NuTone 742RBNT, 742WHNT, 742SNNT User Manual

MODELS 742RBNT • 742WHNT • 742SNNT
G
G
r
HOUSING
MOUNTING TABS
POWER CABLE
4" ROUND
DUCT
ADDITIONAL
FRAMING
"I"
JOIST
"I"
JOIST
CEILING
MATERIAL
GRILLE
PAN
GLASS
LIGHT SHADE
DECORATIVE SERIES CEILING VENTILATORS
READ AND SAVE THESE INSTRUCTIONS
Page 1
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel and lock the service discon­necting means to prevent power from being switched on accidentally. When the service dis­connecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, includ­ing fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chim­ney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the Ameri­can Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the lo­cal code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utili­ties.
6. Ducted fans must always be vented to the out­doors.
7. NEVER place a switch where it can be reached from a tub or shower.
8. This unit must be grounded.
9. This unit is U.L. listed. Type I.C. inherently pro­tected.
!
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2. This product is designed for ceiling installation only. This product is designed for installation in ceilings up to a 12/12 pitch. Ductwork must point up. DO NOT MOUNT THIS PRODUCT IN A WALL.
3. The light fixture assembly must be mounted to the fan housing assembly included with this prod­uct. Do not mount the light fixture assembly
to a wiring outlet box.
4. To avoid motor bearing damage and noisy and/
5. Please read specification label on product for
or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
further information and requirements.
TYPICAL INSTALLATIONS
4" ROUND
POWER CABLE
MOUNTING TABS
CEILING
JOIST
CEILING
MATERIAL
HOUSING
HOUSING MOUNTED DIRECTLY TO JOIST
2x6 (or larger)
GRILLE
PAN
GLASS
LIGHT SHADE
POWER CABLE
MOUNTING TABS
HOUSING
CEILING
MATERIAL
GLASS
LIGHT SHADE
HOUSING MOUNTED
TO ADDITIONAL FRAMING
Discharge 900 to joists.
Discharge parallel to joists.
POWER CABLE
2 x 4 CEILING JOIST or
TRUSS
CEILING
MATERIAL
MOUNTING
HOUSING
HOUSING MOUNTED
TO 2x4 TRUSS
Requires additional framing
for mounting tabs.
Discharge parallel to joists.
POWER CABLE
"I"
JOIST
CEILING
MATERIAL
GLASS LIGHT SHADE
MOUNTING
HOUSING
HOUSING MOUNTED TO “I” JOIST
Requires additional framing
for mounting tabs.
Discharge parallel to joists.
Additional framing must be a 2x6 (minimum height), at least 9-inches long.
*
TABS
TABS
ADDITIONAL
FRAMING
GRILLE
GLASS
LIGHT SHADE
ADDITIONAL
FRAMING
"I"
JOIST
GRILLE
PAN
*
2 x 4 CEILING JOIST or
TRUSS
PAN
*
POWER CABLE
MOUNTING TABS
HOUSING
2 x 4 CEILING JOIST or
TRUSS
GLASS
LIGHT SHADE
HOUSING MOUNTED TO 2x4 TRUSS
Requires additional framing
for mounting tabs.
Discharge 900 to joists.
HOUSING MOUNTED TO “I” JOIST
Requires additional framing
for mounting tabs.
Discharge 900 to joists.
Installer: Leave this manual with the homeowner.
Homeowner: Use and Care information on page 4.
DUCT
GRILLE PAN
4" ROUND
DUCT
GRILLE PAN
ADDITIONAL
FRAMING
ADDITIONAL
FRAMING
CEILING
MATERIAL
CEILIN JOIST o
*
*
CEILIN
JOIST
*
2 x 4
TRUSS
MODELS 742RBNT • 742WHNT • 742SNNT
Page 2
TYPICAL INSTALLATIONS (continued)
4" ROUND
DUCT
SUSPENDED
CEILING
MATERIAL
HOUSING
POWER
CABLE
MOUNTING
TAB
GRILLE
PAN
GLASS
LIGHT SHADE
SUSPENDED CEILINGS
Housing hung with wires - 3-point mount.
INSTALL THE HOUSING
THE FOLLOWING INSTALLATION ILLUSTRATIONS SHOW 2 X 6 JOISTS. IF YOU HAVE A TRUSS OR “I”-JOIST INSTALLATION, MOUNT THE VENTILATOR TO THE ADDITIONAL FRAMING IN THE SAME MANNER. (Additional framing must be a 2x6 (mini­mum height), at least 9-inches long.)
- PLEASE NOTE -
INSTALL THE HOUSING (continued)
New Construction
3. Set housing aside and drive nails partially into joist at the top of both keyhole marks.
New Construction
1. Choose the location for your fan in the ceiling. For best possible performance, use the shortest possible duct run and a minimum number of elbows.
HOLES
TAB
1-1/4
1
5/8
BOTTOM EDGE OF JOIST
2. Position mounting brackets against joist so that bottom edge of housing will be flush with finished ceiling.
Additional positioning feature for 5/8”, 1”, & 1-1/4” thick ceiling material:
Holes in corners of housing are labeled with various ceiling material thicknesses. Position housing so bottom edge of joist is visible through a matched set of holes. The housing is now in the proper position for that ceiling material thickness.
Additional positioning feature for 1/2” thick ceiling material:
Bend two tabs, on side of housing, housing until tabs contact underside of joist.
Mark the keyhole slot on both mounting brackets.
900 outward. Lift
4. Hang housing from nails and pound nails tight. To ensure a noise-free mount, pound another nail through the top hole of each mounting tab.
Existing Construction
1. Choose the location for your fan/light in the ceiling. For best possible performance, use the shortest possible duct run and a minimum number of elbows.
2. In attic, position mounting brackets against joist. Trace outline of housing on ceiling material.
3. Set housing aside and cut ceiling opening slightly larger than marked.
INSTALL THE HOUSING
MODELS 742RBNT • 742WHNT • 742SNNT
Page 3
CONNECT THE WIRING
(continued)
Existing Construction
4. Place housing in opening so that its bottom edge is flush with finished ceiling. Nail to joist through keyhole on both sides. To ensure a noise-free installation, drive another nail through the top hole of each mounting bracket.
ADDITIONAL
MOUNTING
HOLES
5. Additional mounting holes are provided for installations where access from above is inconvenient or not possible. Nail or screw housing directly to joists or framing.
SCHEMATIC WIRING DIAGRAM
LIGHT SWITCH
VENT SWITCH
LINE
IN
DUAL CONTROL
(purchase separately)
LIGHT
FAN
BLK WHT GRD
SWITCH BOX
SWITCH BOX
120 VAC
LINE IN
BLACK WHITE BLUE
RED
BLK
WHT GRD
BLU
BLK
RED GROUND
(bare)
WIRING
PLATE
LIGHT
(WHITE)
(BLACK)
VENT
UNIT
WHT
WHT
WHITE
RECEPTACLE
(LIGHT)
BLACK
RECEPTACLE
(FAN)
1. Wire unit following diagram above. Run electrical cable as direct as possible to unit. Do not allow cable to touch sides or top of unit after installation is complete.
ATTACH THE GRILLE PAN AND GLASS SHADE
INSTALL THE DUCTWORK
FLUSH
NOTE: The duct connector
has a counter-balanced damper flap. The flap will be "open" approx. 1" when duct connector is attached to hous­ing. This design permits insulation to be in direct contact with fan/light housing per UL (Underwriters Laboratories) stan­dards. The slightest backdraft, however, will close the damper flap, preventing air from entering unit or finished space.
1. Snap the damper/duct connector onto housing. Make sure that tabs on the connector lock into slots in housing. Top of damper/duct connector should be flush with top of hous­ing.
2. Connect 4” round duct to damper/duct connector and ex­tend duct to outside through a roof or wall cap. Check damper to make sure that it opens freely. Tape all duct connections to make them secure and air tight.
1. Locate the grille pan over the fan housing and con­nect the wiring harness
GRILLE
PAN
GRILLE
SCREW
plug into white receptacle in the fan housing.
2. Insert rod through center hole of grille pan. Use washer between collar on rod and pan.
WASHER
ROD
COLLAR
3. Thread rod onto grille screw in housing, until pan is tight against ceiling.
4. Install bulbs. (see "Bulb Replace­ment" chart on next page for proper bulbs for your model).
5. Place glass shade over mounting rod and align shade onto grille pan. Secure glass shade to grille pan with finial cap and finial nut as shown.
6. Restore electrical power and check operation of the unit.
Loading...
+ 5 hidden pages