Electrical Characteristics
Over recommended operating free air temperature range (unless otherwise noted) (Continued)
Symbol Parameter Conditions Min
Typ
Max Units
(Note 1)
I
OS
Short Circuit V
CC
e
Max DM54
b
20
b
57
mA
Output Current (Note 2)
DM74
b
20
b
57
I
CCH
Supply Current V
CC
e
Max DM54 85
mA
with Outputs High (Note 3)
DM74 59 94
I
CCL
Supply Current V
CC
e
Max DM54 91
mA
with Outputs Low (Note 4)
DM74 63 101
Note 1: All typicals are at V
CC
e
5V, T
A
e
25§C.
Note 2: Not more than one output should be shorted at a time.
Note 3: I
CCH
is measured with the LOAD high, then again with the LOAD low, with all inputs high and all outputs open.
Note 4: I
CCL
is measured with the CLOCK high, then again with the CLOCK input low, with all inputs low and all outputs open.
Note 5: Applies to 163 which has synchronous clear inputs.
Note 6: T
A
e
25§C and V
CC
e
5V.
Switching Characteristics at V
CC
e
5V and T
A
e
25§C (See Section 1 for Test Waveforms and Output Load)
Symbol Parameter
From (Input)
R
L
e
400X,C
L
e
15 pF
Units
To (Output)
Min Max
f
MAX
Maximum Clock
25 MHz
Frequency
t
PLH
Propagation Delay Time Clock to
35 ns
Low to High Level Output Ripple Carry
t
PHL
Propagation Delay Time Clock to
35 ns
High to Low Level Output Ripple Carry
t
PLH
Propagation Delay Time Clock
20 ns
Low to High Level Output (Load High) to Q
t
PHL
Propagation Delay Time Clock
23 ns
High to Low Level Output (Load High) to Q
t
PLH
Propagation Delay Time Clock
25 ns
Low to High Level Output (Load Low) to Q
t
PHL
Propagation Delay Time Clock
29 ns
High to Low Level Output (Load Low) to Q
t
PLH
Propagation Delay Time Enable T to
16 ns
Low to High Level Output Ripple Carry
t
PHL
Propagation Delay Time Enable T to
16 ns
High to Low Level Output Ripple Carry
t
PHL
Propagation Delay Time Clear (Note 7)
38 ns
High to Low Level Output to Q
Note 7: Propagation delay for clearing is measured from the clear input for the 161 or from the clock input transition for the 163.
3