![](/html/af/af99/af992e5b6ddb0c702b82fd4ddcfc794bd8f79d8d5bd314c4f48881a96be51e99/bg1.png)
ERV100HC
Your Fresh Air Solution for Mild Humid Climates
Product
• 64 to 152 cfm (0.3 in. w.g.)
• 60 to 142 cfm (0.4 in. w.g.)
• Offers solid ventilation performance
• The enthalpic core will slow the moisture transfer
between the outdoor and indoor environments*
• Durability, reliability and performance are the
features that you will find with Broan Energy
Recovery Ventilators (ERV)
*The ability to slow the moisture transfer depends on
the outdoor humidity condition.
Features
• Best airflow, sensible energy recovery
and latent energy recovery of its class
• Smart Defrost System
• Ease of service
Ideal For
• Houses in moderate humid climates from
4,501 sq. ft. to 7,500 sq. ft.
• Contractors who want to offer added
value, quality and best performance
Benefits
• Enjoy the benefits of fresh air to dilute
contaminants without an energy penalty.
Our advanced enthalpic core transfers heat
from one airstream to the other, tempering
the air. This innovative technology reduces
moisture that enters the house during the summer.
• Failure protection system prevents the unit from
allowing cold air to enter into the house.
• All par
access on side panel.
ts removable in 5 minutes. Electrical
![](/html/af/af99/af992e5b6ddb0c702b82fd4ddcfc794bd8f79d8d5bd314c4f48881a96be51e99/bg2.png)
ERV100HC Specifications
Voltage: 120 V AC
Frequency: 60 Hz
Dimensions: 21.1" x 34.6" x 13.25"
Weight: 65 lbs
hipping Weight: 75 lbs
S
Warranty: 2 years, parts
HVI Rated of air flow: 169 cfm
Power Consumed (max): 150 Watts
Supply air duct connections: 6" Diameter
Exhaust air duct connections: 6" Diameter
Filter: 30 ppi washable reticulated foam
Cabinet: 20 ga. Pre-painted steel
Mounting: Suspension by chains and springs
W
all control modes: N/A
Power: 147 Watts
Current: 1.4 Amps
Energy Performance
Supply Net Average Recovery Sensible Moisture
Temperature Airflow Power Efficiency Effectiveness Transfer
Heating C F L/s cfm Watts % %
0 32 29 60 56 71 79 0.52
0 32 47 100 80 64 73 0.41
0 32 65 137 126 60 68 0.36
-15 5 31 65 64 56 81 0.41
Cooling 35 95 28 59 52 45
Sensible Apparent Latent Recovery
Total Recovery Efficiency
Ventilation Performance
External Static Net Supply Gross Airflow
Pressure Airflow Supply Exhaust
Pa In. W.g. L/s cfm L/s cfm L/s cfm
25 0.1 81 173 87 184 93 197
50 0.2 78 165 83 175 86 182
75 0.3 72 152 76 162 80 169
100 0.4 67 142 71 151 77 103
125 0.5 55 117 59 124 67 143
150 0.6 46 98 49 104 56 118
175 0.7 36 77 39 82 41 87
200 0.8
Note: Unit operating at maximum speed.
30 63 32 67 24 51
Installation
Options
t your Broan sales representative for information on attic installation requirements.
*Contac
www.Broan.com
Broan-NuTone, LLC, 926 W. State Street, Hartford, WI 53027 • 800-558-1711
In Canada call 888-882-7626
©2005 Broan-NuTone, LLC 9985 0754A 7/05
Attic*
Return-Return Connection
Return Connection — Extended Exhaust
Distributed By