1.2 Overview of Parts and Controls ...................................................................................................................EN-5
1.3 Control Functions .......................................................................................................................................EN-9
3.1 Menu Structure ........................................................................................................................................EN-14
3.2 Menu Navigation .....................................................................................................................................EN-15
3.3 Calibration Menu .....................................................................................................................................EN-15
3.3.4 End Calibration .............................................................................................................................EN-17
3.4 Setup Menu .............................................................................................................................................EN-19
3.4.2 Legal for trade .............................................................................................................................. EN-19
3.4.3 Calibration Unit .............................................................................................................................EN-19
3.4.6 Power On Unit ..............................................................................................................................EN-21
3.4.7 Zero Range ..................................................................................................................................EN-21
3.4.8 End Setup ....................................................................................................................................EN-21
EN-23000 Series Indicators
TABLE OF CONTENTS (Cont.)
3.5 Readout Menu ......................................................................................................................................... EN-21
3.5.5 Auto Off Timer ..............................................................................................................................EN-22
3.5.6 End Readout ................................................................................................................................. EN-22
3.6 Mode Menu .............................................................................................................................................EN-23
3.6.2 Parts Counting Mode .....................................................................................................................EN-23
3.6.3 End Mode ....................................................................................................................................EN-23
3.7 Unit Menu ...............................................................................................................................................EN-24
3.7.2 Kilogram Unit ...............................................................................................................................EN-24
3.7.3 Pound Unit ...................................................................................................................................EN-24
3.7.4 Gram Unit ....................................................................................................................................EN-24
3.7.5 Ounce Unit ...................................................................................................................................EN-24
3.7.6 Pound Ounce Unit .........................................................................................................................EN-24
3.7.7 End Unit ......................................................................................................................................EN-24
3.8 Print Menu ..........................................................................................................................................EN-25
3.8.4 Stop Bit .......................................................................................................................................EN-25
3.8.6 Print Stable Data Only ...................................................................................................................EN-26
3.8.7 Auto Print .....................................................................................................................................EN-26
3.8.9 End Print .....................................................................................................................................EN-26
3.9 Menu Lock Menu .....................................................................................................................................EN-27
3.9.6 Lock Unit .....................................................................................................................................EN-27
3.9.8 End Lock .....................................................................................................................................EN-28
4.2 Zero Operation .........................................................................................................................................EN-28
4.4 Changing Units of Measure .......................................................................................................................EN-29
4.5 Printing Data ........................................................................................................................................... EN-29
4.6.2 Parts Counting .............................................................................................................................EN-29
5. SERIAL COMMUNICATION ..........................................................................................................................EN-31
5.2 Output Format ......................................................................................................................................... EN-32
6. LEGAL FOR TRADE ................................................................................................................................... EN-33
6.3.2 Audit Trail Seal .............................................................................................................................EN-34
7.1 Model T31P Cleaning ...............................................................................................................................EN-36
7.2 Model T31XW Cleaning ............................................................................................................................ EN-36
7.4 Service Information .................................................................................................................................. EN-37
8. TECHNICAL DATA .....................................................................................................................................EN-38
8.2 Accessories and Options ...........................................................................................................................EN-39
8.3 Drawings and Dimensions ........................................................................................................................EN-40
This manual contains installation, operation and maintenance instructions for the T31P and T31XW Indicators. Please read this
manual completely before installation and operation.
1.1 Safety Precautions
For safe and dependable operation of this equipment, please comply with the following safety precautions:
• Verify that the input voltage range printed on the data label matches the local AC power to be used.
• Make sure that the power cord does not pose a potential obstacle or tripping hazard.
• Use only approved accessories and peripherals.
• Operate the equipment only under ambient conditions specified in these instructions.
• Disconnect the equipment from the power supply before cleaning.
• Do not operate the equipment in hazardous or unstable environments.
• Do not immerse the equipment in water or other liquids.
• Service should only be performed by authorized personnel.
• The T31XW is supplied with a grounded power cable. Use only with a compatible grounded power outlet.
1.2 Overview of Parts and Controls
3
000
SERIES
On/Zero
Off
Yes
CALIBRATION
MODE
Print
Units
No
´0³
PCSNET TA RE
Function
Mode
Back
Tare
Menu
EN-53000 Series Indicators
1
TABLE 1-1. T31P PARTS.
ItemDescription
1Data Label
2
3
Exit
4
5
2Front Housing
3Control Panel
4Security Screw
5Key Hole (4) for wall
mounting
6Screw (4)
7Data Label
8Rear Housing
9Power Receptacle
10Strain Relief for Load Cell
Cable
11RS232 Connector
910
6
7
8
11
Figure 1-1. T31P Indicator.
EN-63000 Series Indicators
1.2 Overview of Parts and Controls (Cont.)
3000SERIESXTREMEW
CALIBRATION
´0³
On/Zero
Off
Yes
MODE
Print
Units
No
PCSNETTARE
Function
Mode
Back
Tare
Menu
Exit
1
TABLE 1-2. T31XW PARTS.
ItemDescription
1Data Label
2
2Front Housing
3Adjusting Knob (2)
4Control Panel
3
4
5Mounting Bracket
6Screw (4)
7Rear Housing
5
8Data Label
9Strain Relief for RS232
10Strain Relief for Load Cell
Cable
11Power cord
6
7
8
910
Figure 1-2. T31XW Indicator.
11
1.2 Overview of Parts and Controls (Cont.)
EN-73000 Series Indicators
J4
1
2
3
LOAD CELL WIRING
J5
W1 W2
45
Figure 1-3. Main PC Board.
6
OFF
J7 J6
7
TABLE 1-3. MAIN PC BOARD.
ItemDescription
1Keypad Connector J4 T31XW Model only
2Battery Connector (T31P only)
ON
8
9
+EXC +SIG -SIG -EXC
+SENS GND -SENS
RS232 WIRING
TXD GND
RXD
3Line Power Input
4Sense Jumper W1
5Load Cell Terminal Block J5
6Sense Jumper W2
7RS232 Terminal Block J7 T31XW Model only
8RS232 Connector J6 T31P Model only
9LFT On / Off Switch
EN-83000 Series Indicators
1.2 Overview of Parts and Controls (Cont.)
1
9
112
10
8
7
6
Figure 1-4. Controls and Indicators.
TABLE 1-4. CONTROL PANEL.
No.Designation
1Capacity Label Window
2TARE
3TARE symbol
4FUNCTION
5NET symbol
6PCS symbol
7PRINT
8Calibration Mode symbol
9Battery symbol (T31P only)
10ON/ZERO
11Center of Zero symbol
Menu
Units
5
button
Mode
button
Off
button
4
button
3
1.3 Control Functions
EN-93000 Series Indicators
TABLE 1-5. CONTROL FUNCTIONS.
Button
Primary Function
(Short Press)
Secondary Function
(Long Press)
Menu Function
(Short Press)
On/Zero
Off
Yes
ON/ZERO
If Indicator is On, sets
zero.
Off
Turns the Indicator on
or off.
Yes
Accepts the current
setting on the display.
Print
Units
No
PRINT
Sends the current value
to the COM port if
AUTOPRINT is set to Off.
Units
Changes the weighing
Unit.
No
Advances to the next
menu or menu item.
Rejects the current
setting on the display
and advances to the
next available setting.
Increments the value.
Function
Mode
Back
FUNCTION
Initiates an application
mode.
Mode
Allows changing the
application mode.
Press and hold allows
scrolling through modes.
Back
Moves Back to previous
menu item.
Decrements the value.
Tare
Menu
Exit
TARE
Performs a tare
operation.
Menu
Enter the User menu.
View the Audit Trail event
counters (extended
press)
Exit
Exits the User menu.
Aborts the calibration in
progress.
EN-103000 Series Indicators
2. INSTALLATION
2.1 Unpacking
Unpack the following items:
• T31P or T31XW Indicator
• AC Adapter (T31P only)
• Mounting Bracket (supplied with T31XW only)
• Knobs (2) (supplied with T31XW only)
• Capacity Label Sheet
• Instruction Manual CD
• Warranty Card
• LFT sealing Kit
2.2 External Connections
2.2.1 RS232 interface Cable to T31P
Connect the optional RS232 cable to the RS232 connector Figure 1-1, item 13).
PinConnection
1N/C
2TXD
3RXD
4N/C
5GND
6N/C
7N/C
8N/C
9N/C
4
5
9
Figure 2-1. RS232 Pins.
2
3
1
78
6
2.2.2 AC Power to T31P
Connect the AC Adapter to the power receptacle (Figure 1-1, item 8), then plug the AC Adapter into an electrical outlet.
2.2.3 AC Power to T31XW
Connect the AC plug to a properly grounded electrical outlet.
EN-113000 Series Indicators
2.2.4 Battery Power (T31P Only)
The indicator can be operated on the internal rechargeable battery when AC power is not available. The indicator will
automatically switch to battery operation if there is a power failure or the power cord is removed.
Note:
Before using the indicator for the first time, the internal rechargeable battery should be fully charged for up to
12 hours. The indicator can be operated during the charging process. The battery is protected against over
charging and the indicator can remain connected to the AC power line.
Connect AC power to the indicator and allow it to charge. While the battery is charging, the triangle above the battery function
symbol will light. When the battery is fully charged, this triangle will disappear.
The indicator can operate for up to 100 hours on a fully charged battery.
During battery operation, a flashing triangle above the battery function symbol indicates the battery is low and requires
recharging. Approximately 60 minutes of operation will remain when the battery symbol starts to blink. The indicator will
display Lo.BAT and automatically turn off when the battery is fully discharged.
CAUTION
BATTERY IS TO BE REPLACED ONLY BY AN AUTHORIZED OHAUS
SERVICE DEALER.
RISK OF EXPLOSION CAN OCCUR IF REPLACED WITH THE
WRONG TYPE OR CONNECTED IMPROPERLY.
Dispose of the lead acid battery according to local laws and regulations.
2.2.5 Mounting Bracket to T31XW
Align the mounting bracket over the threaded holes in the side of the indicator and install the knobs. Adjust the indicator to the
desired angle and tighten the knobs.
2.3 Internal Connections
Some connections require the housing to be opened.
2.3.1 Opening the Housing
CAUTION: ELECTRICAL SHOCK HAZARD. REMOVE ALL POWER CONNECTIONS TO THE INDICATOR
BEFORE SERVICING OR MAKING INTERNAL CONNECTIONS. THE HOUSING SHOULD ONLY BE OPENED
BY AUTHORIZED AND QUALIFIED PERSONNEL, SUCH AS AN ELECTRICAL TECHNICIAN.
EN-123000 Series Indicators
T31P
Remove the four Phillips head screws from the rear housing.
Open the housing being careful not to disturb the internal connections.
Once all connections are made, reattach the front housing.
T31XW
Remove the four hex head screws from the rear housing.
Open the housing by carefully pulling the top of the front housing forward.
Once all connections are made, reattach the front housing.
The screws should be tightened fully to maintain a watertight seal.
2.3.2 Scale Base to T31P or T31XW
Pass the load cell cable through the strain relief (Figure 1-1, item 9 or Figure 1-2,
item 10) and attach it to terminal block J5 (Figure 1-3, item 5).
Re-tighten the strain relief to ensure a watertight seal.
Jumper Connections
For a 4-wire load cell with no sense wires: Jumpers W2 and W3 must be shorted.
For a 6-wire load cell that includes sense wires, see Figure 2-2. Jumpers W2 and W3 must
be opened.
For load cells with an extra ground shield wire: Connect the shield to the center position (GND)
of J5.
PinConnection
J5-1+EXCITATION
J5-2+SENSE
J5-3+SIGNAL
J5-4GND
J5-5-SIGNAL
J5-6-SENSE
J5-7-EXCITATION
Figure 2-2. Jumper Connections.
After wiring is completed and jumpers are in place, replace the indicator housing screws. Make sure the strain relief is properly
tightened.
2.3.3 RS232 Interface Cable to T31XW
Pass the optional RS232 cable through the strain relief (Figure 1-2, item 9) and attach it to
terminal block J7 (Figure 1-3, item 7). Re-tighten the strain relief to ensure a water tight seal.
PinConnection
J7-1TXD
J7-2RXD
J7-3GND