WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating,Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
READ AND SAVE THESE INSTRUCTIONS
WARNING
6. Ducted fans must always be vented to the outdoors.
7. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit.
8. Never place a switch where it can be reached from a tub or shower.
9. This unit must be grounded.
10.When applicable local regulations comprise more restrictive
installation and/or certification requirements, the aforementioned requirements prevail on those of this document and the installer agrees to conform to these at his own expenses.
11.When performing installation, servicing or cleaning this unit, it
is recommended to wear safety glasses and gloves.
CAUTION
1.For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
2.To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power unit.
3.Please read specification label on product for further information
and requirements.
Installer: Leave this manual with the homeowner.
Homeowner: Use and Care information on page 4.
30042353C
!
TYPICAL INSTALLATIONS TYPICAL INSTALLATIONS
16”-ON-CENTER CEILING JOISTS
Housing mounted directly to joist.
24”-ON-CENTER CEILING JOISTS
Housing mounted additional framing.
MODELS BN100C • NT080C • NT100C
MODELS BN100C, NT080C & NT100C VENTILATION FANS
REGISTER YOUR PRODUCT ONLINE AT
• For Broan BN100C: www.broan.ca
• For NuTone NT080C or NT100C: www.nutone.ca
POWER CABLE
MOUNTING TABS
CEILING
JOIST
HOUSING
BH0009A
CEILING
MATERIAL
GRILLE
POWER CABLE
CEILING
MATERIAL
BH0010A
4" ROUND
DUCT
MOUNTING TABS
HOUSING
ADDITIONAL
GRILLE
FRAMING
CEILING
JOIST
Page 2
MODELS BN100C • NT080C • NT100C
SUSPENDED CEILINGS
Housing hung with wires - 3-point mount.
NEW CONSTRUCTION
1.Choose the location for your fan in the ceiling. For best possible performance, use the shortest possible duct run and a minimum number of elbows.
2.Position mounting tabs against joist so that bottom edge of housing will be flush with finished ceiling.
Additional positioning feature for 5/8”, 1” & 1¼” thick ceiling material:
Holes in corners of housing are labeled with various ceiling material thicknesses. Position housing so bottom edge of joist is visible through a matched set of holes. The housing is now in the proper position for that ceiling material thickness.
Additional positioning feature for 1/2” thick ceiling material: Bend two tabs, on side of housing, 90° outward. Lift housing
until tabs contact underside of joist.
Mark the keyhole slot on both mounting tabs.
NEW CONSTRUCTION (CONTD)
3.Set housing aside and drive nails partially into joist at the top of both keyhole marks.
4.Hang housing from nails and pound nails tight. To ensure a noise-free mount, pound another nail through the top hole of each mounting tab.
1.Choose the location for your fan in the ceiling. For best possible performance, use the shortest possible duct run and a minimum number of elbows.
2.In attic, position mounting brackets against joist. Trace outline of housing on ceiling material.
3.Set housing aside and cut ceiling opening slightly larger than marked.
EXISTING CONSTRUCTION
BOTTOM EDGE OF JOIST
TA B
TYPICAL INSTALLATIONS (CONTINUED) INSTALL THE HOUSING (CONTINUED)
INSTALL THE HOUSING
4" ROUND
DUCT
POWER
CABLE
MOUNTING
SUSPENDED
CEILING MATERIAL
BH0011A
HOUSING
GRILLE
TAB
1-1/4
1
5/8
BR0003
BR0004
Page 3
MODELS BN100C • NT080C • NT100C
1.Snap the damper/duct connector onto housing. Make sure that tabs on the connector lock into slots in housing. Top of damper/duct connector should be flush with top of housing.
2.Connect 4” round duct to damper/duct connector and extend duct to outside through a roof or wall cap. Check damper to make sure that it opens freely. Tape all duct connections to make them secure and air tight.
5.Additional mounting holes are provided for installations where access from above is inconvenient or not possible. Nail or screw housing directly to joists or framing.
4.Place housing in opening so that its bottom edge is flush with finished ceiling. Nail to joist through keyhole on both sides. To ensure a noise-free installation, drive another nail through the top hole of each mounting tab.
EXISTING CONSTRUCTION (CONTD)
1.Wire unit following diagram above. Run electrical cable as direct as possible to unit. Do not allow cable to touch sides or top of unit after installation is complete.
1.Squeeze grille springs together.
2.Insert springs into slots in motor plate.
BJ0003
ADDITIONAL
MOUNTING
HOLES
FLUSH
SCHEMATIC WIRING DIAGRAM
3.Push grille up against ceiling.
SLOT IN MOTOR PLATE
GRILLE SPRING
SPRING TABS
INSTALL THE HOUSING (CONTINUED) CONNECT THE WIRING