Air line equipment
R24 Micro-Trol Pressure
Regulator
1/4" to 1-1/4" ports
ISO Symbol
Relieving
High flow regulator with exceptional
high relief flow
Adjusting knob can be set in the field
to stop at some maximum pressure
setting or some minimum pressure
setting
Easy to adjust even at high output
pressures
Balanced valve minimizes effect of
variations in inlet pressure on outlet
pressure
Constant bleed feature provides
maximum sensitivity to system
changes
Relieving feature allows reduction of
downstream pressure when the
system is dead-ended
Full flow gauge ports
Technical data
Fluid:
Compressed air
Maximum inlet pressure:
300 psig (20 bar)
Operating temperature:
0° to 150°F (-20° to 80°C)*
* Air supply must be dry enough to avoid ice formation at
temperatures below 35°F (2°C).
Maximum bleed rate at 50 psig
(3.5 bar) outlet pressure:
0.031 scfm (0.016 dm3/s) †
† Maximum bleed rate occurs under dead-end (no flow)
conditions.
Port sizes:
Main Gauge
1/4" 1/4"
3/8" 3/8"
1/2", 3/4", 1", 1-1/4" 1/2"
Thread type: PTF, ISO G, or Rc
Materials
Body, top cap: Zinc
Main valve, adjusting screw: Brass
Pilot valve, relief valve: Acetal
Elastomers: Nitrile
Bottom Plug: Acetal
Ordering Information.
Models listed are constant bleed units with relieving diaphragm, 10 to 125 psig (0.7 to 8 bar) outlet pressure adjustment
range, and PTF threads.
Port Size Model Flow (scfm) Weight lb (kg)
1⁄2" R24-400-RGLA 200 1.79 (0.81)
1-1⁄4" R24-A00-RGLA 700 2.65 (1.20)
Alternative Models
R24 ˙00 R˙˙˙
Port Size Substitute
1/4" 2
3/8" 3
1/2" 4
3/4" 6
1" 8
1-1/4" A
* Outlet pressure can be adjusted to pressures in excess of, and less than, those specified. Do not use these units to control
pressures outside of the specified ranges.
** A factory installed gauge is only available with PTF threads (A in last position of model number). If a gauge is desired with ISO
threads (B or G in last position), order the desired gauge and appropriate reducing bushing from Accessories.
Threads Substitute
PTF A
ISO G parallel G
Outlet Pres Adj. Ranges* Substitute
5 to 30 psig (0.3 to 2 bar) C
5 to 60 psig (0.3 to 4 bar) F
10 to 125 psig (0.7 to 8 bar) L
10 to 250 psig (0.7 to 17 bar) S
Gauge Substitute
With G**
Without N
ALE-62
www.norgren.com/usa

FLOW CHARACTERISTICS
0 20 40 60 80 100 dm3/s
AIR FLOW
0 40 80 120 160 200 240 scfm
8
6
4
2
0
OUTLET PRESSURE
bar g
psig
PORT SIZE: 1/2"
INLET PRESSURE: 150 psig (10 bar)
RANGE: 10 to 125 psig (0.7 to 8.6 bar)
100
80
60
40
20
0
120
FLOW CHARACTERISTICS
0 50 100 150 200 250 300 dm3/s
AIR FLOW
0 100 200 300 400 500 600 700 scfm
8
6
4
2
0
bar g
100
80
60
40
20
0
psig
PORT SIZE: 1-1/4"
INLET PRESSURE: 150 psig (10 bar)
RANGE: 10 to 125 psig (0.7 to 8.6 bar)
RELIEF FLOW CHARACTERISTICS
0 10 20 30 40 50 dm3/s
AIR FLOW
0 20 40 60 80 100 120 scfm
OUTLET PRESSURE
8
6
4
2
0
bar g
100
80
60
40
20
0
psig
TYPICAL ALL MODELS
INLET PRESSURE: 200 psig (14 bar g)
R24 Micro Trol Pressure Regulator
1/4" to 1-1/4" ports
Typical Performance Characteristics
RANGE: 10 to 232 psi (0.7 to 16 bar)
2.70 (69)
3.42 (87)
4.83 (123)
2.15 (55)
Dimensions in inches (mm)
Panel mounting hole diameter: 1.26" (32 mm)
Maximum panel thickness: 0 to 0.12" (3 mm)
Service Kits
Item Type Part number
Service kit 1⁄4, 3⁄8, 1⁄2 5292-52
Service kit 3⁄4, 1, 1-1⁄4 5292-53
Service kits include seals, main valve and spring.
2.91 (74)
3.58 (91)
5.37 (136)
3.65 (93)
ALE-63