Model NRCP1112 and NRCP982 Series
Residential Condensing Tankless Water Heater
Specification Sheet
• Standard Input- Gas consumption ranges:
NRCP1112 : 18,000 BTUh to 199,000 BTUh
NRCP982 : 18,000 BTUh to 180,000 BTUh
• Capacity Range- Flow rates of 0.5 GPM up to 11.1 GPM (NRCP1112)
and 10.1 GPM (NRCP982)
• Compact Design- ANSI Z21.10.3/CSA 4.3 certified design that can be wall-mounted
indoors
• Durable Steel Casing with Polyester Coating
• Heat Exchanger- Manufactured with STS 304 stainless steel
• Venting Options- For indoor installation only. Convertible to Single Vent (-SV) with the
use of conversion kit (#SV-CK-3)
• Direct Electronic Ignition
• Energy Factor- 0.95(NG) 0.95(LP)
• Temperature Controls- Includes remote thermostat that can precisely adjust the
output temperature from 100°F to 140°F with the capability to display temperatures in
both °C and °F
• Power Cord Installation Kit- 6’ power cord is included
• Safety Devices- Flame Sensor, Overheat Cut off Limit Switch, Gas Leak Detector Sensor,
Water Leak Detector Sensor, Exhaust Temperature Sensor, Water Temperature Sensor
• Recirculation Mode- Includes built in recirculation pump to provide Internal and
External Pre-Heat Recirculation
• 12-Year* Limited Heat Exchanger Warranty for Residential Use
• 5-Year Limited Parts Warranty
• Approvals- UPC**, ETL, NSF, Low NOx Approved by SCAQMD [<14 ng/j or 20ppm]
DV Model
NRCP1112-DV
NRCP982-DV
3” PVC Termination (#VK3-H-PVC)
Vertical Adapter Set (#VK3-PVC-VAS)
PVC Terminal (#PRC-1)
Neutralizer (NC-1) (For 1 Water Heater)
Horizontal Hood Termination (#PVT-HL)
Isolation Valves (# IK-WV-200-1)
Vent Screens with Finishing (2”) (After Market)
PVC Reducer Bushing (3in X 2in) (After Market)
SV Conversion Kit (#SV-CK-3) 90 Elbow with
Inlet Screen
LOW-LEAD
*Heat Exchanger warranty is maintained at 12 years, when used in a single family dwelling in accordance with the installation Manual. Refer to Noritz
Limited Warranty for complete coverage details.
** This product complies with California AB 1953 Low Lead Law and Section 1417(d) of the Safe Drinking Water Act
NORITZ AMERICA CORPORATION
11160 Grace Avenue, Fount ain Valley, CA 92708 Tel. 1-866-7NORITZ www.noritz.com
Temperature Rise (°F)
GPM)
NRCP1112-DV
NRCP982-DV
Flow Rate
(
Dimensions
Flow Rates
30 40 45 50 60 70 80 90 100
8.6 7.7 6.3 5.4 4.7 4.211.1 9.6 3.7
9.6 8.7 7.8 7.0 5.8 4.9 4.2 3.8 3.5
Model Name
Weight
Operating Pressure
Gas Supply Pressure
Water Holding Capacity
Water Inlet
Connection
Sizes
Hot Water Outlet
Gas Inlet
Condensate Drain
Recirculation Return
Power
Supply
Freeze Protection
Temperature Settings
40
35
30
25
20
15
Pressure loss [psi]
10
5
0
0 1 2 3 4 5 6 7 8
Bypass Closed
Pressure Loss
Flow rate [GPM]
Specifications
NRCP1112
NG: 3.5” - 10.5” LP: 8.0” - 14.0”
°F Mode
°C Mode
Normal Temp: 100-120°F, High Temp : 125-140°F (In 5°F intervals) (9 Options)
Normal Temp: 38-49°C, High Temp : 51.5-60°F (In equivalent 5°F intervals) (9 Options)
Bypass Open
85 (pounds)
15 - 150 psi
Under 2 Gallon
3/4"
3/4"
3/4"
1/2" Threaded
3/4"
120VAC 60Hz
172W(82W+90W_PUMP)Consumption
42°F (5.5°C) - 46°F (8°C)
90
80
70
60
50
40
30
Pressure loss [Ft. of Head]
20
10
0
NRCP982
ut notice.