NS58000 SERIES
RANGE HOOD
SPECIFICATION SHEET
Timeless design that has become the icon of
European style.
FEATURES
Wall mount
•
Finish: 430 Stainless Steel #4 Brushed
•
Width: 29-1/2”
•
Telescopic flue accommodates 8’ to 9’ ceilings
•
6” round duct connector/backdraft damper
•
Convertible to non-ducted operation (non-ducted
•
components included with hood)
Incandescent task lighting (2 x 40 watt, 120V, Type B10)
•
(bulbs included)
Three-speed electronic push-button control with blue
•
backlighting
10-minute delay-off
•
Single centrifugal blower
•
Dishwasher-safe filters feature a quick-release latch
•
Cord-connected
•
For indoor use only
•
OPTIONS
Replacement grease filters available (S99528311)
•
Replacement charcoal filters available
•
(Model ROUNDFILTER)
SPECIFICATIONS
8-3/4”
Min. 25-1/2” (Ducted)
Min. 28-1/4” (Non-Ducted)
Max. 40-1/4” (Ducted)
Max. 40-1/4” (Non-Ducted)
29-1/2”
Mount range hood so bottom of hood is
24” minimum above cooking surface.
9-7/8”
19-3/4”
VOLTS HZ AMPS CFM SONES DUCT
MAX. NORM. MAX. NORM.
120 60 3.6 350 190 8.5 2.5 6” round
HVI-2100 CERTIFIED RATINGS comply with new testing technologies and procedures
prescribed by the Home Ventilating Institute, for off-the-shelf products, as they are available
to consumers. Product performance is rated at 0.1 in. static pressure, based on tests
conducted in a state-of-the-art test laboratory. Sones are a measure of humanly-perceived
loudness, based on laboratory measurements.
Broan-NuTone LLC Hartford, Wisconsin www.nutone.com 888-336-3948
REFERENCE QTY. REMARKS Project
Location
Architect
Engineer
Contractor
Submitted by Date
41A 99044878B
NS58000 SERIES WIRING NS58000 SERIES MOUNTING
WALL STUDS
LOCATE
ELECTRICAL
OUTLET
WITHIN THESE
AREAS.
(Verify location
will not interfere
with duct,
mounting
brackets,
and flue.)
1. GROUNDING INSTRUCTIONS
This appliance must be grounded. In the event of an electrical
short circuit, grounding reduces the risk of electric shock by
providing an escape wire for the electric current. This appliance is equipped with a cord having a grounding wire with a
grounding plug. The plug must be plugged into an outlet that
is properly installed and grounded.
NOTE:
A recessed “clock” outlet is recommended.
2. Position the electrical outlet within the space covered
by the decorative flue and where it will not interfere
with the round duct. Make sure the outlet does not
interfere with the mounting bracket fastening area, ductwork,
or where the decorative flue touches the wall.
4”
22”
11”
FRAMING BEHIND
DRYWALL
C
L
77⁄8”
315⁄16”
MOUNTING BRACKET LOCATION
(ABOVE 36” HIGH COOKTOP)
345⁄8” = bottom of hood 24” above cooktop
1. Construct wood wall framing that is
flush with interior surface of wall studs.
Make sure:
a) the framing is centered over
installation location.
b) the height of the framing will allow
the mounting bracket to be secured
to the framing within the dimensions
shown.
2. After wall surface is finished, carefully
center and level the hood mounting
bracket and secure it to wall framing
with (3) #8 x 1-1/2” mounting screws.
Tighten the screws completely.
NOTE: Do not use drywall anchors.
19⁄16”
CEILING DUCT HOOD DISTANCE ABOVE 36” COOK TOP (SEE NOTE 1)
HEIGHT METHOD 24” 25” 26” 27” 28” 29” 30” 31” 32” 33” 34” 35” 36”
MOUNTING BRACKET LOCATION ABOVE 36” HIGH COOK TOP
DUCTED 34-5/8” 35-5/8” 36-5/8” 37-5/8” 38-5/8” 39-5/8” 40-5/8” 41-5/8” 42-5/8” 43-5/8” 44-5/8” --- ---
8 FEET
NONDUCTED 34-5/8” 35-5/8” 36-5/8” 37-5/8” 38-5/8” 39-5/8” 40-5/8”
9 FEET
NOTES:
1. Minimum hood distance above cooktop must not be less than 24”.
Distances over 36” above the cooktop are at the installer’s and user’s discretion - providing that ceiling height and flue length permit.
DUCTED
NONDUCTED --- --- --- --- --- --- --- --- 42-5/8” 43-5/8” 44-5/8” 45-5/8” 46-5/8”
---
---
---
---
Broan-NuTone LLC Hartford, Wisconsin www.nutone.com 888-336-3948
---
---
41-5/8” --- --- --- --- ---
---
---
42-5/8” 43-5/8” 44-5/8” 45-5/8” 46-5/8”