NuTone 769RL User Manual

Architectural & Engineering Specifications
March 2004
Economy
Fan-Light
Combination
MODEL: 769RL
DESCRIPTION
• Efficient ventilation and bright light in one easy installation. Fan and light operates separately or together.
• Quiet operation with one-piece molded blower wheel, silent backdraft damper.
• White polymeric grille with break resistant lens – 10
1
⁄4" x 101⁄2".
• 9" x 9" x 5
3
⁄4" steel housing.
• Plug-in motor and light.
• Uses 4" duct.
• For baths up to 65 sq. ft., other rooms up to 85 sq. ft.
• Refer to NuTone's catalog for a complete listing of accessories to effectively adapt this Fan-Light Combination to your construction requirements.
DESIGN FEATURES
Air Delivery: 70 CFM at 0.10" S.P. Sound Level: 3.0 Sones. Dimensions: Housing: 9" x 9" x 53⁄4".
Grille: 101⁄4" x 101⁄2".
Material & Finish: Housing: Galvanized steel.
Grille: White polymeric. Motor: Shaded pole, thermally protected. Blower Wheel: One-piece polypropylene,
43⁄4" diameter.
Duct Size: 4" diameter. Electrical Rating: 120v, 60Hz, 2.0 A.
ARCHITECT'S SPECIFICATIONS
Fan-Light Combination shall be NuTone Model Number 769RL as manufactured by NuTone according to listed specifications. Fan shall ventilate 70 CFM at 0.10 S.P. at a sound level of 3.0 Sones. Housing shall be 9" x 9" x 53⁄
4
"
and connect to 4" duct.
INSTALLATION
• Suitable for use over tub or shower enclosure when
installed in a GFI protected branch circuit.
• Installation instructions are included with each unit.
• Type IC for use with thermal insulation.
• Not for use in kitchens.
• Not for use with solid state speed controls.
REFERENCE QTY. REMARKS Project
Location
Architect
Engineer
Contractor
Submitted by Date
CERTIFIED TEST DATA
HVI-2100 CERTIFIED RATINGS comply with new testing technologies and procedures prescribed by the Home Ventilating Institute, for off-the-shelf products, as they are available to consumers. Product performance is rated at 0.1 in. static pressure, based on tests conducted in AMCA's state-of-the-art test laboratory. Sones are a measure of humanly-perceived loudness, based on laboratory measurements. This NuTone model is listed by Underwriters' Laboratories Inc.
10 050
0
0.0 0
0.10
0.20
0.3 0
0.4 0
0.5 0
STATIC PRESSURE–INCHES OF WATER
50 Feet
40 Feet
30 Feet
20 Feet
10 Feet
CFM CUBIC FEET PER MINUTE
75 12525
AIR PERFORMANCE CURVE
(4 In. Duct to 10 Foot Lengths)
STATIC PRESSURE INCHES OF WATER
CFM
0.05
78 75 73 70 67 64 61 57 54
0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45
The air delivery of a ventilating system may be determined by:
1. Determine the equivalent duct length for each 90 degree
elbow by adding one foot of duct length for each inch of
duct diameter, i.e., a 4 inch diameter duct elbow equals
4 feet equivalent duct length and an 8 inch diameter
duct elbow equals 8 feet equivalent duct length.
2. Add the total straight length of duct and the equivalent
length for each elbow to obtain the total equivalent duct
length.
3. Locate the intersection of the fan performance curve and
the total equivalent duct length curves and draw a
vertical line down to the CFM scale and read the system
air performance.
(NOTE: 31⁄4" x 10" duct equals 6 inch diameter duct.)
DUCT COLLAR
HOUSING
TABS
GRILLE
POWER UNIT/ BLOWER ASSEMBLY
REFLECTOR
LAMP SOCKET
LENS
SLOTS
HANGER
BARS
(SOLD
SEPAR-
ATELY)
Product specifications subject to change without notice.
NuTone, Inc., 4820 Red Bank Road, Cincinnati, Ohio 45227
Printed in U.S.A.
Loading...