North Star NST30ED, NST45ED1, NST70ED1 User Manual

Designed, Engineered & Assembled in the U.S.A.
Models NST30ED
NST45ED1 NST70ED1
How to install, operate
and maintain your Demand
Controlled Water Softener
installing, operating or maintaining your water
softener, call our toll free number:
1-800-972-0135
or visit www.northstarwater.com
When you call, please be prepared to provide
the model and serial number of your product,
found on the rating decal, located on the back
of the controller top cover.
Systems tested and certified by NSF International
against NSF/ANSI Standard 44
for hardness reduction and efficiency,
and certified to NSF/ANSI Standard 372.
Systems tested and certified by the Water Quality
Association against CSA B483.1.
Manufactured and warranted by
North Star Water Treatment Systems
1890 Woodlane Drive Woodbury, MN 55125
Installation and Operation Manual
7366546 (Rev. E 9/1/18)
TABLE OF CONTENTS
Page
pecifications & Performance Claims . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
S
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Before You Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Installation Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
ypical Installation Illustrations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
T
Installation Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-10
rogramming the Electronic Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-12
P
Controller Features / Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Wiring Schematic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Routine Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15-17
Exploded View & Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18-23
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Inspect Shipment
The parts required to assemble and install the water softener are included with the unit. Thoroughly check the water softener for possible shipping damage and parts loss. Also inspect and note any damage to the shipping carton.
Packing List
All Models:
Model NST30ED:
Remove and discard (or recycle) all packing materials. To avoid loss of small parts, we suggest you keep the small parts in the parts bag until you are ready to use them.
Adaptor ElbowHose Clamps
GrommetDrain Hose
Models NST45ED1:
& NST70ED1:
Bypass Valve
Bypass Valve Clips
Clips
2
Installation
Adaptors
O-rings
FIG. 1
Specifications & Performance Claims
hese models are efficiency rated. The efficiency rating is valid only at the minimum salt dose. The softeners have
T a demand initiated regeneration (D.I.R.) feature that complies with specific performance specifications intended to
inimize the amount of regenerant brine and water used in its operation.
m
hese softeners have a rated softener efficiency of not less than 3,350 grains of total hardness exchange per pound
T of salt (based on sodium chloride) and shall not deliver more salt than its listed rating or be operated at a sustained
aximum service flow rate greater than their listed rating. These softeners have been proven to deliver soft water
m for at least ten continuous minutes at the rated service flow rate. The rated salt efficiency is measured by laboratory tests described in NSF/ANSI Standard 44. These tests represent the maximum possible efficiency that the system can achieve. Operational efficiency is the actual efficiency after the system has been installed. It is typically less than the rated efficiency, due to individual application factors including water hardness, water usage, and other con­taminants that reduce a softener's capacity.
Model NST30ED NST45ED1 NST70ED1
Model Code SR30 SR45 SR70
11,800 @ 2.3 lbs.
Rated Softening Capacity (Grains @ Salt Dose)
Rated Efficiency (Grains/Pound of Salt @ Minimum Salt Dose)
Water Used During Regeneration @ Minimum Salt Dose
Total Water Used Per Regeneration @ Maximum Salt Dose
Rated Service Flow Rate 7.3 gpm 10.0 gpm 13.5 gpm
Amount of High Capacity Ion Exchange Resin 0.78 cu. ft. 1.26 cu. ft. 1.94 cu. ft.
Pressure Drop at Rated Service Flow 15.0 psig 11.2 psig 15.0 psig
Intermittent Flow rate @ 15 psi* 7.3 gpm 12.1 gpm 13.5 gpm
Water Supply Max. Hardness 90 gpg 120 gpg 120 gpg
Water Supply Max. Clear Water Iron 8 ppm** 12 ppm** 19 ppm**
Water Pressure Limits (minimum / maximum) 20 - 125 psi***
Water Temperature Limits (minimum / maximum) 40 - 120 °F
Minimum Water Supply Flow Rate 3 gpm
Maximum Drain Flow Rate 2.0 gpm 2.0 gpm 3.0 gpm
25,300 @ 7.4 lbs.
30,200 @ 12.5 lbs.
5,090 @ 2.3 lbs. 5,070 @ 2.6 lbs. 5,080 @ 4.1 lbs.
3.2 gal. /
1,000 grains
39.5 gallons 56.0 gallons 101 gallons
13,300 @ 2.6 lbs. 35,700 @ 9.9 lbs.
45,300 @ 17.2 lbs.
4.1 gal. /
1,000 grains
20,800 @ 4.1 lbs. 55,100 @ 15.2 lbs. 70,000 @ 26.4 lbs.
4.3 gal. /
1,000 grains
*Intermittent flow rate does not represent the maximum service flow rate used for determining the softeners’ rated
capacity and efficiency. Continuous operation at flow rates greater than the service flow rate may affect capacity and efficiency performance.
**Capacity to reduce clear water iron is substantiated by laboratory test data. State of Wisconsin requires addi-
tional treatment if water supply contains clear water iron exceeding 5 ppm.
***Canada working pressure limits: 1.4 - 7.0 kg/cm
These systems conform to NSF/ANSI 44 for the specific performance claims as verified and substantiated by
test data.
Variable Salt Dose: The salt dose is selected by the electronic controls at regeneration time based on the amount
needed.
2
.
3
18"
DIA.
39"
C
14"
3-3/4"
OUTLET
INLET
INLET -
OUTLET
A
B
Dimensions
A
INLET -
OUTLET
B
E
ominal Resin
D
OUTLET
INLET
18”
dia.
N Tank Size
Dimension A
Dimension B
Dimension C
Dimension D
Dimension E
NST30ED NST45ED1 NST70ED1
” dia.
8
x 40”
8-3/4” 50” 65-3/4”
4
41-1/4” 41-1/4” 57”
8-1/4” dia. 10-1/2” dia. 12-1/4” dia.
3-3/8” 3-3/4” 3-3/4”
11-1/2” 14” 14”
0” dia.
1
x 40”
2” dia.
1
x 54”
C
39”
FIG. 2
= The water softener requires a minimum water flow of 3 gallons per minute at the inlet. Maximum allowable inlet
water pressure is 125 psi. If your house water pressure is over the maximum, install a pressure reducing valve in the water supply pipe to the system (Adding a pressure reducing valve may reduce the flow). If your home is equipped with a back flow preventer, an expansion tank must be installed in accordance with local codes and laws.
= The water softener works on 24V DC electrical power, supplied by a direct plug-in power supply (included). Be
sure to use the included power supply and plug it into a nominal 120V, 60 Hz household outlet that is in a dry location only, grounded and properly protected by an overcurrent device such as a circuit breaker or fuse.
= Do not use this system to treat water that is microbiologically unsafe or of unknown quality without adequate dis-
infection upstream or downstream of the system.
European Directive 2002/96/EC requires all electrical and electronic equipment to be disposed of accord-
Before You Start
ing to Waste Electrical and Electronic Equipment (WEEE) requirements. This directive or similar laws are in place nationally and can vary from region to region. Please refer to your state and local laws for prop­er disposal of this equipment.
4
Installation Requirements
LOCATION REQUIREMENTS
Consider all of the following when selecting an installa­tion location for the water softener.
= Do not locate the water softener where freezing
temperatures occur. Do not attempt to treat water over 120ºF. Freezing temperatures or hot water damage voids the warranty.
= To condition all water in the home, install the water
softener close to the water supply inlet, and upstream of all other plumbing connections, except outside water pipes. Outside faucets should remain on hard water to avoid wasting conditioned water and salt.
= A nearby drain is needed to carry away regenera-
tion discharge (drain) water. Use a floor drain, laundry tub, sump, standpipe, or other options (check your local codes). See "Air Gap Requirements" and "Valve Drain Requirements" sections.
= The water softener works on 24V DC electrical
power, supplied by a direct plug-in power supply (included). Provide nearby a 120V, 60 Hz electrical outlet, in accordance with national and local codes.
= Always install the water softener between the water
inlet and water heater. Any other installed water conditioning equipment should be installed between the water inlet and water softener (See Figure 4 below).
= Avoid installing in direct sunlight. Excessive sun
heat may cause distortion or other damage to non­metallic parts.
PLUMBING CODES
All plumbing must be completed in accordance with national, state and local plumbing codes.
In the state of Massachusetts: The Commonwealth of Massachusetts plumbing code 248-CMR shall be adhered to. A licensed plumber shall be used for this installation.
AIR GAP REQUIREMENTS
A drain is needed for regeneration water (See Figure
3). A floor drain, close to the water softener, is pre­ferred. A laundry tub, standpipe, etc. are other drain options. Secure valve drain hose in place. Leave an air gap of 1-1/2” between the end of the hose and the drain. This gap is needed to prevent backflow of sewer water into the water softener. Do not put the end of the drain hose into the drain.
1-1/2”
air gap
FLOOR DRAIN
Drain Hose
1-1/2”
air gap
Drain Hose
1-1/2”
air gap
LAUNDRY TUBSTANDPIPE
Drain Hose
FIG. 3
Cold Water
to House
Hot Water
to House
THE PROPER ORDER TO INSTALL WATER TREATMENT EQUIPMENT
Untreated Water to
Outside Faucets
Water
Heater
Water
Softener
Optional
Sediment
Filter
5
Pressure
City Water Supply
Tank
Well Water Supply
OR
Well
Pump
FIG. 4
Soft
W
ater
Typical Installation Illustrations
MA
I
N
W
A
T
ER
PI
PE
CROSSOVER
se if water supply flows from the left.
Hard
Water
U
Include single or 3-valve bypass.
120V, 60 Hz Outlet
1” NPT Sweat Adaptor (2) not included
1” NPT Installation Adaptor (2) *
O-ring Seal (2) *
Bypass Valve *
Valve INLET
Clip (4) *
Hard
Hard Water to
outside faucets
Water
From
Softener
Outlet
To Softener Inlet
INSTALLATION USING 3-VALVE BYPASS
MA
IN
WA
T
E
R
PIPE
Soft
Water
BYPASS
Valve
OUTLET
Valve
INLET Valve
Soft
ater
W
Water
Hard
Models NST45ED1 & NST70ED1
1” NPT Sweat Adaptor (2) not included
Bypass Valve *
Valve INLET
* Included with softener. Pipe and
Model NST30ED
fittings supplied by installer.
For soft water SERVICE:
- Open the inlet and out­let valves
- Close the bypass valve
For hard water BYPASS:
- Close the inlet and out­let valves
- Open the bypass valve
6
1” NPT Sweat
Adaptor (2)
not included
Clip (2) *
1” NPT Installation Adaptor (2) * not included w/ NST30ED
O-ring Seal (2)
Valve INLET
FIG. 5
Installation Instructions
1. TURN OFF WATER SUPPLY
a. Close the main water supply valve near the well
pump or water meter.
b. Shut off the electric or fuel supply to the water
heater.
c. Open high and low faucets to drain all water from
the house pipes.
2. INSTALL BYPASS VALVE AND/OR PLASTIC INSTALLATION ADAPTORS:
a. If installing a single bypass valve, push the bypass
valve, with lubricated o-ring seals in place, into the valve inlet and outlet ports (See Figures 5 & 7A/7B).
- OR -
b. If installing a 3-valve bypass system, slide plastic
installation adaptors, with lubricated o-ring seals in place, into the valve inlet and outlet ports (See Figures 5 & 7A).
c. Make sure the turbine and support are firmly in
place in the valve outlet, as shown in Figure 8. Blow into the valve port and observe the turbine for free rotation.
d. Snap the two large plastic clips in place on the inlet
and outlet ports, from the top, down (See Figure 9). Make sure they snap into place. Pull on the bypass valve, or installation adaptors, to make sure they are held securely in place.
3. MOVE THE UNIT INTO INSTALLATION POSITION
a. Move the water softener into the desired location.
Set it on a solid, level surface.
IMPORTANT: Do not place shims directly under the
salt storage tank to level the softener. The weight of the tank, when full of water and salt, may cause the tank to fracture at the shim.
Clip (2)
INLET
Clip (2)
INLET
Turbine
Clip (2)
Models NST45ED1
& NST70ED1
OUTLET
Turbine
Support
Plastic
nstallation
i
adaptors
FIG. 7A
Model NST30ED
OUTLET
Turbine
Support
Bypass Valve
FIG. 7B
Turbine Support Assembly
Valve Outlet
Bypass Valve
SINGLE BYPASS VALVE
Pull out for “Service” (Soft water)
Push in for “Bypass”
FIG. 6
FIG. 8
Clip
END VIEWSIDE VIEW
O-ring
7
Bypass valve or
plastic adaptor
FIG. 9
Installation Instructions
urn the bypass
T
valve downward if
onnecting to floor
c
level plumbing
OUTLET
INLET
4. COMPLETE INLET AND OUTLET PLUMBING
Pipe fittings must be 3/4” minimum.
Use:
= Copper pipe = Threaded pipe = PEX (Crosslinked Polyethylene) pipe = CPVC plastic pipe = Other pipe approved for use with potable water
IMPORTANT: Do not solder with plumbing attached to
installation adaptors and single bypass valve. Soldering heat will damage the adaptors and valve.Measure, cut, and loosely assemble pipe and fittings from the main water pipe to the inlet and out­let ports of the water softener valve. Be sure to keep fittings fully together, and pipes squared and straight.
Be sure hard water supply pipe goes to the water sof­tener valve inlet side.
NOTE: Inlet and outlet are marked on the water sof-
tener valve. Trace the water flow direction to be sure hard water is to inlet.
IMPORTANT: Be sure to fit, align and support all
plumbing to prevent putting stress on the water softener valve inlet and outlet. Stress from misaligned or unsupported plumbing may cause damage to the valve.
Complete the inlet and outlet plumbing for the type of pipe you will be using.
FIG. 10
5. COLD WATER PIPE GROUNDING
The house cold water pipe (metal only) is often used as a ground for the house electrical system, The 3­valve bypass type of installation, shown in Figure 5, will maintain ground continuity. If you use a plastic bypass valve at the unit, continuity is broken. To restore the ground, do the following:
Purchase and securely install two grounding clamps and a #4 copper wire across the location where the softener will be, tightly clamping it at both ends, as shown in Figure 11.
NOTE: Check local plumbing and electrical codes for
proper installation of grounding. The installa­tion must conform to them.
Ground Wire (not included)
Clamp
(2 - not included)
FIG. 11
6. INSTALL VALVE DRAIN HOSE
a. Measure, cut to needed length and connect the 3/8"
drain line (provided) to the water softener valve drain fitting. Use a hose clamp to hold the hose in place.
NOTE: Avoid drain hose
runs longer than 30 feet. Avoid elevat­ing the hose more than 8 feet above the floor. Make the valve drain line as short and direct as possible.
NOTE: If codes require a
rigid drain line see Figure 13.
b. Route the drain hose or
copper tubing to the floor drain. Secure drain hose. This will prevent “whipping'' dur­ing regenerations. See “Air Gap Requirements" section.
1-1/2”
Air Gap
Drain Fitting
on valve
Valve Drain Hose
To Floor Drain
FIG. 12
8