too
low
• Dispense needle
started to clog
• Check power cord
connections
• Turn on power
• Check foot switch
connection
• Foot switch needs to be
repaired or replaced
• Unplug power cord and
disconnect air supply.
Remove cover and check
for broken wires or loose
connections
• Replace solenoid
• Replace PC board
• Increase air supply
pressure
• Check connection
• Replace regulator
• Increase vacuum setting
• Replace solenoid valve
• Replace venture
• Replace needle valve
• Reduce vacuum setting
• Increase dispensing time
• Replace needle
8 MAINTENANCE
The dispenser is designed and built to be relatively maintenance free. To assure
trouble free operation, the following recommendations should be followed:
1. Make certain air supply is clean and dry
2. Avoid turning barrels upside down or laying barrel so that material may
run through air line to internal components
3. Avoid connecting the unit to excessive moisture or solvent saturation.
4. Avoid connecting air supply exceeding 100 psi (6.9 bar) for the DX-350
and 15 psi (1.03 bar) for the DX-355
5. Use only Amyl Alcohol to clean outside surface of the main housing.
6. Use only soft cloth to clean the LCD
9 SPARE PARTS AND ACCESSORIES
For DX-3xx/2xx spare parts and accessories information, please visit the DX3xx/2xx User Guide webpage at http://www.okinternational.com
10 LIMITED WARRANTY
OK International warrants this product to the original purchaser for a period of one
(1) year from date of purchase to be free from material and workmanship defects but
not normal wear-and-tear, abuse and faulty installation. Defective product or
subassembly and components under warranty will be repaired or replaced (at OK
International's option) free of charge. Customer with defective product under
warranty must contact the nearest OK International office or distributor to secure a
return authorization prior to shipping the product to the assigned OK International
authorized service center. For nearest OK International office or distributor contact
information, please visit www.okinternational.com. OK International reserves the
right to make engineering product changes without notice.
11 I/O Configuration and End of Cycle Switch
For DX3xx/2xx I/O Configuration and End of Cycle Switch information, please visit
the DX-3xx/2xx User Guide webpage at http://www.okinternational.com
11 I/O Konfiguration und Schalter zum Beenden des Zyklus.............................10
1 SICHERHEITSHINWEISE
1.1 Bestimmungsgemäßer Gebrauch
WARNUNG: Wird dieses Gerät für andere Zwecke eingesetzt als in diesem
Benutzerhandbuch beschrieben, kann es zu Personen- oder Sachschäden
kommen. Setzen Sie das Gerät nur gemäß der Anleitung ein.
OK International ist nicht haftbar für Personen- oder Sachschäden, die auf nicht
zweckgemäßen Einsatz der Geräte zurückzuführen sind. Zu nicht
bestimmungsgemäßem Gebrauch zählen:
• Änderungen am Gerät, die nicht ausdrücklich im Benutzerhandbuch
empfohlen werden
• Einsatz nicht kompatibler oder beschädigter Ersatzteile
• Verwendung nicht zugelassenen Zubehörs oder Hilfsgeräte
1.2 Sicherheitsvorkehrungen
• Betreiben Sie das Gerät ausschließlich mit den maximal zugelassenen
Nennleistungen/Einstellungen.
• Tragen Sie immer geeignete Schutzkleidung.
Verwenden Sie nur die folgenden Adaptertypen: PSA15R-240P(ZJ) oder
• Achten Sie darauf, dass korrosive oder brennbare Medien nicht in das Gerät
zurückfließen. Wenn korrosive oder brennbare Medien eingesetzt werden,
muss ein Inline-Filter (881-000-000), nicht im Lieferumfang enthalten, am
Dosiersystem installiert werden, so dass die Medien nicht in das Gerät
zurück gesaugt werden können.
• Das dosierte Medium kann giftig und/oder gefährlich sein. Weitere
Einzelheiten bezüglich ordnungsgemäßer Handhabung und
Sicherheitsvorkehrungen finden Sie im Sicherheitsdatenblatt.
• Wird kein Stopfen mit der Kartusche eingesetzt, ist am Schlauch des
Kartuschenadapters ein Inline-Filter (881-000-000), nicht im Lieferumfang
enthalten, zu montieren, so dass die Medien nicht in das Dosiergerät zurück
gesaugt werden. Die Kartusche darf nicht überfüllt oder auf die Seite gelegt
werden.
• Rauchen oder offenes Feuer sind bei der Dosierung brennbarer Medien
untersagt.
• Dieses Gerät ist nur für den Gebrauch in geschlossenen Räumen geeignet.