OKI KGL5105KD User Manual

Electronic Components
50
50
April 21, 2006
KGL5105KD
11.3 Gbps Modulator Driver IC
Target Specifications
FEATURES
Maximum Input Data Rate : up to 11.3Gbps
Output Amplitude : up to 3.1Vpp
Crossing Point Controllability : 35% - 65%
Small Package : 4 x 4 mm QFN
Low Power Consumption
APPLICATIONS
Sonet OC-192 / STM64 Transmission System up to 11.3Gbps
WDM System
10GBE System
Optical Transponder/Transceiver/Transmitters
300Pin / XENPAK / Xpak / X2 /XFP
Sonet/SDH Test Equipment
FUNCTION DIAGRAM
VD1
VD2
INB IN
Crossing
Point
Control
OUT
OUTB
VB1 VB2
VC1 VC2
ABSOLUTE MAXIMUM RATINGS
Parameter Symbol Min Max Unit Note Supply Voltage VD1 -0.3 4.0 V Supply Voltage of Output Stage VD2 -0.3 4.3 V X-Point Control and Reference Voltage VB1/VB2 Output Amplitude Control Voltage VC1 -1.0 1.6 V Input Amplitude V in - 1.5 Vpp AC coupled Operating Temperature at Package Base Ts -10 100 °C Storage Temperature Tst -40 125 °C
-1.0 2.4 V
1/5
ODHKGL5105KD-01
60 40
Output X-Point (%)
Recommended Condition Range
Recommended Condition Range
Electronic Components
3Vpp Output Modulator Driver IC
RECOMMENDED OPERATING CONDITIONS
Parameter Symbol
Supply Voltage VD1 3.13 3.3 3.47 Supply Voltage of Output Stage VD2 3.5 3.7 3.8 V X-Point Control Voltage VB1 0.6 1.2 1.8 V X-Point Reference Voltage VB2 Output Amplitude Control Voltage VC1 0 - 1.3 V Single-ended Input Amplitude 0.4 - 1.2 Vpp Differential Input Amplitude for each port Operating Temperature at Package Base Ts -5 - 75 °C Input Interface AC coupled (External blocking capacitor is required) Output Interface AC coupled using external bias tee 2)
Vin
1) VB2 can be open or biased by the external circuit. For VB2 opened, VB2 is biased at about 0.364 x VD1.
2) Refer to TYPICAL APPLICATION ( Output AC coupled ) of page 4.
Min Typ Max Unit
V
1)
1.0 1.2 1.4 V
0.2 - 1.2 Vpp
Note
AC coupled AC coupled
ELECTRICAL CHARACTERISTICS (PROPOSAL SPECIFICATION)
Parameter Symbol Maximum Input Data Rate NRZ 11.3 - - Gbps Supply Current Id1 - 90 135 mA
Supply Current Id2 Minimum Output Amplitude 1) Vo(min)
Maximum Output Amplitude 1) Vo(max) Amplitude Monitor Resistance Rmod
X-Point Control Range
X-Point Stability Del (Xp) Output Rise/Fall Time Tr/Tf Input Return Loss S11
High Low
XPH 60 65 %
XPL
1) Measured at electrical input of DCA using Vamp function for each port
Note) X-Point Control Output Amplitude Control
X-Point Spec.
0.6
1.8
VB1 (V)
Condition Min Typ Max Unit
Maximum Amplitude
50 load, NRZ 50 load, NRZ
Ta = R.T.
50 load,
NRZ
50 load, -5–75°C
50 load, 20%/80%
100kHz–10GHz
- 130 180 mA
- 1.5 1.7 Vpp
2.9 3.1 - Vpp
- 2.0 - 
- 35 40 %
-10 - 10 %
- 40 ps
- 12 - dB
2.9
1.7
Output Amplitude (Vpp)
0 1.3
VC1 (V)
Amplitude Spec.