NuTone 788CHNT Quick Start Manual

ADDITIONAL
JOIST
!
MODEL 788CHNT
DECORATIVE VENTILATION FAN WITH LIGHT
READ AND SAVE THESE INSTRUCTIONS
Page 1
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufac­turer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhaust­ing of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Do not install in a tub or shower enclosure.
8. Not for use in kitchens.
9. This unit must be grounded.
10. This unit is U.L. listed. Type I.C. inherently protected.
TYPICAL INSTALLATIONS
2 x 4
CEILING
JOIST
CEILING
MATERIAL
HOUSING
HOUSING
HOUSING MOUNTED
DIRECTLY TO JOIST
2x6 (or larger)
GRILLE
PAN
GLASS
CEILING JOIST or
TRUSS
CEILING
MATERIAL
HOUSING
HOUSING
HOUSING MOUNTED
TO 2x4 TRUSS
Discharge parallel to joists.
Discharge parallel to joists.
FRAMING
*
HOUSING
HOUSING
"I"
JOIST
CEILING
MATERIAL
GLASS LIGHT SHADE
GRILLE
PAN
"I"
HOUSING MOUNTED TO “I” JOIST
Requires additional framing
for mounting.
Discharge parallel to joists.
Additional framing must be a 2x6 (minimum height), at least 9-inches long.
*
CEILING JOIST or
TRUSS
GRILLE
GLASS
LIGHT SHADE
2 x 4
PAN
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2. This product is designed for installation in FLAT CEILINGS ONLY. Do not mount this product in a wall.
3. The light fixture assembly must be mounted to the fan hous­ing assembly included with this product. Do not mount the light fixture assembly to a wiring outlet box.
4. To avoid motor bearing damage and noisy and/or unbal­anced impellers, keep drywall spray, construction dust, etc. off power unit.
5. Please read specification label on product for further infor­mation and requirements.
Installer: Leave this manual with the homeowner.
Homeowner: Use and Care information on page 4.
PLAN THE INSTALLATION
INSULATION
(Place around and
over fan housing.)
FAN
HOUSING
POWER CABLE*
Seal gaps
around
housing.
4-IN. ROUND
DUCT*
*Purchase separately.
Seal duct
joints with
tape.
4-IN. ROUND
OR
ELBOWS*
ROOF CAP*
(with built-in
damper)
Keep duct
runs short.
WALL CAP* (with built-in
damper)
PREPARE THE HOUSING
1. Unplug blower and remove (3) screws securing blower assembly to housing.
MODEL 788CHNT
Page 2
INSTALL THE HOUSING
New Construction
1. Choose the location for your fan/light in the ceiling. For best possible performance, use the shortest possible duct run and a minimum number of elbows.
TAB
2. Remove blower assembly from housing and set blower assembly aside.
TAB
MOUNTING SCREWS
2. Position fan housing against joist so that bottom edge of housing will be flush with finished ceiling.
Additional positioning feature for 1/2” thick
ceiling material:
Bend two tabs, on side of housing,
housing until tabs contact bottom edge of joist.
3. Use (4) mounting screws (included) to attach housing to joist.
BOTTOM EDGE OF JOIST
900 outward. Lift
Existing Construction
1. Choose the location for your fan/light in the ceiling. For best possible performance, use the shortest possible duct run and a minimum number of elbows.
2. In attic, position fan housing against joist. Trace outline of housing on ceiling
material.
3. Remove wiring plate from housing and set plate aside.
3. Set housing aside and cut ceiling opening slightly larger than marked.
UNIT
SWITCH BOX
LINE
4. Place housing in
MATERIAL & HOUSING
opening so that its bottom edge is flush with finished ceiling. Screw housing to joist through holes in housing as shown.
5. Seal between ceiling material and
SEAL BETWEEN CEILING
housing to prevent air leakage.
MOUNTING SCREWS
INSTALL THE DUCTWORK
NOTE: The duct connector has a counter-balanced damper
flap. The flap will be “open” approx. 1” when duct connector is attached to housing. This design permits insulation to be in direct contact with fan/light housing per UL (Underwriters Laboratories) standards. The slightest backdraft, however, will close the damper flap, preventing air from entering unit or finished space.
1. Connect 4” round duct to damper/ duct connector and extend duct to outside through a roof or wall cap. Check damper to make sure that it opens freely. Tape all duct connections to make them secure and air tight.
MODEL 788CHNT
Page 3
FINISH THE INSTALLATION
1. Re-install blower assembly removed in Step 1 under “PREPARE THE HOUSING”. Plug blower into black receptacle.
2. Attach grille pan mounting brackets to housing with screws (included). Make sure brackets face inward.
CONNECT THE WIRING
SCHEMATIC WIRING DIAGRAM
LIGHT SWITCH
VENT SWITCH
BLK WHT
IN
GRD
LIGHT
FAN
DUAL CONTROL
(purchase separately)
BLACK WHITE BLUE
SWITCH BOX
120 VAC LINE IN
RED
BLK
WHT GRD
BLU
BLK
RED GROUND
(bare)
LIGHT
(WHITE)
(BLACK)
1. Wire unit as shown. Re-install wiring plate removed in Step 2 under “PREPARE THE HOUSING”.
2. Run electrical cable as direct as possible to unit. Do not allow cable to touch sides or top of unit after installation is complete.
VENT
BLACK
RECEPTACLE
(FAN)
WHITE
RECEPTACLE
(LIGHT)
WHT
WHT
3. Locate grille pan over fan housing and connect light plug into white receptacle in fan housing.
4. Attach grille pan to mounting brackets with (2) screws (included).
5. Thread rod onto threaded stud in center of grille pan. Tighten rod securely.
METAL
WASHER
FELT
WASHERS
FELT
WASHER
6. Install bulbs. Use 13­watt (maximum), GU24 type, fluorescent bulbs.
7. Place washers and glass shade over mounting rod and align shade over grille pan. Secure shade to grille pan with washer and finial nut as shown.
8. Restore electrical power and check operation of the unit.
Loading...
+ 5 hidden pages