Nutone NS58000 User Manual

6-3/4”
1-3/8”
RANGE HOOD
SPECIFICATION SHEET
Timeless design that has become the icon of European style.
FEATURES
Wall mount
Finish: 430 Stainless Steel #4 Brushed
Width: 29-1/2”
Telescopic flue accommodates 8’ to 9’ ceilings
6” round duct connector/backdraft damper
Convertible to non-ducted operation (non-ducted
components included with hood)
Incandescent task lighting (2 x 40 watt, 120V, Type B10)
(bulbs included)
Three-speed electronic push-button control with blue
backlighting
10-minute delay-off
Single centrifugal blower
Dishwasher-safe filters feature a quick-release latch
Cord-connected
For indoor use only
OPTIONS
Replacement grease filters available (S99528311)
Replacement charcoal filters available
(Model ROUNDFILTER)
SPECIFICATIONS
8-3/4”
Min. 25-1/2” (Ducted)
Min. 28-1/4” (Non-Ducted)
Max. 40-1/4” (Ducted)
Max. 40-1/4” (Non-Ducted)
29-1/2”
Mount range hood so bottom of hood is
24” minimum above cooking surface.
9-7/8”
19-3/4”
VOLTS HZ AMPS CFM SONES DUCT MAX. NORM. MAX. NORM.
120 60 3.6 350 190 8.5 2.5 6” round
HVI-2100 CERTIFIED RATINGS comply with new testing technologies and procedures prescribed by the Home Ventilating Institute, for off-the-shelf products, as they are available to consumers. Product performance is rated at 0.1 in. static pressure, based on tests conducted in a state-of-the-art test laboratory. Sones are a measure of humanly-perceived loudness, based on laboratory measurements.
Broan-NuTone LLC Hartford, Wisconsin www.nutone.com 888-336-3948
REFERENCE QTY. REMARKS Project
Location
Architect
Engineer
Contractor
Submitted by Date
41A 99044878B
NS58000 SERIES WIRING NS58000 SERIES MOUNTING
WALL STUDS
LOCATE ELECTRICAL OUTLET WITHIN THESE AREAS. (Verify location will not interfere with duct, mounting brackets, and flue.)
1. GROUNDING INSTRUCTIONS This appliance must be grounded. In the event of an electrical
short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This appli­ance is equipped with a cord having a grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded.
NOTE:
A recessed “clock” outlet is recommended.
2. Position the electrical outlet within the space covered by the decorative flue and where it will not interfere with the round duct. Make sure the outlet does not interfere with the mounting bracket fastening area, ductwork, or where the decorative flue touches the wall.
4”
22”
11”
FRAMING BEHIND
DRYWALL
C
L
77⁄8
315⁄16
MOUNTING BRACKET LOCATION (ABOVE 36” HIGH COOKTOP)
345⁄8” = bottom of hood 24” above cooktop
1. Construct wood wall framing that is flush with interior surface of wall studs.
Make sure: a) the framing is centered over
installation location.
b) the height of the framing will allow
the mounting bracket to be secured to the framing within the dimensions shown.
2. After wall surface is finished, carefully center and level the hood mounting bracket and secure it to wall framing with (3) #8 x 1-1/2” mounting screws. Tighten the screws completely.
NOTE: Do not use drywall anchors.
19⁄16
CEILING DUCT HOOD DISTANCE ABOVE 36” COOK TOP (SEE NOTE 1) HEIGHT METHOD 24” 25” 26” 27” 28” 29” 30” 31” 32” 33” 34” 35” 36”
MOUNTING BRACKET LOCATION ABOVE 36” HIGH COOK TOP
DUCTED 34-5/8” 35-5/8” 36-5/8” 37-5/8” 38-5/8” 39-5/8” 40-5/8” 41-5/8” 42-5/8” 43-5/8” 44-5/8” --- ---
8 FEET NONDUCTED 34-5/8” 35-5/8” 36-5/8” 37-5/8” 38-5/8” 39-5/8” 40-5/8”
9 FEET
NOTES:
1. Minimum hood distance above cooktop must not be less than 24”. Distances over 36” above the cooktop are at the installer’s and user’s discretion - providing that ceiling height and flue length permit.
DUCTED
NONDUCTED --- --- --- --- --- --- --- --- 42-5/8” 43-5/8” 44-5/8” 45-5/8” 46-5/8”
---
---
---
---
Broan-NuTone LLC Hartford, Wisconsin www.nutone.com 888-336-3948
---
---
41-5/8” --- --- --- --- ---
---
---
42-5/8” 43-5/8” 44-5/8” 45-5/8” 46-5/8”
Loading...