Noritz NRC98-DV User Manual

Model NRC98(GQ-C2857WS US) Series
Residential Condensing Tankless Water Heater
Specification Sheet
- Gas consumption ranges from 16,000 BTUh to
180,000 BTUh
- Flow rates from 0.5 gpm up to 9.8 gpm
- ANSI Z21.10.3/CSA 4.3 certified design that can be
wall-mounted indoors or outdoors
- Manufactured with commercial grade copper,
25% thicker piping than standard models
- Available as an Outdoor (requires no venting) or indoor Direct Vent (-DV) model which includes special plastic flue adapters that are compatible with both 3” or 4” Schedule 40 and 80 PVC/CPVC pipe. The DV model can also be converted to a non-direct vent (SV) model with the use of a Conversion Kit (#SV-CK-3)
OD Model
DV Model
- Two identical units can be linked together by using
the optional Quick Connect Cord (#QC-2) for twice the hot water capacity
- 0.93 (NG) 0.93 (LP)
- Includes remote thermostat that can precisely adjust the output temperature from 115°F to 140°F with the capability to display temperatures in both °C and °F
- 6’ power cord is included with -DV models only
- Flame Sensor, Overheat Prevention Device,
Lightning Protection Device, Freeze Protection, Condensate Overfill
Temperature Lockout, High Elevation Adjustment,
Condensate Overflow Monitoring System, Service Reminder Function,
New Scale Detection Function
- CSA, UPC**, NSF, Low NOx Approved by SCAQMD [<14ng/J or 20ppm]
LOW-LEAD
CERTIFIED
R
NRC98____
OD (Outdoor Vent)
DV (Direct Vent)
Horizontal Hood Termination (#PVT-HL)
3” PVC Termination (#VK3-H-PVC)
Birdscreen for 3” PVC/CPVC (#VT3-PVCS)
Birdscreen for 4” PVC/CPVC (#VT4-PVCS)
Condensate Neutralizer (#NC-1)
Isolation Valves (#IK-WV-200-1-(SW / TH)-LF)
Pipe Cover (#PC-3S)
Quick Connect Cord (#QC-2)
* Heat Exchanger warranty is maintained at 12 years or 6500 operational hours, whichever occurs first, when used in a single family dwelling in conjunction with a controlled recirculation system (an aquastat being the minimum pump control requirement) in accordance with the Installation Manual. Refer to the Noritz Limited Warranty for complete coverage details ** This product complies with California AB 1953 Low Lead Law and section 1417(d) of the Safe Drinking Water Act
NORITZ AMERICA CORPORATION
11160 Grace Avenue, Fountain Valley, CA 92708 Tel. 1-866-7NORITZ www.noritz.com
0.4" (10mm)
2.4" (61mm)
1.6" (40mm)
9.4" (240mm)
5.5" (140mm)
1.1" (28mm)
Ø 4.5" (114mm)
Ø 3.5" (89.5mm)
AIR INLET
18.3" (464mm)
17.6" (448mm)
5.9" (150mm)
9.1" (232mm)
Dimensions
Ø 4.5" (114mm) Ø 3.5" (89.5mm)
FLUE COLLAR
18.3" (464mm)
17.6" (448mm)
10.5" (267mm)
3.9" (99mm)
2.4" (61mm)2.1" (53mm)
2.0" (50mm)
6.6" (168mm)
5.9" (149mm)
(VIEW FROM TOP)
14.0" (355mm)
12.6" (320mm)
7.0" (179mm)
3.6" (93mm)
2.2" (55mm)
4.1" (104mm)
5.6" (142mm)
6.1" (155mm)
23.1" (586mm)
0.4" (10mm)
SIDE VIEW
24.2" (615mm)
WIRING THROUGHWAY
CONDENSATE DRAIN
WATER DRAIN VALVE
WATER DRAIN VALVE (WATER FILTER)
HOT WATER OUTLET WATER DRAIN VALVE
Temperature Rise (°F)
Flow Rate (GPM)
30 40 45 50 60 70 80 90 100
9.8 8.4 7.5 6.7 5.6 4.8 4.2 3.7 3.4
70
60
50
40
30
Pressure Loss (psi)
20
10
FRONT VIEW
BOTTOM VIEW
WIRING THROUGHWAY (AC120V)
GAS INLET
COLD WATER INLET
Flow Rates
Pressure Loss
OD Model
HOT WATER OUTLET (3/4")
CONDENSATE DRAIN (1/2")
WIRING THROUGHWAY
2.3" (66mm)
5.4" (137mm)
HEIGHT OF EACH FITTING FROM BOTTOM OF CASE
CONDENSATE DRAIN
HOT WATER OUTLET
COLD WATER INLET
160
140
120
100
80
60
40
20
9.6" (244mm)
Pressure Loss (Ft. of head)
WIRING THROUGHWAY (AC120V) -OD Model Only
GAS INLET (3/4")
WIRING THROUGHWAY
COLD WATER INLET (3/4")
NRC98-OD
0.8" (20 mm)
1.8" (45 mm)
1.9" (49 mm)
2.2" (56 mm)
(AC120V)
< inch (mm)>
NRC98-DV
0.9" (24 mm)
1.8" (45 mm)
1.9" (49 mm)
2.2" (56 mm)GAS INLET
0
0
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 Flow Rate (GPM)
Specifications
Model Name
Weight
Water Holding Capacity
Connection Sizes
Water Inlet 3/4"
Hot Water Outlet 3/4"
Gas Inlet
Condensate Drain 1/2"
Power
Supply
Freeze Protection
Temperature Settings
Default Temperature Options
°F Mode
°C Mode
°F Mode
°C Mode
NRC98OD(GQ-C2857WS US)
57 (pounds)
0.5 Gallon (1.8 L)
3/4"
3/4"
3/4"
1/2"
120VAC (60Hz), less than 4 amperes
NG: 64W LP: 68W Free ze Preventi on 203W
Outdoor: -4
°F
115-140°F (In 5°F intervals) (6 Options)
46, 47, 48, 50, 55, 60°C (6 Options)
120, 125, 130, 140°F (Default is 120°F)
50, 52, 55, 60°C (Default is 50°C)
NRC98DV(GQ-C2857WS-FF US)
58 (pounds)
0.5 Gallon (1.8 L)
3/4"
Indoor: -30
°F
ut notice.
W312 noitneverP ezeerF W87 :PL W37 :GNnoitpmusnoC
Rev. 04/16