NuTone 8814R User Manual

INSTALLATION INSTRUCTIONS
READ & SAVE THESE INSTRUCTIONS!
®
IMPORTANT SAFETY INSTRUCTIONS
WARNING: TO REDUCE THE RISK OF FIRE. ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
A. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer.
B. Before servicing or cleaning unit, switch power off at service
panel and lock service panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
CAUTION:
For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
INSTALLATION INSTRUCTIONS
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
A. Installation work and electrical wiring must be done by
qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
B. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
C. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities. D. Ducted fans must always be vented to the outdoors. E. If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application. F. NEVER place a switch where it can be reached from a tub or
shower. WARNING: To reduce the risk of fire or electric shock, do not
use this fan with any solid-state speed control.
Not for use in kitchens.
Suitable for use over tub or shower when installed in a GFI
(or GFCI) Protected Branch Circuit.
The exhaust fan consists of the housing, power unit/blower
assembly (motor, wheel, mounting plate,) grille and duct collar.
• Do not install in a ceiling insulated to a value greater than R-40.
Bathroom Exhaust Fan
MODEL: 8814R
SUITABLE FOR USE OVER TUB OR SHOWER ENCLOSURE WHEN INSTALLED IN A GFCI PROTECTED BRANCH CIRCUIT.
FOR BEST RESULTS
When installing the exhaust fan in a new construction site, install housing during the rough-in construction of the building. The blower unit and grille should be installed after the finished ceiling is in place.
To install the exhaust fan in an existing finished building requires an accessible area (attic or crawl space) above the planned location.
PLANNING DUCTWORK AND WIRING
DUCTWORK
1. Use 4" round duct.
2. Plan to run duct from discharge opening of fan to the outside.
For best fan performance, make duct run as short as possible.
3. Use optional NuTone ducting accessories as needed. Refer to
your NuTone catalog for a complete listing of available
accessories.
WIRING
Plan to run 120vAC house wiring (with ground) from power source, through a standard wall switch to junction box in fan housing.
FIGURE 1
DUCT COLLAR
HOUSING
SLOTS
POWER UNIT/ BLOWER ASSEMBLY
TABS
GRILLE
INSTALLATION IN A NEW CONSTRUCTION SITE
PREPARATION
Refer to Figure 1.
1. To remove blower/power unit assembly from housing: A. Unplug power unit. B. Remove screw (located next to plug-in receptacle)
which holds blower/power unit mounting plate in place. Save screw.
C. Lift mounting plate at end near the plug-in receptacle
until blower wheel clears the scroll.
D. Remove plate by pulling its tabs out of slots in housing.
Set blower/power unit aside until needed.
2. Remove one of the wiring knockout from housing.
MOUNTING THE HOUSING
Mounting Using Mounting Tabs Refer to Figure 2.
1. Locate fan housing next to ceiling joist.
2. Use wood screws (not provided) to loosely attach the housing to ceiling joist through the keyhole slots in mounting tabs.
3. Adjust housing so that it will be flush with finished ceiling. For the grille to fit properly, housing’s rim must not extend beyond finished ceiling surface.
4. When housing is properly adjusted, tighten screws in slots.
Mounting Using Hanger Bars (Hanger bars sold separately, order model HB4) Refer to Figure 3.
1. Insert hanger bars in slots provided in housing.
2. Locate fan housing between joists so that the bottom of the housing is even with the planned finished ceiling. Extend the hanger bars to the joists.
3. Use screws or nails (not provided) to secure hanger bars to ceiling joists.
INSTALLING THE DUCTWORK
1. Refer to Figure 2. Place duct collar over flanges at discharge opening of fan. Secure collar by snapping tabs into slots in flanges.
2. Run 4" round duct from outside to fan's discharge opening.
3. Connect duct to fan's duct collar.
WIRING
All wiring must comply with local codes and unit must
be properly grounded.
1. Run 120vAC house wiring (with ground) from wall switch to fan location.
2. Pull wire through access hole and into junction box.
3. Refer to Figure 4. Use approved wire nuts to connect house supply wires to fixture wires as follows: white to white; black to black. Connect green or bare ground wire to green ground lead.
POWER/BLOWER UNIT INSTALLATION
1. Place power/blower unit into housing so that mounting plate's tabs insert into slots in housing.
2. Press other end of mounting plate down until it is firmly seated over scroll and plug-in receptacles.
3. Secure mounting plate to housing with provided screw.
4. Insert motor plug into junction box receptacle.
FIGURE 2
FIGURE 3
FIGURE 4
DUCT COLLAR
FLANGES
WIRING KNOCKOUTS
MOUNTING TABS
JUNCTION BOX
GREEN GROUND LEAD
SWITCH BOX
EARTH GROUND
120vAC, 60 Hz HOUSE POWER
STANDARD WALL SWITCH (NOT INCLUDED) OR OPTIONAL NUTONE SPEED CONTROL
HANGER BARS (SOLD SEPARATELY)
INSTALLATION IN EXISTING CONSTRUCTION
Note: Installation in a finished house requires an accessible area (attic or crawl space) above the planned installation location.
1. After determining desired location for fan, drill a small hole in the ceiling. Place a coat hanger or other stiff wire up through hole to help in locating from above.
2. Place fan housing on top of ceiling surface, against a ceiling joist and use the housing as a template to mark area to be cut out.
3. After cutting out opening, mount housing in the opening using the hanger bars (sold separately) or mount directly to joist using mounting tabs.
A. Insert hanger bars in slots in housing. B. Position housing in opening so that bottom of
housing is flush with ceiling.
C. Use screws or nails (not provided) to secure
hanger bars to ceiling joists.
D. Complete installation as described above.
FIGURE 5
MOUNTING SPRINGS
INSERT TABS INTO SLOTS
GRILLE
Product specifications subject to change without notice.
4820 Red Bank Road, Cincinnati, Ohio 45227
Printed in U.S.A., Rev. 03/01, Part No. 87613
®
One Year Limited Warranty
WARRANTY OWNER: NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one (1) year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this one year period, NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS OR TUBES, FILTERS, DUCT, ROOF CAPS, WALL CAPS AND OTHER ACCESSORIES FOR DUCTING. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repair (other than by NuTone), faulty installation or installation contrary to recommended installation instructions.
The duration of any implied warranty is limited to the one year period as specified for the express warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you.
NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT NUTONE’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may
not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties.
WARRANTY SERVICE: To qualify for warranty service, you must (a) notify NuTone at the address stated below or telephone 1/800-543-8687, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present evidence of the original purchase date.
Date of Installation Builder or Installer
Model No. and Product Description
IF YOU NEED ASSISTANCE OR SERVICE:
For the location of your nearest NuTone Independent Authorized Service Center:
Residents of the contiguous United States Dial Free 1-800-543-8687
Please be prepared to provide:
Product model number • Date and Proof of purchase • The nature of the difficulty
Residents of Alaska or Hawaii should write to: NuTone Inc. Attn: Department of National Field Service, 4820 Red Bank Road, Cincinnati Ohio 45227-1599. Residents of Canada should write to: Broan-NuTone Canada, 1140 Tristar Drive, Mississauga, Ontario, Canada L5T 1H9.
Rev. 03/2001
Loading...
+ 7 hidden pages