Water Specialist
1” Control Valve Series Model: WS1EI
1.25” Control Valve Series Model: WS1.25EI
Operation and Instruction Manual for OEM Only.
Please Note: This operation and instruction manual is for the training of the
OEM and for the OEM to use to train their customers. This document is not
to be used as the complete system manual.
WS1EI & WS1.25EI Man u al
Table of Contents
Programming Instructions Refer to 1.5&2L Manual
Control Valve Function and Cycles of Operation Control Valve Function and Cycles of Operation 1 - 2
Drawings and Part Numbers
Front Cover and Drive Assembly Drawings and Part Numbers 1
WS1EI Drive Cap, Pistons and Spacer Stack Drawings and Part Numbers 2a
WS1.25EI Drive Cap, Pistons and Spacer Stack Drawings and Part Numbers 2b
WS1 & WS1.25 Identifi cation Figure Drawings and Part Numbers 2c
FOR INFORMATION COMMON TO ALL 1” & 1.25” CONTROL VALVEaS REFER TO THE WS1&WS1.25 COMMON
INFORMATION MANUAL
The common manual contains the Table of Contents shown below
Other Drawings and Part Numbers
Compliance T able No page number
Injector Cap, Injector Screen, Injector, Plug and O-ring Drawings and Part Numbers 3a
Injector Order Information Drawings and Part Numbers 3b
Injector Graphs US Units: Injector Draw, Slow Rinse and Total Flow Rates Drawings and Part Numbers 3c-3d
Injector Graphs Metric Units: Injector Draw, Slow Rinse and Total Flow Rates Drawings and Part Numbers 3e-3f
Refi ll Flow Control Assembly and Refi ll Port Plug Drawings and Part Numbers 4
Drain Line – 3/4” Drawings and Part Numbers 5
Drain Line – 1” Drawings and Part Numbers 6
Water Meter, Meter Plug and Mixing Valve Drawings and Part Numbers 7
Installation Fitting Assemblies Drawings and Part Numbers 8a – 8b
Bypass Valve Drawings and Part Numbers 9
Flow Diagrams – Service and Backwash Drawings and Part Numbers 10
Flow Diagrams – Downfl ow and Upfl ow Drawings and Part Numbers 11
Flow Diagrams – Rinse and Fill Drawings and Part Numbers 12
WS1 Wrench Drawings and Part Numbers 13
General Information General Information 1
General Warnings (Must appear in OEM’s manual) General Information 1
Specifi cations which must be included in OEM’s Manual General Information 2
Quick Reference Specifi cations General Information 2
Drive Assembly General Information 3
Drive Cap Assembly, Main Piston and Regenerant Piston General Information 3
Spacer Stack Assembly General Information 4
Injector Cap, Screen, Injector Plug and Injector General Information 4
Refi ll Flow Control Assembly or Refi ll Port Plug General Information 4
Drain Line Flow Control and Fitting Assembly General Information 5
Water Meter or Meter Plug General Information 6
Mixing Valve General Information 6
Installation Fitting Assemblies General Information 6
Bypass Valve General Information 7 - 8
Installation Installation 1 - 2
Service Instructions Service Instructions 1 - 5
Troubleshooting Troubleshooting 1 - 2
Limited W arranty Last Page
Control Valve Function and Cycles of Operation • Page 1
WS1EI & WS1.25EI Man u al
Control Valve Function and Cycles of Operation
This glass fi lled Noryl1 (or equivalent) fully automatic control valve is designed as the primary control center to direct and regulate
all cycles of a water softener or fi lter. The WS1EI and WS1.25EI control valves are only available in downfl ow regeneration. When
the WS1EI or WS1.25EI control valve is set up as a fi lter, the control valve can be set to perform downfl ow regeneration or simply
backwash. The control valve can be set to regenerate on demand (consumption of a predetermined amount of water) and/or as a
time clock (passage of a particular number of days). The control valve can be set so that a softener can meet the Water Quality
As so ci a tion (WQA) Standard S100 or NSF/ANSI Standard 44 effi ciency rating.
The control valve is compatible with a variety of regenerants and resin cleaners. The control valve is capable of routing the fl ow
of water in the necessary paths to regenerate or backwash water treatment systems. The injector regulates the fl ow of brine or
other regenerants. The control valve regulates the fl ow rates for backwashing, rinsing, and the replenishing of treated water into a
regenerant tank, when applicable.
The control valve uses no traditional fasteners (e.g. screws); instead clips, threaded caps, nuts and snap type latches are used. Caps
and nuts only need to be fi rmly hand tightened because radial seals are used. Tools required to service the valve include one small
blade screw driver, one large blade screw driver, pliers and a pair of hands. A plastic wrench is available which eliminates the need
for screwdrivers and pliers. Disassembly for servicing takes much less time than com pa ra ble products currently on the market.
Control valve in stal la tion is made easy because the distributor tube can be cut 12.7 mm (½”) above to 12.7 mm (½”) below the top
of tank thread. The distributor tube is held in place by an o-ring seal and the control valve also has a bayonet lock feature for upper
distributor baskets.
The AC adapter power pack comes with a 4.6 meter (15 foot) power cord and is designed for use with the control valve. The AC
adapter power pack is for dry location use only.
Table 1 shows the order of the cycles and available time for the WS1EI or WS1.25EI control valve. The WS1EI and WS1.25EI can
be used for downfl ow softener and fi lter applications as well as backwash-only fi lters.
Table 1
Regeneration Cycles and Times
WS1EI & WS1.25EI Cycles of Operation
Cycle
1. Backwash 1
st
(upfl ow)
2. Regenerant Draw/Slow Rinse (downfl ow)
3. Backwash 2
nd
(upfl ow)
4. Fast Rinse (downfl ow)
5. Regenerant Refi ll (with treated water)
Range of times (min.)
1 - 20 or OFF
1 - 99 or OFF
1 - 20 or OFF
1 - 20 or OFF
0.1 - 99.9 or OFF
6. Service (downfl ow)
1
Noryl is a trademark of General Electric.