NuTone CV400, SFDB-DC User Manual

HOMEOWNERS OPERATING INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
AB0022
30042420 Rev. E
Broan-NuTone LLC Hartford, Wisconsin
www.nutone.com
To register this product, visit www.nutone.com
CENTRAL VACUUM
POWER UNIT
HOUSEHOLD TYPE
CV400
MODEL NO. SFDB-DC
!
!
READ ALL INSTRUCTIONS BEFORE USING THIS APPLIANCE.
When using an electric appliance, basic precautions should always be followed, including the following:
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR PERSONAL INJURY:
• Do not use on wet surfaces or outdoors.
• Do not allow to be used as a toy. Close attention is necessary when used by or near children.
• Use only as described in this manual. Use only manufacturer's recommended attachments.
• Do not put any object into openings. Do not use with any opening blocked; keep free of dust, lint, hair, and anything that may reduce air flow.
• Keep hair, loose clothing, fingers and all parts of body away from openings and moving parts.
• Do not pick up anything that is burning or smoking, such as cigarettes, matches, or hot ashes.
• Do not use without dustbag or filter in place.
• Do not use to blow leaves or debris.
• Do not vacuum liquids or fine powders (such as drywall dust).
• Do not put any object on the unit.
• Ensure air flows freely to both side intake vents and exhausts unobstructed from top outlet.
• Do not install the unit horizontally.
• Do not use the pail as a wash pail.
• Do not use the pail as a stool.
• Turn off all controls before unplugging.
• Use extra care when cleaning on stairs.
• Avoid picking up sharp objects.
• Do not use to pick up flammable or combustible liquids such as gasoline or use in areas where they may be present.
• Do not use with damaged cord or plug. If appliance is not working as it should, if it has been dropped, damaged, left outdoors, or dropped into water, return it to a service center.
• Do not unplug the unit by pulling on cord. To unplug, grasp the plug, not the cord.
• Do not handle plug or appliance with wet hands.
• Connect to a properly grounded outlet only. See grounding instructions on page 8.
• Any servicing other than that recommended in this manual should be performed by an authorized service facility.
• We recommend that your unit be inspected by a specialized technician once a year.
- 2 -
!
IMPORTANT SAFETY INSTRUC-
SAVE THESE INSTRUCTIONS
1. OPERATION
The power unit is located away from the everyday living areas of your home — usually in the garage, basement, or utility room. Through a network of strong, lightweight tubing, the power unit connects to inlets strategically placed throughout your home. When you are ready to clean, attach the wand and cleaning tool onto the end of the hose. Open the inlet cover and insert the end of the hose into the inlet. For non-switched hoses: inserting the hose automatically turns on the power unit; removing the hose shuts off the power unit. Some hoses have switches which can be used to activate the power unit. As you vacuum, dirt and dust are transported to the power unit where they remain in a disposable bag.
NOTE: The rocker switch on the front of the power unit can be used to turn the
power unit on.
Use the cleaning tools as you would for any other vacuum cleaner. Avoid picking up pine needles, coffee sticks and other similar objects. These kinds of objects may become lodged in the hose or tubing.
- 3 -
2. DETAILED VIEW
LATC H
DEBRIS PAIL
DISPOSABLE BAG
SECONDARY FILTER
ROCKER SWITCH
EXHAUST OUTLET
INLET
BAG ADAPTER
INLET CHAMBER
AL0004
- 4 -
3. WHEN TO CHANGE BAG
With a 6 U.S. Gallons capacity, under normal conditions the bag requires changing approximately twice a year. If the bag is filled, you will notice a complete loss of vacuum in the system. Unless this loss of vacuum is caused by a blockage in the system, changing the bag will solve the problem.
NOTE: Even if not filled to capacity, if the bag seems tightly stretched when
removing the debris pail, changing the bag will prevent it from tearing.
4. BAG REPLACEMENT
1. To remove the disposable bag, release both latches on sides of the unit by pulling out and then pushing up. Remove the pail from unit. Grasp the edges of the bags’ collar and pull down. The bag will slide off easily. Do not pull on the bag.
2. Unfold new bag.
3. Grasp collar where indicated on the bag and insert over bag adapter. Be careful not to tear the bag. Ensure that the collar is positioned between the taper ring and the bag stopper on the bag adapter (see illustration below). Put the pail back in its place.
NOTE : A set of 3 replacement bags (model 391) may be purchased from you local
NuTone Sales Outlet. To locate your nearest NuTone Sales Outlet, call toll free 1-888-336-3948.
AO0032
BAG STOPPER
TAPER RING
AA0004
AO0026
- 5 -
5. SECONDARY FILTER
A secondary safety filter, located at the top of the inlet chamber provides protection against dirt being pulled into the motor if the disposable bag should accidentally be torn. This filter should be checked and cleaned if necessary, when replacement bag is installed. Simply brush filter clean. If the filter is excessively soiled, wash in a mild detergent and let it dry completely
before reinstalling.
5.1 REMOVING FILTER
Remove debris pail and disposable bag. Remove both locking sleeves from the retaining hooks. Carefully pull filter down to remove.
5.2 REINSTALLING FILTER
To reinstall the secondary filter, reverse the steps described above.
NOTE: A replacement secondary filter (part no. 10941310) may be purchased from
you local NuTone Sales Outlet. To locate your nearest NuTone Sales Outlet, call toll free 1-888-336-3948.
CAUTION
Operating the power unit without the secondary filter will void the warranty.
SECONDARY
FILTER
RETAINING
HOOKS
LOCKING
SLEEVES
WARNING
When performing installation, servicing or cleaning the unit, it is recommended to wear safety glasses and gloves.
!
AO0033
6. POWER UNIT INSTALLATION
6.1 LOCATING THE POWER UNIT
• Locate the power unit away from the general living area in an accessible location for cleaning and maintenance.
• Locate the power unit within 6 feet of a grounded electrical outlet. The power unit requires a 120 VAC power source.
• Do not locate the power unit close to a source of extreme heat (i.e.: water heater) or in an area with a high ambient temperature (i.e.: attic, furnace room).
• Do not locate the power unit where the temperature can drop below 0°C (32°F).
• If the power unit is located in a closet or a small utility room, make sure the area is well-ventilated (i.e.: with door louvers).
NOTE: Refer to NuTone website for information on tubing installation
(www.nutone.com).
6.2 MOUNTING POWER UNIT
1. Carefully remove debris pail from power unit. Make sure bag is properly installed in power unit. Remove accessories and installation kit. Securely reinstall pail.
2. Install the 3-way elbow on the back of the power unit and press firmly (do not glue
). Remove the plastic cap from the inlet opening only if your installation requires the connection into both inlets.
3. Install mounting bracket on a wall stud within 6 feet of a grounded electrical outlet, at the distances specified on illustration beside. Ensure that wall between mounting bracket and inlet is straight and leveled.
- 6 -
AO0034
CAUTION
Make sure to assemble the wall mounting bracket with the screws directly onto a wall stud for a solid installation.
3-WAY EL BOW DO NOT GLUE
REMOVE
PLASTIC CAP
(IF NEED BE)
MINIMUM WALL CLEARANCE
PVC TUBING STRAP
DIMENSIONS
INLET
TOP VIEW
CEILING
12" MINIMUM TO CEILING
INLET
30"
14" MIN.
INLET EXHAUST
WALL BRACKET
EXHAUST
12"
INLET
50"
FRONT VIEW
18" MINIMUM ABOVE FLOOR
FLOOR