COUNTERTOP PASTRY DISPLAY
MN094SGG/0
Installation, Operation and
Maintenance Instructions
INSPECTION
When the equipment is received, all items should be carefully checked against the bill of lading to insure all
crates and cartons have been received. All units should be inspected for concealed damage by uncrating the
units immediately. If any damage is found, it should be reported to the carrier at once, and a claim should be
filed with the carrier. This equipment has been inspected and tested in the Nor-Lake Manufacturing Facility
and has been crated in accordance with transportation rules and guidelines. Manufacturer is not responsible
for freight loss or damage.
GENERAL INFORMATION
PHYSICAL SPECIFICATIONS
Exterior Dimensions: 27" w x 22"d x 46"h
Volume: 8.2 Cubic Feet
Pass-Thru: Two doors in front and rear
Front Door Opening: 25" x 27"
Rear Door Opening: 25" x 23"
Window Opening: 26" x 19"
Price Tag Holder: Holds 25-5/8" x 1-1/4" Tag
Transparency Cutouts: Front & Back 10" x 23"
Sides 10" x 18"
ELECTRICAL
Check the proposed outlet to be used to insure that the voltage, phase, and current carrying capacity of the
circuit from the electrical panel correspond to the requirements of the cabinet. NEVER use an extension cord
to run power to the unit. All inter-wiring between the electrical panel and the cabinet must be done in
accordance with the National Electric Code and all state and local codes. Refer to serial tag for all pertinent
electrical information.
MN094SGG/0 16/3 Cord 115/60/1
Unit Model Type of Connection Voltage/Hz/Ph
© 2004 Nor-Lake, Inc. 10/04 097059
GENERAL OPERATION
PREPARATION FOR USE
The handles on the doors of the cabinet are mounted on the inside of the glass doors for shipping purposes
only. Remove the screw and washer from the handle. Next, move the handle from inside the cabinet and
mount it on the outside of the glass door using the same screw and washer. Be sure not to over tighten.
After the Pastry Display is placed in its permanent location, it must be sealed to the countertop.
countertop is a requirement of NSF. This can be accomplished by applying silicone around the base of the
cabinet with an approved sealant such as Dow Corning #732 silicone.
Sealing to the
GENERAL MAINTENANCE
SQUARING GLASS DOORS
Read all directions first.
The ideal vertical gap between the closed doors is approximately 1/8". If the gap is consistent all the way
down the doors and the tops of the doors are flush, the doors are square. If the gap widens at one end and/or
the tops of the doors are not flush, the doors will need to be adjusted.
The steps below should be used when loosening the hinges to square the doors. Following these steps will
reduce the risk of breakage and will allow more control when making small adjustments. A Phillips
screwdriver will be needed to adjust the doors.
Steps to loosen hinges:
1. Open the door 90° so that it is straight out from the cabinet.
2. Ensure that both of the screws in the hinge are snug, which will reduce the possibility of the door
releasing unexpectedly.
3. Loosen the outside screw (screw A) so that it will allow the glass to move for adjustment in the next step.
The door should not move at this point.
4. While holding the door securely, loosen screw B just enough to allow for movement of the door. Move the
door in the direction required and retighten screw B.
5. After making the adjustment, close the door to check if it is square.
6. If square, tighten screw A. If not, repeat steps 4 and 5 as necessary until the doors are square.
GLASS DOOR REMOVAL
Read all directions first.
1. Open the door 90° so that it is straight out from the cabinet.
2. While holding the door securely, use a Phillips screwdriver to loosen both screws on the top hinge so they
will not resist movement.
3. The hinge will fall out of position once the top of the door is free from the hinge.
4. Lift the door up and out so as to disengage the bottom hinge pin from the cabinet.
GLASS DOOR INSTALLATION
Read all directions first.
1. Remove the top hinge from the door if it is attached.
2. With the bottom hinge attached to the door, lift the door and insert the bottom hinge pin into position.
3. Insert the top hinge pin into place and hold until the top of the door can be slid into the hinge. Once the
top of the door is in the hinge, it will hold the hinge in place.
4. Tighten both screws on the top hinge.
5. Follow the steps under Squaring Glass Doors to make adjustments as needed.