V6 Syringe Drive Pump
The VersaPump 6 is a programmable precision liquid metering instrument with non-volatile user program memory and system input/output (I/O). The V6 is designed with the flexibility and versatility to meet a variety of system configurations. It can be used as a stand alone controller, or integrated into system
configurations. The module is capable of simple closed loop control of an external quantity or process without the need of an external controller for direction.
Mechanically, the syringe pump is driven via stepper motor and precision ball screw. It has a 60mm stroke and is available in three resolutions. The pump can be coupled with a variety of valves and syringes, as well as PC board selections, to meet specific needs.
Pump communications are compatible with other Kloehn devices.
Physical
Height
10"
Width
2.55"
Depth
4.75" (face plate to back plate) 4.9" to card edge
Weight
5.14 lbs.
Environmental
Operating Temperature
32°F to 131°F (0°C to 55°C)
Operating Humidity
5 to 95% RH, non-condensing at 131°F (55°C)
Storage Temperature
13°F to 185°F (–25° to 85°C)
WEEE & RoHS compliant
Mechanical
Operation
Any orientation
Mounting Holes
Top and bottom as well as on the face plate
Resolutions Available
(12000; 24000; and 48000 increments)
Speed
(Max. – 10000 steps/sec.; min. 60 steps / sec.) (Default – 5000 steps/sec.)
Syringe Size
25ul to 50ml
Valve Type
2 way to 12 way
Available with no valve; solenoid valve; or rotary valve
PC board choices:
Base board (sensor array and motor pin out only - no motor drivers or control electronics). Driver board (sensor array and motor drivers only, no control electronics).
Driver & Control boards (fully functional motor drivers and control electronics).
Card-edge connector
Integrated RS232
Integrated power filter
Multiple valve choices
Including no valve & solenoid valve
1/10 Stroke Dispenses |
Full Stroke Dispenses |
Precision: 0.10% CV, 0.20% max. |
0.007% CV, 0.0092% max. |
Accuracy: 0.20% CV, 0.60% max. |
—— |
Interface
RS-485 or RS-232 communications Data terminal or OEM protocol 1200 to 38.4K baud, 8 data bits,
1 stop bit, no parity, half duplex Three inputs, three output ports Digital voltmeter
Switched and wired device address
Power
Operation
24V (with a maximum power voltage ripple of 720mv peak-to-peak).
Power Consumption
40 watts, 11 watts idle.
4/13 |
Our policy is one of continued research and development. We therefore reserve the right to amend, |
without notice, the specifications given in this document. |
|
|
© Norgren Kloehn, Inc. 2012 |
PDS-0005 REV 7
V6 Syringe Drive Pump
Syringe Pump:
VERSAPUMP 6 AVAILABLE SCENARIO CHART
|
RESOLUTION |
|
|
VALVE FEATURE |
|
|
DRIVER & CONTROL FEATURE |
PUMP |
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
48K |
|
24K |
|
12K |
NONE |
SOLENOID |
|
ROTARY |
BASIC |
|
DRIVER BOARD |
DRIVER & |
PT# |
|
|
|
|
CONTROL BOARD |
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
X |
|
|
|
|
X |
|
|
|
X |
|
|
|
54000 |
X |
|
|
|
|
X |
|
|
|
|
|
X |
|
54001 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
X |
|
|
|
|
X |
|
|
|
|
|
|
X |
55002 |
X |
|
|
|
|
|
X |
|
|
X |
|
|
|
54010 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
X |
|
|
|
|
|
X |
|
|
|
|
X |
|
54011 |
X |
|
|
|
|
|
X |
|
|
|
|
|
X |
55012 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
X |
|
|
|
|
|
|
|
X |
X |
|
|
|
54020 |
X |
|
|
|
|
|
|
|
X |
|
|
X |
|
54021 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
X |
|
|
|
|
|
|
|
X |
|
|
|
X |
55022 |
|
|
X |
|
|
X |
|
|
|
X |
|
|
|
54100 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
X |
|
|
X |
|
|
|
|
|
X |
|
54101 |
|
|
X |
|
|
X |
|
|
|
|
|
|
X |
55102 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
X |
|
|
|
X |
|
|
X |
|
|
|
54110 |
|
|
X |
|
|
|
X |
|
|
|
|
X |
|
54111 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
X |
|
|
|
X |
|
|
|
|
|
X |
55112 |
|
|
X |
|
|
|
|
|
X |
X |
|
|
|
54120 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
X |
|
|
|
|
|
X |
|
|
X |
|
54121 |
|
|
X |
|
|
|
|
|
X |
|
|
|
X |
55122 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
X |
X |
|
|
|
X |
|
|
|
54200 |
|
|
|
|
X |
X |
|
|
|
|
|
X |
|
54201 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
X |
X |
|
|
|
|
|
|
X |
55202 |
|
|
|
|
X |
|
X |
|
|
X |
|
|
|
54210 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
X |
|
X |
|
|
|
|
X |
|
54211 |
|
|
|
|
X |
|
X |
|
|
|
|
|
X |
55212 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
X |
|
|
|
X |
X |
|
|
|
54220 |
|
|
|
|
X |
|
|
|
X |
|
|
X |
|
54221 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
X |
|
|
|
X |
|
|
|
X |
55222 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Decal (23279) is optional, add to order as required. 3-way solenoid valve supplied with pumps conÿgured for solenoid valve.
Precision Syringe Pump V6P:
VERSAPUMP 6 AVAILABLE SCENARIO CHART
RESOLUTION |
VALVE FEATURE |
DRIVER & CONTROL FEATURE |
PUMP |
|
|
|
|
|
|
48K |
24K |
ROTARY |
DRIVER & CONTROL BOARD |
PT# |
|
|
|
|
|
X |
|
X |
X |
55023 |
|
X |
X |
X |
55123 |
|
|
|
|
|
4/13 |
Our policy is one of continued research and development. We therefore reserve the right to amend, |
without notice, the specifications given in this document. |
|
|
© Norgren Kloehn, Inc. 2012 |
PDS-0005 REV 7