Norgren R83 User Manual

See Section ALE-24 for Accessories
ALE-10-4
Littleton, CO USA Phone 303-794-2611 www.norgren.com
R83
Underwriters Laboratories, Inc. listed (file number
SA1089) for use with air, argon, carbon dioxide, helium, krypton, neon, nitrogen, xenon. For use with other gases, including oxygen, consult Norgren.
Non-relieving and relieving models. Relieving models
allow reduction of outlet pressure even when the system is dead-ended
Two high pressure inlet ports and two regulated
pressure outlet ports
Diametrically opposite inlet ports provide easy
manifolding of several regulators
Easily replaceable valve cartridge contains valve,
valve seat, valve spring, and filter element
UL Listed Pressure Regulator for
Industrial Cylinder Gas 1/4" PTF Port Size
Ordering Information. Models listed include PTF threads, relieving diaphragm, 5 to 125 psig (0.3 to 8.5 bar) outlet pressure adjustment
range†, and without gauge.
Port Model Flow * scfm dm3/s() Weight lb (kg) 1/4" R83-200-RNLA 11 (5.2) 1.3 (0.59)
Alternative Models
-
AN
2 0
-
8 0R 3
Outlet Pressure Adjustment Ranges
Substitute 2 to 50 psig (0.1 to 3.5 bar) E 5 to 125 psig (0.3 to 8.5 bar) L 10 to 175 psig (0.7 to 12 bar) N
Diaphragm Substitute Relieving R Non relieving N
* Approximate flow with 1000 psig (69 bar) inlet pressure, 60 psig (4 bar) set pressure and a 5 psig (0.35 bar) droop from set. † Outlet pressure can be adjusted to pressures in excess of, and less than, those specified.Do not use these units to control pressures outside of the specified ranges.
R83 Pressure Regulator for Industrial Cylinder Gas
ALE-10-5
All Dimensions in Inches (mm)
Littleton, CO USA Phone 303-794-2611 www.norgren.com
Technical Data
Fluid: Air, argon, carbon dioxide, helium, krypton, neon, nitrogen, and xenon.For
use with other gases, including oxygen, consult Norgren.Do not use the R83 regulator in beverage dispensing applications.Other Norgren regulators (R81 for soft drink, R82 for beer, R84 for carbonators) are available for use in
dispensing systems. Maximum pressure: 3000 psig (207 bar) Operating temperature: -30° to 140°F (-34° to 60°C) *
* Fluid must be dry enough to avoid ice formation at temperatures below 35°F (2°C).
Typical flow at 1000 psig (69 bar) inlet pressure, 60 psig (4 bar) set pressure and a
droop of 5 psig (0.35 bar) from set: 11 scfm (5.2 dm3/s)
Materials
Body: Brass Bonnet: Zinc Cartridge valve:Teflon, brass, stainless steel Diaphragm: Acetal and nitrile Seals: Nitrile
PORT SIZE: 1/4" SPRING RANGE: 5 to 125 psig (0.3 to 8.5 bar) INLET PRESSURE: 1000 psig (69 bar)
012345dm
3
/s
FLOW
0 2 4 6 8 10 12 scfm
OUTLET PRESSURE
8
6
4
2
0
bar
100
80
60
40
20
0
psig
FLOW CHARACTERISTICS - CO
2
Typical Performance Characteristics
30°
1.66 (42)
1.90 (48)
4.41 (112)
2.10 (53)
0.40 (10)
Mounting Holes (2 Places)
0.18" (4.6mm) dia. by 0.39 (10mm) deep. Use 10-32 thread forming screws.
Service Kits
Item Type Part number Service kits
Diaphragm, relieving 570-51 Diaphragm, non relieving 570-10 Valve cartridge 5086-55
Valve cartridge includes the sealed cartridge and cartridge o-ring.
Warning
These products are intended for use with industrial compressed air, argon, carbon dioxide, helium, krypton, neon, nitrogen, and xenon.Do not use these products where pressures and temperatures can exceed those listed under
‘Technical Data’.
Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult Norgren.
Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes.The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure.
System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided.
System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products.
Loading...