- Hemo Pod/HemoMed, CO catheter and thermistor
are not included.
Cardiac output kit Ohmeda7265163
Including: - CO intermediate cable, 1 m (3.3 ft)
- CO catheter cable
- CO thermistor cable, Ohmeda Hemo Pod/HemoMed,
CO catheter and thermistor are not included.
B
Pod kit with sensor7265114
etCO
2
Including: - etCO
2
Pod
- Pod connection cable, 3 m (9.8 ft)
- Universal pole mount
- etCO
- etCO
capnostat III sensor with 2.4 m (7.9 ft) cable
2
airway adapter, adult, reusable
2
- calibration and reference cell
- cable clip, 5 pcs.
C
module kit with sensor 7265122
etCO
2
Including: - etCO
- etCO
- etCO
capnostat III sensor with 2.4 m (7.9 ft) cable
2
airway adapter, adult, reusable
2
module
2
- calibration and reference cell
- cable clip, 5 pcs.
D
etCO
and respiratory mechanics kit,7497709
2
adult
Including: - etCO
and Respiratory mechanics Pod
2
- Pod connection cable, 3 m (9.8 ft)
- Universal pole mount
- etCO
- etCO
capnostat III sensor with 2.4 m (7.9 ft) cable
2
airway adapter, adult, reusable
2
- calibration and reference cell
- cable clip, 5 pcs.
- respiratory mechanics combined flow/CO
sensor
2
adult/paediatric disposable, 10 pcs.
AB
CD
9
10
ECG
1.2 ECG
1.2.1 MonoLead T-connector
MonoLead is a one-wire lead-set solution, patented from
Dräger, that is particularly well suited for monitoring in
the ED, OR and PACU units. The single tangle-proof lead
set accommodates standard electrodes while eliminating
the tangled mess that frequently occurs with traditional
multi-lead sets.
Gamma / Gamma XL
Gamma X XL
Delta / Delta XL
Kappa
Kappa XLT
Vista
Vista XL
A
B
Features:
- Ideal for both adult and paediatric patients
- MonoLead is compatible with all Infinity patient monitors.
- Fast and easy to apply with clearly labeled,
color-coded snaps
- More comfortable for patients, incorporates Dräger
Medical’s patented Z-Snap™ zero-insertion force
electrode snaps
- Flexible, durable and easy to clean
- Bright green color makes the cable easy to identify
even under a sheet.
Note: Not for use with Infinity Telemetry.
A
ECG MonoLead 3, T-connectorMS14555
IEC1 (European color code), 2 m (6.6 ft)
ECG MonoLead 3, T-connectorMS14556
IEC2 (AHA/US color code), 2 m (6.6 ft)
B
ECG MonoLead 5, T-connectorMS14559
IEC1 (European color code), 2.5 m (8.2 ft)
ECG MonoLead 5, T-connectorMS14560
IEC2 (AHA/US color code), 2.5 m (8.2 ft)
C
ECG MonoLead 6, T-connectorMS14683
IEC1 (European color code), 2.5 m (8.2 ft)
D
ECG MonoLead 6, T-connectorMS14682
IEC2 (AHA/US color code), 2.5 m (8.2 ft)
•••••••
•••••••
•••••••
•••••••
•••••••
•••••••
C
D
11
ECG
Gamma / Gamma XL
Gamma X XL
Delta / Delta XL
Kappa
Kappa XLT
Vista
Vista XL
A
•••••••
•••••••
•••••••
B
•••••••
•••••••
•••••••
C
•••••••
A
Adapter MonoLead to MultiMed 5 Pod MS14679
Adapter is required to connect the
MonoLead 3/5 to the MultiMed 5 Pod.
Adapter MonoLead to MultiMed 6 Pod MS14680
Adapter is required to connect the
MonoLead 3/5 to the MultiMed 6 Pod.
Telemetry Lead AdapterMS14681
Adapter used to connect TruST Lead set to
an Infinity Telemetry Transmitter. Not to be used
to connect TruST Leads to MultiMed Pods.
Not for use in the operating room.
1.2.2 MonoLead Dual Pin
B
ECG MonoLead 3, Dual PinMS16160
IEC1 (European color code), 2 m (6.6 ft)
ECG MonoLead 3, Dual PinMS16233
IEC2 (AHA/US color code), 2 m (6.6 ft)
C
ECG MonoLead 5, Dual PinMS16161
IEC1 (European color code), 2.5 m (8.2 ft)
ECG MonoLead 5, Dual PinMS16229
IEC2 (AHA/US color code), 2.5 m (8.2 ft)
12
••••
••••
ECG MonoLead 5, chest, Dual PinMS16232
IEC1 (European color code), 2.5 m (8.2 ft)
ECG MonoLead 5, chest, Dual PinMS16230
IEC2 (AHA/US color code), 2.5 m (8.2 ft)
ECG
Gamma / Gamma XL
Gamma X XL
Delta / Delta XL
Kappa
Kappa XLT
Vista
Vista XL
1.2.3 ECG Leads T-connector
ECG 3-lead, grabber, T-connector,MS16159
IEC1 (European color code)
ECG 3-lead, grabber, T-connector,MS16231
IEC2 (AHA/US color code)
A
ECG 5-lead, grabber, T-connector,MS16158
IEC1 (European color code)
A
ECG 5-lead, grabber, T-connector,MS16546
IEC2 (AHA/US color code)
ECG 6-lead, grabber, T-connector,MS16157
IEC1 (European color code)
ECG 6-lead, grabber, T-connector,MS16547
IEC2 (AHA/US color code)
A
•••••••
•••••••
•••••••
•••••••
•••••••
•••••••
13
ECG
Gamma / Gamma XL
Gamma X XL
Delta / Delta XL
Kappa
Kappa XLT
Vista
Vista XL
A
•••••••
•••••••
•••••••
B
•••••••
•••••••
•••••••
C
1.2.4 ECG Leads Dual Pin and electrodes
A
ECG 3-lead grabber set, 1 m (3.3 ft), 5956433
IEC1 European
ECG 3-lead grabber set, 1 m (3.3 ft),5956441
IEC2 AHA/US
European color code (IEC1 European) or AHA/US
color code (IEC2 AHA/US) - For disposable electrodes.
To be used in the OR only when the ECG ESU block is
connected to the MultiMed Pod.
B
ECG 5-lead grabber set, 1 m (3.3 ft),5956466
IEC1 European
ECG 5-lead grabber set, 1 m (3.3 ft),5956458
IEC2 AHA/US
European color code (IEC1 European) or AHA/US
color code (IEC2 AHA/US) - For disposable electrodes.
Can be used in the OR only when the ECG ESU block
is connected to the MultiMed Pod.
C
ECG 6-lead grabber set, 1 m (3.3 ft),5956482
IEC1 European
ECG 6-lead grabber set, 1 m (3.3 ft),5956474
IEC2 AHA/US
European color code (IEC1 European) or AHA/US
color code (IEC2 AHA/US) - For disposable electrodes.
Can be used in the OR when the ECG ESU 6 block is
connected to the MultiMed Pod.
14
ECG
Gamma / Gamma XL
Gamma X XL
Delta / Delta XL
Kappa
Kappa XLT
Vista
Vista XL
A
ECG ESU block, 5-lead5947226
Electrosurgical interference suppression filter. The
ECG ESU BLOCK provides ECG electrosurgical unit
noise suppression and burn protection. This small
plastic unit plugs between standard shielded white
ECG Lead wires and the MultiMed 5 or MultiMed 6
Pod. It can be used with 3 or 5 lead wire ECG Lead
sets. Self seating design. Including: - Storage holster
that can be mounted on any suitable flat surface.
B
ECG ESU block, 6-lead 7486140
The ECG ESU BLOCK provides ECG electrosurgical
unit noise suppression and burn protection. This small
plastic unit plugs between standard shielded white
ECG Lead wires and the MultiMed 6 Pod. It can be
used with 3, 5 or 6 wire ECG Lead sets. Self seating
design. Including: - Storage holster that can be
mounted on any suitable flat surface.
C
ECG 5-lead C grabber set, 1.5 m (4.9 ft), 5956508
IEC1 European
ECG 5-lead V grabber set, 1.5 m (4.9 ft), 5956490
IEC2 AHA/US
European color code (IEC1 European) or AHA/US
color code (IEC2 AHA/US) - For disposable electrodes.
Not for OR use. Chest leads used with MultiMed 12 and
ECG 5-lead grabber set IEC1 European (5956466).
•••••••
A
•••••••
B
••••
••••
C
15
ECG
A
B
Gamma / Gamma XL
Gamma X XL
Delta / Delta XL
Kappa
Kappa XLT
Vista
Vista XL
••••
•••••••
••••••••
TruST Telemtry
A
ECG C/V 5-lead, no connect plug5734400
For blocking unused leads when using a
MultiMed12 Pod.
B
ECG 5-lead limb, radiotranslucent lead, 5734418
1.5 m (4.9 ft), IEC2 AHA/US
AHA/US color code - Will not show up on X-ray.
C
ECG electrodes, disposable, 50 pcs. 4527750
General purpose electrodes for adults.
Pre-gelled, not for ambulatory use.
C
••••••••
D
••••••••
••••••••
••••••••
E
••••••••
••••••••
F
1.2.5 Telemetry grabber sets
Infinity TruST Lead sets can also be used in combination
with MultiMed 6T and MultiMed 6T/OR.
Lenght 686 mm (27 inch). Shielded, not for OR use.
Lead set for disposable electrodes.
D
3-lead grabber set, TruST Telemetry, 7499804
IEC1 European (European color code)
D
3-lead grabber set, TruST Telemetry,7499812
IEC2 AHA/US (AHA/US color code)
E
5-lead grabber set, TruST Telemetry, 7499820
IEC1 European (European color code)
Adapter is required to connect the MonoLead 3/5
to the MultiMed 5 Pod.
Adapter MonoLead to MultiMed 6 Pod MS14680
Adapter is required to connect the MonoLead 3/5
to the MultiMed 6 Pod.
Telemetry Lead adapterMS14681
Adapter used to connect TruST Lead set to an Infinity
Telemetry Transmitter. Not to be used to connect TruST
Leads to MultiMed Pods. Not for use in the operating
room.
Transmitter Analog ECG cable 4316621
Used to connect Infinity Telemetry or TruST Telemetry
Transmitter to MultiMed Pod for Lead II display on any
Infinity bedside monitor.
•••••••
A
•••••••
•••••••
•••••••
17
ECG
Gamma / Gamma XL
Gamma X XL
Delta / Delta XL
Kappa
Kappa XLT
Vista
Vista XL
A
•••••••
•••••••
B
•••••••
••••
C
••••
D
1.2.6 Pods and accessories
A
MultiMed 5 Pod, 1.5 m (4.9 ft)5950196
MultiMed 5 Pod, 2.5 m (8.2 ft)3368391
Multiparameter cable to monitor 3- or 5-lead ECG,
impedance respiration, two temperatures
(modular monitors only) and SpO2.
B
MultiMed 6 Pod, 2.5 m (8.2 ft)5191221
Multiparameter cable to monitor dual chest lead,
6-lead ECG, impedance respiration, two temperatures
(modular monitors only) and SpO2.
C
MultiMed 12 Pod5589663
Multiparameter cable to monitor 12 lead ECG and
SpO
Infinity SC 9000 requires ARIES 12 Lead ST
2
processor option. Infinity SC 7/8/9000XL requires
ARIES 12 Lead ST option. Including:
- Pod connection cable, 3 m (9.8 ft)
- Mounting band.
D
MultiMed 12 Pod mounting band 5202747
Flexible mounting band to attach MultiMed 12 Pod
to bed rails and other mounting surfaces.
18
ECG
Gamma / Gamma XL
Gamma X XL
Delta / Delta XL
Kappa
Kappa XLT
Vista
Vista XL
A
Pod connection cable, 0.3 m (11.9 in)7257988
Pod connection cable, 3 m (9.8 ft) 3368425
Pod connection cable, 5 m (16.4 ft)5195198
Connects Hemo2, Hemo4, MultiMed 12,
tpO
/tpCO2and etCO2Pods to Infinity modular monitors.
2
Connects etCO
Not for SC 5000/600X.
B
Pod mount5598128
Mount for securing the MultiMed 5/6 and
NeoMed Pods.
C
MultiMed Pod holderMP00721
for MultiMed 5, MultiMed 6, and NeoMed Pod.
Fits to all mounts. Turnable 180°.
Neonatal electrodes with attached lead wire 100
packages of 3 electrodes. Use in conjunction with
adapter pins (5194779).
B
Adapter pin, neonatal electrodes, 10 pcs.5194779
For connection of neonatal electrodes with
1.5 mm (0.06 in) safety pin connectors to the
MultiMed Pod and ECG intermediate cables.
C
ECG adapter cable, NeoMed Pod, 5592162
1.5 m (4.9 ft)
3-lead ECG adapter cable connecting neonatal ECG
Leads to NeoMed Pod. Not for OR use.
D
NeoMed Pod, 2.5 m (8.2 ft) 5590539
Multiparameter cable to monitor neonatal
3-lead ECG, impedance respiration, SpO
two temperatures (Infinity modular monitors only),
and FiO
Not for use during electrosurgery.
Including: - Pod mount.
Neonatal NeoMed + SpO
+ NBP monitoring kit
For further information see 1.1 Accessory kits.
E
MultiMed Pod holderMP00721
for MultiMed 5, MultiMed 6 and NeoMed Pod.
Fits to all mounts. Turnable 180°.
(Infinity modular monitors only).
2
2
,
2
7265312
E
20
212223
SpO
2
A
1.3 SpO
1.3.1 Dräger sensors
1.3.1.1 Reusable sensors
A
1.3.1.2 Disposable sensors
B
C
D
E
F
G
2
Dräger SpO
High quality reusable SpO
for use on adult and paediatric patients.
Validated for use with all Dräger patient monitors.
Patient weight: > 30 kg (66 Lbs).
Dräger SpO
Patient weight: > 30 kg (66 Lbs). Non sterile.
Box of 24 adult sensors.
Dräger SpO
Patient weight: > 30 kg (66 Lbs). Non sterile.
Box of 24 adult sensors.
Dräger SpO
Patient weight: 10-50 kg (22-110 Lbs). Non sterile.
Box of 24 paediatric sensors.
Dräger SpO
Patient weight: 10-50 kg (22-110 Lbs). Non sterile.
Box of 24 paediatric sensors.
Dräger SpO
Patient weight: 3-20 kg (6.6-44 Lbs). Non sterile.
Box of 24 infant sensors.
Dräger SpO
Patient weight: < 3 kg (6.6 Lbs). Non sterile.
Box of 24 neonatal sensors.
finger sensor, adult MS13235
2
sensor, adult, vinylMS16449
2
sensor, adult, foamMS16445
2
sensor, paediatric, vinylMS16448
2
sensor, paediatric, foamMS16444
2
sensor, infant, clothMS16447
2
sensor, neonatal, clothMS16446
2
finger sensor
2
Gamma / Gamma XL
Gamma X XL
Delta / Delta XL
Kappa
Kappa XLT
Vista
Vista XL
••••••••
•••••••
•••••••
•••••••
•••••••
•••••••
•••••••
+
2
MicrO
B
C
D
E
F
G
Dräger SpO2 sensor Connectivity Flow Chart
MS 16449
SpO2 sensor, adult, vinyl
24
S 16445
SpO2 sensor, adult, foam
MS 16448
SpO2 sensor, ped., vinyl
S 16444
SpO2 sensor, ped., foam
MS 16447
SpO2 sensor, infant, cloth
MS 16446
SpO2 sensor, neonatal, cloth
SpO
2
A
1.3.2 Masimo sensors, cables and accessories
1.3.2.1 Masimo reusable sensors
A
Masimo SpO
Adult finger clip style sensor.
Patient weight: > 30 kg (66 Lbs). Recommended
monitoring site: ring or middle finger of non-dominant hand.
B
Masimo SpO
Paediatric/adult Slender finger clip style sensor.
Patient weight: 10-50 kg (22-110 Lbs).
Recommended monitoring site: ring or middle
finger of non-dominant hand.
C
Masimo SpO
Multisite reusable sensor V shaped multisite
reusable sensor with a 90 cm (35.4 in) cable
that can be used on patients > 1 kg (2.2 Lbs).
The sensor is attached using either an adhesive
attachment wrap or a non-adhesive foam wrap.
Patient weight: > 1 kg (2.2 Lbs).
D
Masimo Cleanshield wrap for LNOP YI5702218
Cleanshild multisite wrap. Box with 100
replacement wraps for SpO2LNOP YI sensor.
E
Masimo Multisite wrap for SpO
Standard multisite wrap. Box with 100
replacement wraps for SpO2LNOP YI sensor.
Masimo Petite wrap for SpO
Standard petite wrap. Box with 100
replacement wraps for SpO2LNOP YI sensor.
F
Masimo Foam wrap, neonatal, 7496891
12 pcs.
Set of 12 replacement foam wraps
for SpO
sensor LNOP DCI7270312
2
sensor LNOP DCIP7270304
2
sensor LNOP YI 7497014
2
LNOP YI7496917
2
LNOP YI7496909
2
LNOP YI sensor.
2
Gamma / Gamma XL
Gamma X XL
Delta / Delta XL
Kappa
Kappa XLT
Vista
Vista XL
••••••••
••••••••
••••••••
••••••••
••••••••
••••••••
••••••••
+
2
MicrO
B
C
D
E
F
25
SpO
2
+
2
Gamma / Gamma XL
Gamma X XL
Delta / Delta XL
Kappa
Kappa XLT
Vista
Vista XL
MicrO
A
••••••••
••••••••
B
••••••••
••••••••
••••••••
C
D
A
Masimo sensor LNOP TI7497006
Ear reusable sensor.
Patient weight: > 30 kg (66 Lbs).
Recommended monitoring site: ear lobe or pinna.
Unique hook limits constriction of blood flow.
B
Masimo posey wrap, 7496933
12 pcs.
Set of posey wrap for neonatal sensor.
C
Masimo sensor tapes, 7496925
100 pcs.
Replacement tapes for neonatal sensors.
D
Masimo accessory clothing clip, 7496883
5 pcs.
Replacement clothing clips for the sensor.
E
Masimo adhesive square, 7496875
12 pcs.
Set of 12x 12 replacement adhesive squares
for the sensor.
E
26
SpO
2
1.3.2.2 Masimo disposable sensors
A
Masimo SpO
20 pcs.
Adult single patient adhesive sensor. Patient weight:
> 30 kg (66 Lbs). Recommended monitoring site: ring
or middle finger of non-dominant hand. Latex free.
B
Masimo SpO
20 pcs.
Paediatric/slender digit single patient adhesive sensor.
Patient weight: 10-50 kg (22-110 Lbs). Recommended
monitoring site: ring or middle finger of non-dominant
hand. Latex free.
C
Masimo SpO
Neonatal single patient adhesive sensor. Patient weight:
< 10 kg (22 Lbs). Recommended monitoring site:
- For infants < 3 kg (6.6 Lbs): across the foot or
alternatively across the palm & back of hand.
- For infants > 3 kg (6.6 Lbs): the thumb or the great toe.
Latex free.
D
Masimo SpO
Neonatal preterm single patient adhesive sensor.
Patient weight: < 1 kg (2.2 Lbs). Recommended
monitoring site: across the foot or alternatively
across the palm & back of hand. Latex free.
E
Masimo Posey wrap for NeoPt,5701935
12 pcs.
Set of posey wrap for neonatal sensor.
F
Masimo tapes for NeoPt,7496925
100 pcs.
Set of replacement tapes for neonatal sensors.
SpO
pack LNOP Adt + Pdt7496941
2
Adult/paediatric sensor sample pack for use
in mixed wards. Contains:
- (3) LNOP Adt adhesive sensors (7496990)
- (1) LNOP Pdt adhesive sensor (7496982).
SpO
pack LNOP Neo + NeoPt7496958
2
Neonatal sensor sample pack for use
on all neonates. Contains: